Discovery IGS 730 Interventional Fluoroscopic X-ray Systems recallZ-2386-2018 · GE Medical Systems, SCS · initiated Mar 29, 2018

Class II Terminated All recalls posted in October 2018

Is my device affected?

  1. Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
  2. If yours is listed, follow the instructions from GE Medical Systems, SCS or your healthcare provider. The company's action is summarized under what the company is doing.
  3. Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.

Where to find your model and lot numbers · What recall classes and statuses mean

Why it was recalled

The Discovery IGS and Innova IGS systems may experience X-ray abort errors which could result in the loss of imaging mode before or during fluoroscopic use.

FDA root cause category: Process control

What the company is doing

GE Healthcare notified customers on approximately 03/29/2018, via an URGENT MEDICAL DEVICE CORRECTION letter. Safety instructions included that before each use, to ensure the IGS system is fully functional as indicated in the GE product labeling and follow each facility's established procedures before and during each use to manage the patient if a repeated X-ray abort error occurs during the procedure or in the case a complete loss of fluoroscopic viewing capability may occur. If the problem persists, customers are instructed to contact their local GE Healthcare Service Representative. Additionally, customers are instructed that GE Healthcare will correct all affected products at no cost and a GE Healthcare representative will contact each customer to arrange for the correction. Questions or concerns regarding the notification can be directed to GE Healthcare Service at 1-800-437-1171 or the local Service Representative.

Recall details

Recall number
Z-2386-2018
Recall class
Class II
Status
Terminated
Initiated by the company
Mar 29, 2018
Posted by the FDA
Oct 5, 2018
Recalling firm
GE Medical Systems, SCS
Quantity
102 devices total
Product code
OWB
FDA submissions
K113403, K122457
Distribution
US distribution: AR, CA, CA, FL, GA, IA, IL, NC, NH, NJ, NM, NY, PA, SC, TN, A,WI, WV. International Distribution: Argentina, Brazil, China, Colombia, Egypt, France, India, Indonesia, Iran, Italy, Japan, Kuwait, Lithuania, Myanmar, Palestine, Poland, Russia, Saudi Arabia, Singapore, Spain, Tunisia, Turkey, United Kingdom, Vietnam.

Product description

Discovery IGS 730 Interventional Fluoroscopic X-ray Systems

Code information (models, lots, serial numbers)

Model Number 5730890, Serial Numbers (System ID): 00000D3-17-030 (904BHHCHY), 00000D3-17-032 (083172440628), 661327IGS730 (00000D3-18-001), GON4598369 (00000D3-18-004), 082416140028 (00000D3-17-025), M4234253 (00000D3-17-028), YV3601 (00000D3-18-005), 6073XR0058 (00000D3-17-031).

Other devices under the same FDA submission

1 device cleared under K113403, K122457 — the recall does not name any of them by identifier. One submission often covers many models, so they may or may not be affected.

Other products in the same recall event

The FDA groups related products into one recall event (event 80177).