Skip to content

Vortex SSAX-16-IRecalls & reported problems

Navilyst Medical, Inc. · Vortex TR Single Titanium Port System with Attached 9.6F x 53cm Silicone Catheter · Class 2 · Implant

All models of Vortex (14)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI H787SSAX16I0), received between Jun 20, 2018 and Feb 26, 2026 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).

1 other recall cover devices cleared under the same FDA submission (K032557); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component2
  • Difficult to Remove1
  • Fracture1
  • Infusion or Flow Problem1
  • Migration1
  • Migration or Expulsion of Device1

Patient problems

  • Device Embedded In Tissue or Plaque1
  • Foreign Body In Patient1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 26, 2026Fracture; Detachment of Device or Device Component; Infusion or Flow Problem

    ON OR ABOUT (B)(6) 2007, PLAINTIFF UNDERWENT PLACEMENT OF DEFENDANTS' VORTEX PORT CATHETER DEVICE, WITH MODEL NUMBER SSAX-16-1, AND LOT NUMBER 27839. THE VORTEX WAS IMPLANTED BY DR. (B)(6), AT (B)(6) HOSPITAL (B)(6). ON OR ABOUT (B)(6) 2007, PLAINTIFF PRESENTED TO (B)(6) HOSPITAL (B)(6) FOR REMOVAL OF THE VORTEX GIVEN THE DEVICE WAS NO LONGER NEEDED AND WAS NOT FLUSHING PROPERLY. ON OR ABOUT (B)(6) 2007, DR. (B)(6) ATTEMPTED TO REMOVE THE VORTEX DEVICE, AND WHILE HE WAS ABLE TO REMOVE THE PORT BODY ITSELF, HE DISCOVERED THAT THE CATHETER PORTION OF THE DEVICE HAD FRACTURED AND MIGRATED. PLAINTIFF UNDERWENT IMAGING, WHICH CONFIRMED A FRAGMENT OF THE FRACTURED CATHETER REMAINED IN HIS BODY. ON OR ABOUT (B)(6) 2007, PLAINTIFF PRESENTED TO (B)(6) HOSPITAL IN (B)(6) TO UNDERGO RETRIEVAL OF THE FRACTURED CATHETER FRAGMENT. THE RETRIEVAL PROCEDURE WAS PERFORMED BY DR. (B)(6), AND SHE WAS ABLE TO SUCCESSFULLY RETRIEVE THE ENTIRE CATHETER FRAGMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24465480 ↗
  • InjuryNov 30, 2023Difficult to Remove; Detachment of Device or Device Component; Migration; Difficult to Remove; Detachment of Device or Device Component; Migration

    A LEGAL FIRM REPORTED AN ADVERSE EVENT ASSOCIATED WITH A TRIUMPH VORTEX PORT ATT W/ 10F INTRO KIT PG. THE FOLLOWING WAS REPORTED: -ON OR ABOUT (B)(6) 2021, PLAINTIFF UNDERWENT IMAGING, WHICH DEMONSTRATED A CATHETER FRACTURE. THE FRAGMENT WAS POSITIONED IN THE BASE OF PLAINTIFF'S RIGHT ATRIUM AND RIGHT VENTRICLE. - ON OR ABOUT (B)(6) 2021, PLAINTIFF PRESENTED HERSELF TO (B)(6) MEDICAL CENTER IN (B)(6) FOR FRAGMENT RETRIEVAL. AFTER MULTIPLE ATTEMPTS, PLAINTIFF'S MEDICAL TEAM WERE UNABLE TO RETRIEVE THE CATHETER FRAGMENT. -ON OR ABOUT (B)(6) 2021, PLAINTIFF UNDERWENT A SECOND SURGERY TO REMOVE THE CATHETER FRAGMENT FROM HER RIGHT ATRIUM AND RIGHT VENTRICLE. AFTER MULTIPLE ATTEMPTS, PLAINTIFF'S MEDICAL TEAM WERE ONCE AGAIN UNABLE TO RETRIEVE THE FRAGMENT. PLAINTIFF WAS REFERRED TO AN INTERVENTIONAL CARDIOLOGIST FOR FURTHER ASSESSMENT AND TREATMENT. -ON OR ABOUT (B)(6) 2021, PLAINTIFF PRESENTED HERSELF TO (B)(6) HOSPITAL IN (B)(6) FOR FRAGMENT RETRIEVAL. AFTER MULTIPLE ATTEMPTS, PLAINTIFF'S MEDICAL TEAM WERE UNABLE TO RETRIEVE THE CATHETER FRAGMENT. -ON OR ABOUT (B)(6) 2022, PLAINTIFF RETURNED TO (B)(6) FOR A FOLLOW-UP APPOINTMENT, WHERE HER MEDICAL TEAM DETERMINED THAT THE RISKS OF FUR

    Patient problems: Foreign Body In Patient

    MAUDE report 18242402 ↗
  • InjuryJun 20, 2018Migration or Expulsion of Device; Migration or Expulsion of Device

    AS REPORTED, DURING REMOVAL OF AN IMPLANTED PORT AT (B)(6) MEDICAL CENTER THE CATHETER FRACTURED. THE PATIENT HAD TO BE TRANSFERRED TO ANOTHER FACILITY BECAUSE NO INTERVENTIONAL RADIOLOGIST WAS AVAILABLE AT (B)(6) MEDICAL CENTER. NO PATIENT INJURY WAS REPORTED. THE USED DEVICE HAS BEEN DISCARDED AT THE HOSPITAL.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 7618692 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K032557. One submission often covers many models, so check the product and lot details in each record.

  • Z-0403-2011 · Sep 27, 2010 · Terminated
    Vortex TR, AngioDynamics, Inc., One Horizon Way, Manchester, GA 31816

Other PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR devices

All PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page