PROFEMUR® PHA0CLE5Recalls & reported problems
Microport Orthopedics Inc. · PROFEMUR® Z CLASSIC STEM SZ 5 VARUS 8 DG SHORT NECK · Class 2 · Implant
All models of PROFEMUR (116)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI M684PHA0CLE51), received between Feb 6, 2025 and Feb 6, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Loss of Osseointegration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Loss of Osseointegration1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 6, 2025Loss of Osseointegration; Loss of Osseointegration
ALLEGEDLY, PATIENT UNDERWENT THR ON (B)(6) 2018 LEFT HIP REVISED ON (B)(6) 2019 DUE FEMORAL STEM LOOSENING. THE FEMORAL STEM REVISED WAS A PROFEMUR Z CLASSIC SIZE 5 SHORT VARUS NECK AND FEMORAL HEAD WAS A BIOLOX DELTA 28MM L. BOTH COMPONENTS WERE REVISED THERE IS NO FURTHER DATA ON WHAT DEVICES WERE USED. ADDITIONAL HISTORY: THIS IS THE SAME PATIENT AND SAME HIP THAT EXPERIENCED THE ISSUE WHERE THE STEM SAT HIGHER THAN THE BROACH, REF: (B)(4) (SPEC REF: (B)(4).
Patient problems: Insufficient Information
MAUDE report 21324663 ↗
Other Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented devices
- BIOLOX DELTA 1365-32-310Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented551 reports
- PINNACLE ALTRX 1221-36-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented481 reports
- BIOLOX DELTA 1365-32-320Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death314 reports
- BIOLOX DELTA 1365-36-720Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death189 reports
- DJO SURGICAL 400-03-362Encore Medical, L.P. · Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented187 reports
- Anthology 71365705Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented176 reports
- BIOLOX DELTA 1365-40-710Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented170 reports
- PINNACLE GRIPTION 1217-32-054Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented169 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.