Hybrid Glenoid recallZ-2216-2017 · Zimmer Biomet, Inc. · initiated Apr 26, 2017
Terminated
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Zimmer Biomet, Inc. or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Zimmer Biomet is conducting a voluntary recall for a single lot of the Modular Hybrid Glenoid Base Large for the Comprehensive Shoulder System after it was determined that two pieces from the lot were moved to finished goods and shipped despite having an open Non-Conformance Report (NCR). The NCR indicated that one piece from the lot had scratches and the other non-confirming threads.
FDA root cause category: Under Investigation by firm
What the company is doing
Zimmer Biomet initiated a voluntary recall on April 26, 2017, for a single lot of the Modular Hybrid Glenoid Base Large for the Comprehensive Shoulder System after it was determined that two pieces from the lot were moved to finished goods and shipped despite having an open Non-Conformance Report (NCR). The NCR indicated that one piece from the lot had scratches and the other non-conforming threads. Notices were distributed via FedEx to customers. Risk Managers were instructed as follows: 1. Review the notification and ensure affected personnel are aware of the contents. 2. Assist your Zimmer Biomet sales representative quarantine all affected product. 3. Your Zimmer Biomet sales representative will remove the affected product from your facility. 4. Complete Attachment 1 Certificate of Acknowledgement. a. Return a digital copy within three (3) to [email protected]. b. Retain a copy of the Acknowledgement Form with your field action records in the event of a compliance audit of your facilities documentation. 5. If after reviewing this notice you have further questions or concerns please call 411 Technical Services at 574- 371-3071 between 8:00 am and 5:00pm EST, Monday through Friday. Calls received outside of the call center operating hours will receive a prompt to record a voicemail or be transferred to an on-call representative in the case of an emergency. Alternatively, your questions may be sent by email to [email protected]. Surgeons were instructed as follows: Review the notification for awareness of the contents. 2. There are no specific patient monitoring instructions related to this field action that are recommended beyond your existing follow up schedule. 3. Complete Attachment 1 Certificate of Acknowledgement. a. Return a digital copy to [email protected]. b. Retain a copy of the Acknowledgement Form with your field action records in the event of a co
Recall details
- Recall number
- Z-2216-2017
- Status
- Terminated
- Initiated by the company
- Apr 26, 2017
- Recalling firm
- Zimmer Biomet, Inc.
- Quantity
- 16
- Product code
- KWS
- FDA submissions
- K060694
- Distribution
- Worldwide Distribution - US including OH AZ ID PA AR MN IL CA MD CA MN NY Foreign: Canada
Product description
Modular Hybrid Glenoid Base Large for the Comprehensive Shoulder System, The product is placed into an AlOx coated PET pouch and vacuum sealed with an Argon flush. The vacuum sealed product is then placed into a Tyvek/film pouch and that pouch is heat sealed. The fully pouched product is then labeled and placed into a carton with an IFU. The carton is then labeled and shrink wrapped. The labels also include a sterilization indication dot. This system is intended for primary and revision total shoulder arthroplasty, as well as hemi-arthroplasty
Code information (models, lots, serial numbers)
Model Number: 113956, Modular Hybrid Glenoid Base Large, Item Number: 113956, Lot Number: 270260, UDI Number: (01) 00880304462618 (17) 211204 (10) 270260
Devices named in this recall
1 device in the FDA device registry whose identifier appears in the recall's code information.
- Hybrid Glenoid 113956Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, NON-CONSTRAINED, METAL/POLYMER CEMENTED1 recall2 reports
Product lines
Other devices under the same FDA submission
5 devices cleared under K060694 are not named by identifier in this recall. One submission often covers many models, so they may or may not be affected.
- Comprehensive Modular Hybrid Glenoid SSI002231Biomet Orthopedics, LLC · Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented1 recall0 reports
- Hybrid Glenoid PT-113950Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED22 reports
- COMPREHENSIVE SHOULDER SYSTEM 110004319Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED1 report
- Comprehensive® Instruments 110003484Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED1 report
- Comprehensive® Shoulder System 110004319Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED1 report
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 16, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page