AngioVac H965252810Recalls & reported problems
Navilyst Medical, Inc. · AngioVac Circuit · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI H965252810), received between May 6, 2026 and May 6, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
1 other recall cover devices cleared under the same FDA submission (K142607); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component1
Patient problems
- Pulmonary Embolism1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 6, 2026Detachment of Device or Device Component
A DISTRIBUTOR REPORTED AN ISSUE WITH AN ANGIOVAC CIRCUIT WITH BUBBLE TRAP. IT WAS REPORTED THAT DURING ASSEMBLY OF THE CEC CIRCUIT FOR THROMBOASPIRATION, IT WAS FOUND THAT THE RING HAD BECOME DETACHED, PREVENTING THE NUT FROM BEING TIGHTENED AND LOOSENED TO INSERT THE MANDREL. IT WAS REPORTED THAT THIS RESULTED IN A LESS EFFECTIVE PROCEDURE AND LONGER INTERVENTION TIME. IT WAS LATER REPORTED THAT THE PATIENT EXPERIENCED AN INTRAOPERATIVE IATROGENIC PULMONARY EMBOLISM DURING THE PROCEDURE, AFTER REMOVAL OF THE ANGIOVAC CATHETER, WHEN THE CLOT BECAME DISLODGED. THROMBOASPIRATION WAS THEN PERFORMED USING AN INARI DEVICE. CURRENTLY, THE PATIENT IS IN GOOD CLINICAL HEALTH AND IS TAKING ANTICOAGULANTS FOR HER BILATERAL PULMONARY EMBOLISM. THE PHYSICIAN REPORTED THAT THERE IS NO DIRECT LINK BETWEEN THE MALFUNCTION OF THE ANGIOVAC DEVICE AND THE PATIENT ADVERSE EVENT.
Patient problems: Pulmonary Embolism
MAUDE report 25094095 ↗
FDA clearance and classification
Cleared through 510(k) K142607 on Dec 11, 2014 (decision: Substantially Equivalent). Submitted by Angiodynamics as “AngioVac Circuit”. The FDA review took 87 days. FDA record ↗
The FDA regulates product code DWE (tubing, pump, cardiopulmonary bypass) under 21 CFR 870.4390 as a Class II device. 21 CFR 870.4390 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K142607. One submission often covers many models, so check the product and lot details in each record.
- Z-1702-2016 · Mar 21, 2016 · TerminatedAngioVac Circuit Pack (Tandem Packs), REF/Catalog No. 25-187, UPN H965251870, STERILE, Rx Only, Single Use Only -- The AngioVac Circuit and AngioVac Circuit Pack are designed to be
Common questions about the AngioVac H965252810
Has the AngioVac H965252810 been recalled?
No FDA recall record in our data names this exact device identifier (DI H965252810), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.
What problems have been reported with the AngioVac H965252810?
The FDA's MAUDE database lists 1 adverse event report for this device, received on May 6, 2026. That report lists device problem “Detachment of Device or Device Component” (1); patient problem “Pulmonary Embolism” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the AngioVac H965252810?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the AngioVac H965252810 FDA approved?
It was cleared through 510(k) K142607 on Dec 11, 2014. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the AngioVac H965252810, and is it still sold?
The FDA's device database lists Navilyst Medical, Inc. as the company responsible for it (brand AngioVac, model H965252810). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other TUBING, PUMP, CARDIOPULMONARY BYPASS devices
- NA BB9L72R1Medtronic, Inc. · TUBING, PUMP, CARDIOPULMONARY BYPASS3 recalls0 reports
- NA BB8M16R3Medtronic, Inc. · TUBING, PUMP, CARDIOPULMONARY BYPASS2 recalls1 report
- NA BB8D40R3Medtronic, Inc. · TUBING, PUMP, CARDIOPULMONARY BYPASS2 recalls0 reports
- NA BB8L58R3Medtronic, Inc. · TUBING, PUMP, CARDIOPULMONARY BYPASS2 recalls0 reports
- NA BB8T77R2Medtronic, Inc. · TUBING, PUMP, CARDIOPULMONARY BYPASS2 recalls0 reports
- NA BB7P48R4Medtronic, Inc. · TUBING, PUMP, CARDIOPULMONARY BYPASS2 recalls0 reports
- NA BB7P46R4Medtronic, Inc. · TUBING, PUMP, CARDIOPULMONARY BYPASS2 recalls0 reports
- NA BB8B70R7Medtronic, Inc. · TUBING, PUMP, CARDIOPULMONARY BYPASS2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page