WATCHMAN TruSeal Access SystemRecalls & reported problems across all models

Boston Scientific Corporation · 3 models in the FDA device registry

Data updated Oct 16, 2026 from official FDA records · Editorial policy

3 open recalls name at least one WATCHMAN TruSeal Access System model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.

Adverse event reports
288
Deaths reported
12
Injuries reported
222
Recalls
3

We found 3 models of WATCHMAN TruSeal Access System by Boston Scientific Corporation in the FDA's device registry (GUDID). Together they are named in 288 adverse event reports in the FDA's MAUDE database, received between Nov 29, 2018 and Aug 21, 2025 — classified as 12 deaths, 222 injuries, 54 malfunctions.

The most frequently reported specific device problem is “Material Deformation” (27 reports).

3 FDA recall records name at least one of these models by its device identifier, 3 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works

Reports received per month, all models

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 4 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

WATCHMAN TruSeal Access System recalls

FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.

  1. Jul 29, 2025Open, Classified

    Boston Scientific has identified a higher likelihood of air embolism events when procedures are performed without positive pressure-controlled ventilation. According to published literature and clinical data, in percutaneous procedures requiring transseptal access to the left atrium when conscious or deep sedation is used, patients have an approximately three-times higher risk (U.S. study) of negative left atrium pressure and air ingress. This risk is especially prevalent in patients with pre-existing low left atrial pressure, hypovolemia, and partial upper airway collapse.

    Z-2433-2025 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

  2. Jul 29, 2025Open, Classified

    Boston Scientific has identified a higher likelihood of air embolism events when procedures are performed without positive pressure-controlled ventilation. According to published literature and clinical data, in percutaneous procedures requiring transseptal access to the left atrium when conscious or deep sedation is used, patients have an approximately three-times higher risk (U.S. study) of negative left atrium pressure and air ingress. This risk is especially prevalent in patients with pre-existing low left atrial pressure, hypovolemia, and partial upper airway collapse.

    Z-2432-2025 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

  3. Jul 29, 2025Open, Classified

    Boston Scientific has identified a higher likelihood of air embolism events when procedures are performed without positive pressure-controlled ventilation. According to published literature and clinical data, in percutaneous procedures requiring transseptal access to the left atrium when conscious or deep sedation is used, patients have an approximately three-times higher risk (U.S. study) of negative left atrium pressure and air ingress. This risk is especially prevalent in patients with pre-existing low left atrial pressure, hypovolemia, and partial upper airway collapse.

    Z-2431-2025 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported WATCHMAN TruSeal Access System problems

Device problems

  • Adverse Event Without Identified Device or Use Problem221
  • Material Deformation27
  • Material Integrity Problem20
  • Difficult to Remove10
  • Gas/Air Leak6
  • Leak/Splash5
  • Device-Device Incompatibility4
  • Detachment of Device or Device Component3

Patient problems

  • Pericardial Effusion74
  • Thrombosis/Thrombus50
  • Cardiac Perforation35
  • Hematoma31
  • Low Blood Pressure/ Hypotension30
  • No Consequences Or Impact To Patient30
  • No Clinical Signs, Symptoms or Conditions27
  • Air Embolism20

WATCHMAN TruSeal Access System models

3 models, most reported first. Each model has its own page with its reports, recalls and device details.

Recent WATCHMAN TruSeal Access System adverse event reports

The 15 most recent reports across all models, in the reporter's own words as published by the FDA.

Other Boston Scientific Corporation products

All Boston Scientific Corporation devices →

Sources and updates