ADVANCE® KSPP1512Recalls & reported problems
Microport Orthopedics Inc. · Class 2 · Implant
All models of ADVANCE (147)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI M684KSPP15121), received between Jul 3, 2019 and Mar 24, 2020 — classified as 3 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information1
- Loss of Osseointegration1
- Unstable1
Patient problems
- No Information2
- Pain1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMar 24, 2020Loss of Osseointegration; Loss of Osseointegration
ALLEGEDLY, LOOKS LIKE THE TIBIAL BASE PLATE IS LOOSENING , PATELLA WAS SPINNING AND FEMUR COULD NOT BALANCE IN FLEXION AND EXTENSION SO FEMUR HAD TO GO ADDITIONAL INFORMATION: LEFT KNEE.
Patient problems: No Information
MAUDE report 9873242 ↗InjuryDec 23, 2019Unstable; Unstable
ALLEGEDLY, INSTABILITY THE AREA AROUND THE IMPLANTS WAS ALL BACK, 'POSSIBLE METALLOSIS" CULTURES TAKEN: LATERAL CONDYLE POSTERIORLY HAD SIGNIFICANT WEAR ON POLY, FEMUR WORE THROUGH POLY AND WAS METAL ON METAL W/ BASE PLATE.
Patient problems: No Information
MAUDE report 9512676 ↗InjuryJul 3, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
ALLEGEDLY TIBIAL PAIN IS WHAT THE PATIENT WAS EXPERIENCING AND REVISED DUE TO. THE POLY WAS REMOVED ALONG WITH THE TIB BASE AND KEEL. A NEW TIB BASE WAS IMPLANTED ALONG WITH A 2.5 MM AUGMENTS AND A POLY. (RIGHT)
Patient problems: Pain
MAUDE report 8759518 ↗
Other Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer devices
- ATTUNE 1512-14-050Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER106 reports
- ATTUNE 1504-40-205Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall53 reports
- ATTUNE 1504-40-105Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall46 reports
- ATTUNE 1547-06-001Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall37 reports
- ATTUNE 1513-12-060Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER72 reports
- Triathlon 5521-B-300Howmedica Osteonics Corp. · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall19 reports
- Triathlon 5531-G-709-EHowmedica Osteonics Corp. · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall19 reports
- ATTUNE 1512-16-080Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.