NutraGlide Nasal Feeding TubeRecalls & reported problems across all models
Applied Medical Technology, Inc. · 8 models in the FDA device registry
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls
- 9
We found 8 models of NutraGlide Nasal Feeding Tube by Applied Medical Technology, Inc. in the FDA's device registry (GUDID). Together they are named in 3 adverse event reports in the FDA's MAUDE database, received between Jun 19, 2025 and May 5, 2026 — classified as 2 injuries, 1 malfunction.
9 FDA recall records name at least one of these models by its device identifier.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
NutraGlide Nasal Feeding Tube recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Oct 6, 2025Class IICompleted
The nasal feeding tube may be occluded
Z-0498-2026 · Root cause: Process control · Recall details · FDA record ↗
- Oct 6, 2025Class IICompleted
The nasal feeding tube may be occluded
Z-0497-2026 · Root cause: Process control · Recall details · FDA record ↗
- Oct 6, 2025Class IICompleted
The nasal feeding tube may be occluded
Z-0496-2026 · Root cause: Process control · Recall details · FDA record ↗
- Oct 6, 2025Class IICompleted
The nasal feeding tube may be occluded
Z-0495-2026 · Root cause: Process control · Recall details · FDA record ↗
- Oct 6, 2025Class IICompleted
The nasal feeding tube may be occluded
Z-0494-2026 · Root cause: Process control · Recall details · FDA record ↗
- Aug 12, 2025Class IICompleted
The nasal feeding tubes, NutraGlide, subject to this recall have distal tips that may detach at lower than expected forces.
Z-0130-2026 · Root cause: Process control · Recall details · FDA record ↗
- Aug 12, 2025Class IICompleted
The nasal feeding tubes, NutraGlide, subject to this recall have distal tips that may detach at lower than expected forces.
Z-0129-2026 · Root cause: Process control · Recall details · FDA record ↗
- Aug 12, 2025Class IICompleted
The nasal feeding tubes, NutraGlide, subject to this recall have distal tips that may detach at lower than expected forces.
Z-0128-2026 · Root cause: Process control · Recall details · FDA record ↗
- Aug 12, 2025Class IICompleted
The nasal feeding tubes, NutraGlide, subject to this recall have distal tips that may detach at lower than expected forces.
Z-0127-2026 · Root cause: Process control · Recall details · FDA record ↗
Most reported NutraGlide Nasal Feeding Tube problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- No Apparent Adverse Event1
Patient problems
- Bowel Perforation1
- No Clinical Signs, Symptoms or Conditions1
- Perforation1
NutraGlide Nasal Feeding Tube models
8 models, most reported first. Each model has its own page with its reports, recalls and device details.
- NutraGlide Nasal Feeding Tube ENFT-06055-ITubes, Gastrointestinal (And Accessories)2 recalls0 reports
- NutraGlide Nasal Feeding Tube ENFT-06090-ITubes, Gastrointestinal (And Accessories)2 recalls0 reports
- NutraGlide Nasal Feeding Tube ENFT-05055-ITubes, Gastrointestinal (And Accessories)2 recalls0 reports
- NutraGlide Nasal Feeding Tube ENFT-05090-ITubes, Gastrointestinal (And Accessories)2 recalls0 reports
- NutraGlide Nasal Feeding Tube ENFT-05055-N-ITubes, Gastrointestinal (And Accessories)1 recall0 reports
- NutraGlide Nasal Feeding Tube ENFT-05090-ITubes, Gastrointestinal (And Accessories)1 report
- NutraGlide Nasal Feeding Tube ENFT-08090-ITubes, Gastrointestinal (And Accessories)1 report
- NutraGlide Nasal Feeding Tube ENFT-08110-ITubes, Gastrointestinal (And Accessories)1 report
Recent NutraGlide Nasal Feeding Tube adverse event reports
The 3 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionMay 5, 2026No Apparent Adverse Event
PER THE ORIGINAL REPORTER IN MEDWATCH REPORT #: MW5184947, IT WAS REPORTED THAT THE "GUIDEWIRE PERFORATED DHT DURING PLACEMENT RESULTING IN THE GUIDEWIRE EXTENDING OUT THE SIDE OF THE DHT AND INTO THE STOMACH".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25080316 ↗InjuryMar 24, 2026Adverse Event Without Identified Device or Use Problem
PER INFORMATION REPORTED BY THE USER FACILITY TO AMT SALES REPRESENTATIVES, A GASTRIC PERFORATION OCCURRED ROUGHLY A MONTH AFTER THE PLACEMENT OF A NFT-08090-I. THE PERFORATION REPORTEDLY OCCURRED IN AN 11-MONTH-OLD 11KG BABY WITH LEUKEMIA. PER THE HOSPITAL'S POLICY, THIS SIZE NUTRAGLIDE WAS TOO LARGE FOR THE PATIENT, AND THEY SHOULD HAVE PLACED A 6-8F NUTRAGLIDE. IT WAS ALSO REPORTED THAT THE PATIENT HAD AN INTERNAL SAFETY REPORT THE WEEK BEFORE THE INCIDENT OCCURRED. THE HOSPITAL STAFF REPORTEDLY DID NOT KNOW HOW FAR THE TUBE WAS INSERTED AND IF IT WAS IN THE CORRECT SPOT. A PH CHECK WAS PERFORMED TO CHECK PLACEMENT. DURING THIS CHECK THE STAFF NOTED THE TUBE WAS TOO LARGE FOR THE PATIENT PER THEIR POLICY. IT WAS REPORTED THEY DECIDED TO LEAVE THE TUBE IN PLACE. DUE TO THE PERFORATION THE PATIENT WAS TAKEN TO THE OPERATING ROOM FOR URGENT REPAIR. IT WAS REPORTED TO AMT THAT THE PATIENT WAS RECOVERING FROM THE EVENT.
Patient problems: Perforation
MAUDE report 24673211 ↗InjuryJun 19, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PER THE ORIGINAL REPORTER IN UF #: (B)(4), IT WAS REPORTED THAT A,"5 FRENCH 90CM NUTRAGLIDE NJT [NASOJEJUNAL TUBE] PLACED ON [REDACTED] FOR NUTRITION. THE PLACEMENT OF THIS TUBE WAS CONFIRMED BY X-RAY AND INSERTION WAS DONE PER HOSPITAL POLICY. ON [REDACTED], ABOUT THREE DAYS LATER, ABDOMINAL ULTRASOUND IDENTIFIED FREE FLUID NOTED IN ABDOMEN, GIVEN HCT [HEMATOCRIT] DROP, CONCERN FOR HEMOPERITONEUM. PATIENT TRANSFERRED EMERGENTLY TO ICU [INTENSIVE CARE UNIT], INTUBATED AND GEN SURGERY EXPLORATORY LAP IDENTIFIED FEEDS PRESENT IN INTRA-ABDOMINAL SPACE AND NJT FOUND TO HAVE GONE THROUGH INTESTINAL WALL ABOUT 1 CM AT THE D2-D3 JUNCTION RIGHT AS THE DUODENUM MAKES ITS TURN. INTESTINES ALL LOOKED HEALTHY, AND NO BOWEL HAD TO BE RESECTED. HOLE WAS SEWN SHUT AND ABDOMEN CLOSED".
Patient problems: Bowel Perforation
MAUDE report 22293496 ↗
Other Applied Medical Technology, Inc. products
All Applied Medical Technology, Inc. devices →Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page