Ovation iX Iliac Stent Graft Iliac Limb (REF TV-IL1412100-J)Recalls & reported problems

Endologix LLC · The TriVascular® Ovation Prime® Abdominal Stent Graft System with the Ovation iX Iliac Stent Graft is an endovascular device delivered via a small diameter catheter to treat abdominal aortic aneurysms (AAAs). The stent graft is designed to reline the diseased vasculature, providing an endovascular blood conduit for isolating the aneurysm from the high pressure flow of blood, thereby reducing the risk of rupture. The stent graft is a modular configuration comprised of an aortic body section, iliac limbs, and iliac extensions as required. The TriVascular Ovation Prime Abdominal Stent Graft System with the Ovation iX Iliac Stent Graft includes, an Aortic Body Stent Graft and delivery catheter, Iliac Limb Stent Grafts and delivery catheters, Iliac Extension Stent Grafts and delivery catheters, as required, a Fill Polymer Kit, and an Autoinjector. · Class 3 · Implant

All models of Ovation iX Iliac Stent Graft (66)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI M701TVIL1412100J1), received between Feb 27, 2018 and Aug 28, 2025 — classified as 4 injuries.

The most frequently reported specific device problem is “Complete Blockage” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Complete Blockage1
  • Device Stenosis1
  • Device-Device Incompatibility1
  • Difficult to Advance1
  • Insufficient Device Problem Information1

Patient problems

  • Failure of Implant2
  • Hematoma1
  • No Consequences Or Impact To Patient1
  • Obstruction/Occlusion1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 28, 2025Device Stenosis; Device Stenosis

    THE PATIENT WAS IMPLANTED WITH THE OVATION IX ABDOMINAL STENT GRAFT SYSTEM TO TREAT AN ABDOMINAL AORTIC ANEURYSM (AAA) ON (B)(6) 2018. ON (B)(6) 2019 THE PATIENT DEVELOPED AN OCCLUDED RIGHT LIMB WITH THROMBUS IN THE RIGHT COMMON FEMORAL ARTERY ANEURYSM. THE PHYSICIAN ELECTED TO PERFORM A THROMBECTOMY OF THE RIGHT INTERNAL ILIAC ARTERY AS WELL AS IMPLANT UNKNOWN (NON-ENDOLOGIX) BILATERAL COMMON ILIAC ARTERY STENTS. THEN A RIGHT EXTERNAL ILIAC ARTERY/SUPERFICIAL FEMORAL ARTERY EMBOLECTOMY WAS PERFORMED, AN OPEN THROMBECTOMY OF THE RIGHT CORONARY FEMORAL ARTERY WAS PERFORMED, AND A VIABAHN (NON-ENDOLOGIX) STENT WAS PLACED FROM THE RIGHT SUPERFICIAL FEMORAL ARTERY TO BELOW-KNEE POPLITEAL ARTERY. THE FINAL PATIENT'S STATUS WAS REPORTED AS STABLE.

    Patient problems: Obstruction/Occlusion

    MAUDE report 22913272 ↗
  • InjuryOct 10, 2022Insufficient Device Problem Information; Insufficient Device Problem Information

    THE PATIENT WAS INITIALLY IMPLANTED WITH AN OVATION IX STENT GRAFT SYSTEM TO TREAT AN ABDOMINAL AORTIC ANEURYSM (AAA). IT WAS REPORTED THAT DURING THE INITIAL PROCEDURE THE GRAFT WAS DIFFICULT TO DEMATE, THE IMPLANT WAS DISPLACED AND THERE WAS TYPE 1A ENDOLEAK. THIS EVENT WAS PREVIOUSLY CAPTURED PER PATIENT ID (B)(6). PATIENT WAS NOT IN ROUTINE FOLLOW-UP CARE. APPROXIMATELY SIX (6) YEARS POST IMPLANT THE PHYSICIAN REPORTED THAT THE AAA RUPTURED FROM A TYPE 1 ENDOLEAK. UPON FURTHER REVIEW IT APPEARS THERE WAS A JUXTARENAL ANEURYSM THAT MAY HAVE CAUSED THE RUPTURE AS THERE WAS NO VISIBLE TYPE 1A ENDOLEAK, AND THE ISSUE APPEARS TO BE WHERE THAT PROXIMAL CROWN IS ABOVE THE OVATION IX FABRIC. THE PHYSICIAN ELECTED TO IMPLANT A COOK PMEG (PHYSICIAN MODIFIED ENDOGRAFT) (NON-ENDOLOGIX) STENT TO RESOLVE THIS EVENT. THE PATIENT WAS REPORTED AS DOING WELL POST THIS SECONDARY PROCEDURE ON (B)(6) 2022. THIS EVENT WAS PREVIOUSLY CAPTURED PER PATIENT ID (B)(6). ADDITIONALLY, DURING THE INITIAL IMPLANT PROCEDURE, A LACERATION OCCURRED THAT REQUIRED EMERGENT REPAIR. IN ADDITION, PATIENT RETURNED TO THE HOSPITAL TWELVE (12) DAYS POST INITIAL PROCEDURE FOR BLOOD TRANSFUSION AND LEFT GROIN HEMATOMA EV

    Patient problems: Failure of Implant; Hematoma

    MAUDE report 15570932 ↗
  • InjurySep 20, 2021Complete Blockage; Device-Device Incompatibility; Complete Blockage; Device-Device Incompatibility

    THE PATIENT WAS INITIALLY IMPLANTED WITH AN AFX2 BIFURCATED STENT GRAFT, A VELA SUPRARENAL EXTENSION AND AN OVATION LIMB EXTENSION TO TREAT AN ABDOMINAL AORTIC ANEURYSM (AAA). THIS CASE IS OUTSIDE THE INDICATIONS OF USE (OFF -LABEL) DUE THE USE OF AFX WITH OVATION DEVICES. APPROXIMATELY ONE (1) DAY POST INITIAL PROCEDURE, THE PATIENT PRESENTED WITH THROMBOSIS OF THE RIGHT LIMB CAUSING AN OCCLUSION OF THE STENT GRAFT. THE PHYSICIAN SUCCESSFULLY TREATED THE PATIENT BY IMPLANTING TWO (2) BARE METAL PERIPHERAL STENTS (NON-ENDOLOGIX) AND THE PATIENT IS REPORTEDLY DOING WELL.

    Patient problems: Failure of Implant

    MAUDE report 12502486 ↗
  • InjuryFeb 27, 2018Difficult to Advance; Difficult to Advance

    AN OVATION IX ILIAC LIMB STENT GRAFT SYSTEM WAS IMPLANTED TO TREAT AN ABDOMINAL AORTIC ANEURYSM. DURING THE PROCEDURE, THE IPSILATERAL LIMB WAS UNABLE TO BE ADVANCED, DESPITE TROUBLESHOOTING TECHNIQUES. PHYSICIAN ELECTED TO REMOVE THE DEVICE AND USE A NEW DEVICE. THE LIMB WAS SUCCESSFULLY IMPLANTED AND THE CASE CONCLUDED WITH SUCCESSFUL ANEURYSM EXCLUSION. THERE WAS NO PATIENT SEQUELAE AS RESULT OF THIS EVENT, AND AS OF THE DATE OF THIS REPORT THERE HAVE BEEN NO ADDITIONAL PATIENT SEQUELAE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7299390 ↗

Other System, Endovascular Graft, Aortic Aneurysm Treatment devices