M-access® K-REAMER A11MA02501512Recalls & reported problems
MAILLEFER INSTRUMENTS HOLDING Sàrl · Endodontic Instrument · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI J003A11MA025015121), received between Apr 16, 2024 and Apr 16, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 16, 2024Break; Break
IN THIS EVENT IT IS REPORTED THAT A K-REAMER M-ACCESS 25MM FILE BROKE DURING USE. THE BROKEN PARTS COULD NOT BE RETRIEVED. NO INJURY.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 19116798 ↗
Other REAMER, PULP CANAL, ENDODONTIC devices
- M-access® K-REAMER A11MA02102012MAILLEFER INSTRUMENTS HOLDING Sàrl · REAMER, PULP CANAL, ENDODONTIC4 reports
- M-access® K-REAMER A11MA02101012MAILLEFER INSTRUMENTS HOLDING Sàrl · REAMER, PULP CANAL, ENDODONTIC1 report
- M-access® K-REAMER A11MA02503012MAILLEFER INSTRUMENTS HOLDING Sàrl · REAMER, PULP CANAL, ENDODONTIC1 report
- M-access® K-REAMER A11MA02501012MAILLEFER INSTRUMENTS HOLDING Sàrl · REAMER, PULP CANAL, ENDODONTIC1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page