Vortex SSDX-16-IRecalls & reported problems

Navilyst Medical, Inc. · Vortex TR Single Titanium Port System with Attachable 9.6F x 70cm Silicone Catheter · Class 2 · Implant

All models of Vortex (14)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI H787SSDX16I0), received between Aug 29, 2023 and Oct 23, 2024 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (3 reports).

1 other recall cover devices cleared under the same FDA submission (K951814); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 2 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component3
  • Device Dislodged or Dislocated1
  • Material Separation1

Patient problems

  • Foreign Body In Patient3
  • Arrhythmia2
  • Chest Pain2
  • Unspecified Heart Problem2
  • Emotional Changes1
  • Implant Pain1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 23, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    ON (B)(6) 2018, A VORTEX PORT CATHETER, LOT #5131154 WAS IMPLANTED IN PLAINTIFF'S LEFT SIDE CHEST. THE PROCEDURE WAS PERFORMED BY DR. (B)(6) AT (B)(6). PLAINTIFF'S PORT CATHETER WAS REMOVED ON OR ABOUT (B)(6) 2023, BY DR. (B)(6), AT (B)(6) HOSPITAL, AS IT WAS NO LONGER NEEDED. AT THE TIME OF THE SURGICAL REMOVAL ON (B)(6) 2023, DR. (B)(6) HAD DIFFICULTY REMOVING THE VORTEX PORT. DURING THE REMOVAL, A PORTION OF THE VORTEX CATHETER BROKE AND REMAINED IN PLAINTIFF'S BODY, UNBEKNOWNST TO DR. (B)(6) OR PLAINTIFF. FOR SEVERAL WEEKS/MONTHS THEREAFTER, PLAINTIFF EXPERIENCED LEFT SIDE CHEST PAIN, PLEURITIC, AND PALPATIONS WHICH WOULD WORSEN WHEN PLAINTIFF LAID ON HIS LEFT SIDE. PLAINTIFF WAS TREATED FOR CHEST PAIN, PALPITATIONS AND SHORTNESS OF BREATH ON (B)(6) 2023 AT THE (B)(6) HOSPITAL. IN THE COURSE OF HIS TREATMENT IN (B)(6) 2023, A CT WAS PERFORMED WHICH SHOWED "CALCIFIED RIGHT ATRIAL MASS SEEN ON ECHO SHOWING UP ON CT AS RETAINED FRAGMENT IN LEFT BRACHIOCEPHALIC VEIN". DUE TO THE LOCATION OF THE RETAINED FRAGMENT AND THE RISK TO PLAINTIFF FOR AN ATTEMPTED REMOVAL OF THE FRAGMENT, THE DECISION WAS MADE TO LEAVE THE RETAINED VORTEX FRAGMENT IN PLAINTIFF'S BODY. TO DATE, THE RETAINED F

    Patient problems: Arrhythmia; Chest Pain; Foreign Body In Patient; Unspecified Heart Problem

