UniFuse 12401803Recalls & reported problems

Angiodynamics, Inc. · UniFuse Infusion System w/ Cooper Wire · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI H787124018030), received between Sep 20, 2023 and Mar 18, 2024 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 2 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component5

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • Foreign Body In Patient2

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 18, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    AN END USER REPORTED AN ISSUE WITH A CATHETER FROM A UNI 5FX45CMX15CM UNIFUSE SYSTEM KIT. THEY INSERTED THE CATHETER AND INFUSED THE MEDICINE. AFTER 45 MINUTES THEY BROUGHT THE PATIENT INTO THE ROOM, AND THEY STARTED THE PROCEDURE. AS THEY ATTEMPTED TO REMOVE THE CATHETER, ONE OF THE MARKERS WAS LEFT BEHIND IN THE PATIENT. THE MARKER WAS IN THE FOREARM OF THE PATIENT, AND RETRIEVED BY FLUSHING IT OUT WHEN THE SHEATH WAS PULLED OUT.

    Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions

    MAUDE report 18920661 ↗
  • MalfunctionMar 18, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    AN END USER REPORTED AN ISSUE WITH A CATHETER FROM A UNI 5FX45CMX15CM UNIFUSE SYSTEM KIT. THEY INSERTED THE CATHETER AND INFUSED THE MEDICINE. AFTER 45 MINUTES THEY BROUGHT THE PATIENT INTO THE ROOM, AND THEY STARTED THE PROCEDURE. AS THEY ATTEMPTED TO REMOVE THE AN END USER REPORTED AN ISSUE WITH TWO CATHETERS FROM TWO DIFFERENT UNI 5FX45CMX15CM UNIFUSE SYSTEM KITS DURING THE SAME PROCEDURE. WE DID A THROMBECTOMY ON A 73-YEAR-OLD FEMALE. WE USED TWO 15CM UNIFUSE CATHETERS. AS WE ATTEMPTED TO REMOVE THE CATHETER, ONE OF THE MARKERS WAS LEFT BEHIND IN THE PATIENT. WE PUT THE 7F SHEATH IN THE ARM AND WHEN WE REMOVED THE DILATOR IT WAS PUSHED TIGHTLY OVER THE TIP SO WE WERE ABLE TO RETRIEVE IT WITH NO TROUBLE. THE PROCEDURE WAS COMPLETED WITH A NEW OF THE SAME DEVICE. THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS OR HARM BECAUSE OF THIS INCIDENT.

    Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions

    MAUDE report 18920658 ↗
  • MalfunctionOct 31, 2023Detachment of Device or Device Component; Detachment of Device or Device Component

    AN END USER REPORTED AN ISSUE WITH A UNI (B)(4) UNIFUSE SYSTEM. DURING A PROCEDURE, THE MARKERS CAME OFF OF THE DEVICE, WHILE IT WAS BEING INSERTED INTO THE PATIENT. THE MARKERS WERE ABLE TO BE RETRIEVED, ALONG WITH THE CATHETER, AND THE PROCEDURE WAS COMPLETED WITH ANOTHER SAME DEVICE. THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS OR HARM AS A RESULT OF THIS INCIDENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18041478 ↗
  • MalfunctionSep 20, 2023Detachment of Device or Device Component; Detachment of Device or Device Component

    A REGIONAL BUSINESS MANAGER REPORTED AN END USER EXPERIENCED AN ISSUE WHEN USING A UNIFUSE 5FX45CMX15CM UNIFUSE SYSTEM. WHEN THEY REMOVE THE CATHETER TO BEGIN THE CASE, THE MARKER COMES OFF THE CATHETER AND NEEDS TO BE RETRIEVED FROM INSIDE THE PATIENT, VIA SNARE. ULTIMATELY, THE PROCEDURE WAS COMPLETED WITH THIS DEVICE AND THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS OR HARM DUE TO THIS INCIDENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17783089 ↗
  • MalfunctionSep 20, 2023Detachment of Device or Device Component; Detachment of Device or Device Component

    A REGIONAL BUSINESS MANAGER REPORTED AN END USER EXPERIENCED AN ISSUE WHEN USING A UNIFUSE 5FX45CMX15CM UNIFUSE SYSTEM. WHEN THEY REMOVE THE CATHETER TO BEGIN THE CASE, THE MARKER COMES OFF THE CATHETER AND NEEDS TO BE RETRIEVED FROM INSIDE THE PATIENT, VIA SNARE. ULTIMATELY, THE PROCEDURE WAS COMPLETED WITH THIS DEVICE AND THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS OR HARM DUE TO THIS INCIDENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17783086 ↗

Other Catheter, continuous flush devices

All Catheter, continuous flush devices →