Skip to content

Photodynamic Bone Stabilization System US2213240Recalls & reported problems

Illuminoss Medical, Inc. · 22/13mmx240mm Photodynamic Bone Stabilization LED Light System · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
1
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI M986US22132400), received between Nov 18, 2025 and Nov 18, 2025 — classified as 1 death.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Embolism/Embolus1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • DeathNov 18, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ILLUMINOSS IMPLANTED IN LEFT HUMERUS, CURED. RIGHT FEMUR RETROGRADE IM NAIL DURING THE CURING PROCESS OF ILLUMINOSS. ILLUMINOSS IMPLANT FULLY CURED AND FEMORAL NAIL WAS INSERTED AND DISTAL CROSS LOCKING SCREWS FOR THE FEMUR NAIL WERE PLACED BY RESIDENT WHILE SURGEON SCORED AND REMOVED THE CATHETER. AFTER SCORING AND REMOVAL OF CATHETER, WHILE RESIDENT WAS PLACING DISTAL CROSS LOCKING SCREWS IN FEMORAL IM NAIL, ANESTHESIA NOTIFIED SURGEON THAT PATIENTS PRESSURES WERE LOW. PT CODED AND WAS REVIVED AND CODED AGAIN AND PASSED. NOTE THAT THE REP NOTIFIED ANESTHESIA PRIOR TO ILLUMINOSS INSERTION THAT SURGEON WAS GOING TO IMPLANT AND TO BE AWARE OF PRESSURIZATION OF CANAL SAYING IT OUT LOUD TO THE OR ROOM, INCLUDING ANESTHESIA AND WAS THANKED FOR THE COMMENT AND ALERT. PATIENT WAS NORMAL DURING IMPLANTATION AND TOTAL CURING OF ILLUMINOSS.

    Patient problems: Embolism/Embolus

    MAUDE report 23584170 ↗

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page