Lumbar Plate System 1Recalls & reported problems
Genesys Orthopedics Systems LLC · Lumbar Plate Helios Driver - Assembly · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI M719GLP1590), received between Feb 28, 2022 and Feb 28, 2022 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
- Fracture1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 28, 2022Break; Fracture; Break; Fracture
DURING A BINARY LUMBAR PLATE PROCEDURE THE TIP OF THE THREADED INNER SHAFT OF THE LUMBAR PLATE DRIVER BROKE OFF (SEPARATED) IN THE HEAD OF A LUMBAR PLATE SCREW. THE REPRESENTATIVE COVERING THE CASE STATED THERE WERE NO ABNORMALITIES DURING INSERTION OF THE SCREW AND NOTHING EXTRAORDINARY OCCURRED PRIOR TO THE INSTRUMENT FAILURE. THE BROKEN PORTION OF THE INSTRUMENT COULD NOT BE RETRIEVED FROM THE SCREW AND WAS SUBSEQUENTLY IMPLANTED IN THE PATIENT.
Patient problems: Foreign Body In Patient
MAUDE report 13620342 ↗
Other Appliance, Fixation, Spinal Intervertebral Body devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- Elegance® Anterior Cervical Plate 53430353Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430108Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430114Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430240Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430236Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.