Skip to content

Ovation iX Iliac Stent Graft Iliac Extension (REF TV-EX121245-J)Recalls & reported problems

Endologix LLC · The TriVascular® Ovation Prime® Abdominal Stent Graft System with the Ovation iX Iliac Stent Graft is an endovascular device delivered via a small diameter catheter to treat abdominal aortic aneurysms (AAAs). The stent graft is designed to reline the diseased vasculature, providing an endovascular blood conduit for isolating the aneurysm from the high pressure flow of blood, thereby reducing the risk of rupture. The stent graft is a modular configuration comprised of an aortic body section, iliac limbs, and iliac extensions as required. The TriVascular Ovation Prime Abdominal Stent Graft System with the Ovation iX Iliac Stent Graft includes, an Aortic Body Stent Graft and delivery catheter, Iliac Limb Stent Grafts and delivery catheters, Iliac Extension Stent Grafts and delivery catheters, as required, a Fill Polymer Kit, and an Autoinjector. · Class 3 · Implant

All models of Ovation iX Iliac Stent Graft (66)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI M701TVEX121245J1), received between Aug 14, 2016 and Aug 14, 2016 — classified as 1 injury.

The most frequently reported specific device problem is “Improper or Incorrect Procedure or Method” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Improper or Incorrect Procedure or Method1
  • Occlusion Within Device1

Patient problems

  • Occlusion1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 14, 2016Occlusion Within Device; Improper or Incorrect Procedure or Method; Occlusion Within Device; Improper or Incorrect Procedure or Method

    AN AFX ABDOMINAL STENT GRAFT SYSTEM WITH AN OVATION IX ILIAC LIMB EXTENSION WAS IMPLANTED TO TREAT AN ABDOMINAL AORTIC ANEURYSM. UPON DEPLOYMENT OF THE ILIAC LIMB EXTENSION, THE ILIAC LIMB EXTENSION WAS INADVERTENTLY DEPLOYED BETWEEN THE STENT GRAFT MAINBODY AND THE AORTIC WALL, OCCLUDING THE BLOOD FLOW TO THE RIGHT COMMON ILIAC ARTERY. THE PATIENT WAS CONVERTED TO AUI WITH A FEM-FEM BYPASS TO RESTORE BLOOD FLOW AND THE ANEURYSM WAS SUCCESSFULLY EXCLUDED. AS OF THE DATE OF THIS REPORT, THERE HAVE BEEN NO ADDITIONAL PATIENT SEQUELAE REPORTED.

    Patient problems: Occlusion

    MAUDE report 5874832 ↗

Other System, Endovascular Graft, Aortic Aneurysm Treatment devices

All System, Endovascular Graft, Aortic Aneurysm Treatment devices →

Sources and updates