PROFEMUR® PRTLEL24Recalls & reported problems
Microport Orthopedics Inc. · PROFEMUR® TL CLASSIC STEM SIZE 4 VARUS 8 DG LONG NECK · Class 2 · Implant
All models of PROFEMUR (116)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI M684PRTLEL241), received between Apr 6, 2022 and Apr 6, 2022 — classified as 1 injury.
The most frequently reported specific device problem is “Loss of Osseointegration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Loss of Osseointegration1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 6, 2022Loss of Osseointegration; Loss of Osseointegration
ALLEGEDLY, AFTER CONFIRMING THE FINAL TRIAL, THE STEM WAS DRIVEN IN, BUT IT FLOATED ABOUT 2 MM, SO IT WAS DRIVEN IN HARD. ALTHOUGH A SUSPICIOUS SHADOW WAS CONFIRMED BY POSTOPERATIVE X-RAY, IT WAS DECIDED TO FOLLOW UP THE PATIENT. THE NEXT DAY, WE SUSPECTED MOBILITY AND CONFIRMED IT WITH X-RAYS AND CT. A FRACTURE WAS FOUND. IN ADDITION, HE DEVELOPED HYPERTENSIVE ENCEPHALOPATHY AND CARDIAC DISEASE, AND HIS DEMENTIA IS DIFFICULT TO CONTROL. IT WAS DETERMINED THAT REOPERATION WAS NOT POSSIBLE. HE IS NOW WEARING A PROTECTIVE HIP BRACE AND WILL BE LOADED IN AT LEAST 8 WEEKS. THE PATIENT DOES NOT COMPLAIN OF PAIN, BUT WE BELIEVE IT IS DUE TO DEMENTIA. (B)(4).
Patient problems: Bone Fracture(s)
MAUDE report 14024553 ↗
FDA clearance and classification
Cleared through 510(k) K140676 on May 30, 2014 (decision: Substantially Equivalent). Submitted by Microport Orthopedics, Inc. as “Profemur Tl Classic Long Neck Hip Stems”. The FDA review took 73 days. FDA record ↗
The FDA regulates product code JDI (prosthesis, hip, semi-constrained, metal/polymer, cemented) under 21 CFR 888.3350 as a Class II device. 21 CFR 888.3350 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the PROFEMUR® PRTLEL24
Has the PROFEMUR® PRTLEL24 been recalled?
No FDA recall record in our data names this exact device identifier (DI M684PRTLEL241), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the PROFEMUR® PRTLEL24?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 6, 2022. That report lists device problem “Loss of Osseointegration” (1); patient problem “Bone Fracture(s)” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the PROFEMUR® PRTLEL24?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the PROFEMUR® PRTLEL24 FDA approved?
It was cleared through 510(k) K140676 on May 30, 2014. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the PROFEMUR® PRTLEL24 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the PROFEMUR® PRTLEL24, and is it still sold?
The FDA's device database lists Microport Orthopedics Inc. as the company responsible for it (brand PROFEMUR®, model PRTLEL24). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented devices
- NA 1365-51-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented752 reports
- NA 1365-50-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented409 reports
- ARTICUL/EZE 1365-21-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented1 recall279 reports
- ARTICUL/EZE 1365-11-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented1 death262 reports
- LFIT 6260-9-236Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, cemented260 reports
- PINNACLE GRIPTION 1217-32-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/polymer, cemented2 deaths237 reports
- ELEOS™ 25002111EOnkos Surgical, Inc. · Prosthesis, hip, semi-constrained, metal/polymer, cemented3 deaths230 reports
- Novation 130-36-52Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented2 recalls125 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page