    MAUDE report 20516097 ↗
  • MalfunctionOct 22, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    ON (B)(6) 2018, A VORTEX PORT CATHETER, LOT #5131154 WAS IMPLANTED IN PLAINTIFF'S LEFT SIDE CHEST. THE PROCEDURE WAS PERFORMED BY DR. (B)(6) AT (B)(6) CENTER. PLAINTIFF'S PORT CATHETER WAS REMOVED ON OR ABOUT (B)(6) 2023, BY DR. (B)(6), AT (B)(6) HOSPITAL OF THE, AS IT WAS NO LONGER NEEDED. AT THE TIME OF THE SURGICAL REMOVAL ON (B)(6) 2023, DR. (B)(6) HAD DIFFICULTY REMOVING THE VORTEX PORT. DURING THE REMOVAL, A PORTION OF THE VORTEX CATHETER BROKE AND REMAINED IN PLAINTIFF'S BODY, UNBEKNOWNST TO DR. (B)(6) OR PLAINTIFF. FOR SEVERAL WEEKS/MONTHS THEREAFTER, PLAINTIFF EXPERIENCED LEFT SIDE CHEST PAIN, PLEURITIC, AND PALPATIONS WHICH WOULD WORSEN WHEN PLAINTIFF LAID ON HIS LEFT SIDE. PLAINTIFF WAS TREATED FOR CHEST PAIN, PALPITATIONS AND SHORTNESS OF BREATH ON (B)(6) 2023 AT THE HOSPITAL OF (B)(6). IN THE COURSE OF HIS TREATMENT IN (B)(6) 2023, A CT WAS PERFORMED WHICH SHOWED "CALCIFIED RIGHT ATRIAL MASS SEEN ON ECHO SHOWING UP ON CT AS RETAINED FRAGMENT IN LEFT BRACHIOCEPHALIC VEIN". DUE TO THE LOCATION OF THE RETAINED FRAGMENT AND THE RISK TO PLAINTIFF FOR AN ATTEMPTED REMOVAL OF THE FRAGMENT, THE DECISION WAS MADE TO LEAVE THE RETAINED VORTEX FRAGMENT IN PLAINTIFF'S BODY. TO DAT

    Patient problems: Arrhythmia; Chest Pain; Foreign Body In Patient; Unspecified Heart Problem

    MAUDE report 20509246 ↗
  • InjuryAug 29, 2023Material Separation; Detachment of Device or Device Component; Device Dislodged or Dislocated; Material Separation; Detachment of Device or Device Component; Device Dislodged or Dislocated

    (B)(4), A LEGAL GROUP, NOTIFIED ANGIODYNAMICS OF AN INCIDENT REGARDING A TRIUMPH VORTEX PORT. ON OR ABOUT (B)(6) 2018, PLAINTIFF UNDERWENT PLACEMENT OF THE TRIUMPH VORTEX PORT, DET W/10F INTRO DEVICE. THE DEVICE WAS IMPLANTED BY DR. (B)(6) , M.D., AT (B)(6) , FOR THE PURPOSE OF ONGOING CHEMOTHERAPY. ON OR ABOUT (B)(6) 2019, PLAINTIFF PRESENTED HIMSELF TO (B)(6) FOR PORT REMOVAL. PLAINTIFF'S MEDICAL TEAM DETERMINED THAT PLAINTIFF'S PORT WAS MALFUNCTIONING AND CAUSING EXTREME PAIN TO PLAINTIFF. DURING REMOVAL OF THE VORTEX PORT ON (B)(6) 2019, PLAINTIFF'S MEDICAL TEAM NOTICED THAT THE CATHETER SEGMENT APPEARED TOO SHORT. AN X-RAY WAS TAKEN, AND IT REVEALED THAT PART OF THE CATHETER BROKE OFF AND HAD TRAVELED TO PLAINTIFF'S HEART. PLAINTIFF UNDERWENT A SECOND SURGERY ON AN EMERGENCY BASIS TO REMOVE THE FOREIGN FRAGMENT FROM HIS HEART ON (B)(6) 2019. AS A RESULT OF HAVING THE VORTEX IMPLANTED, PLAINTIFF HAS EXPERIENCED SIGNIFICANT MENTAL AND PHYSICAL PAIN AND SUFFERING, HAS SUSTAINED PERMANENT INJURY, PERMANENT AND SUBSTANTIAL PHYSICAL DEFORMITY, HAS UNDERGONE CORRECTIVE SURGERIES, AND HAS SUFFERED FINANCIAL OR ECONOMIC LOSS, INCLUDING, BUT NOT LIMITED TO, OBLIGATIONS FOR MEDICAL SERVI

    Patient problems: Emotional Changes; Foreign Body In Patient; Implant Pain

    MAUDE report 17643858 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K951814. One submission often covers many models, so check the product and lot details in each record.

  • Z-0406-2011 · Sep 27, 2010 · Terminated
    Triumph-1, AngioDynamics, Inc., One Horizon Way, Manchester, GA 31816.

Other PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR devices

All PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR devices →