STATCLAVE G4 Chamber Autoclave -Tabletop steam sterilizer… recallZ-2285-2023 · Scican Ltd. · initiated Jun 22, 2023
Open, Classified
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Scican Ltd. or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
The STATCLAVE G4 is a dynamic air removal (prevacuum) tabletop steam sterilizer intended for use by a health care provider to sterilize medical products by means of pressurized steam. It is suitable for the sterilization of dental and medical instruments that are validated to be sterilized by steam. The STATCLAVE G4 has not been designed to sterilize liquid loads, bio medical waste or materials not compatible with steam sterilization. The processing of such loads may result in incomplete sterilization and / or damage to the autoclave.
FDA root cause category: Employee error
What the company is doing
SciCan Ltd issued Urgent Medical Device Recall Letter to Distributors on June 22, 2023. via email. Letter states reason for recall, health risk and action to take: " Please immediately reach out to any customers (end users of the autoclave) who have received an affected unit and inform them that they must stop using their unit until it has been checked and, if needed, the gaskets have been installed (please see the last page of this notification for a list of serial numbers affected that were delivered to your organization). From the information received from you, requested in the next step below, our sales representatives will be visiting the location of any affected unit to confirm if the gaskets are missing. " Please immediately complete the MEDICAL DEVICE RECALL RETURN RESPONSE, Acknowledgement and Receipt Form included as the last page of this notice. After all information has been completed, sign and return the form to Israa Howlader, copy Stacey Graf, Rich Strader and Teresa Boyce (their contact information is included on the form). " Please also indicate on the attached Acknowledgement and Receipt form that you have received and understood this correction notice. If you have further questions about the product or the recall, please immediately contact Teresa Boyce [email protected], Stacey Graf at [email protected] or Rich Strader [email protected]. " Once we receive your completed Acknowledgement and Receipt form, we will arrange for one of our sales representatives to visit your customer (the end user) or warehouse where the unit is located to confirm if the gaskets are missing from their unit(s). If the gaskets are missing, in order to apply the correction as soon as possible, our sales representatives will immediately provide the gaskets needed so your trained service technician can install them onto the unit. Please see the attached instructions for directions on how to install the gaskets. (For units that are still in your inve
Recall details
- Recall number
- Z-2285-2023
- Status
- Open, Classified
- Initiated by the company
- Jun 22, 2023
- Posted by the FDA
- Aug 3, 2023
- Recalling firm
- Scican Ltd.
- Quantity
- 19 units
- Product code
- FLE
- FDA submissions
- K190062
- Distribution
- US Nationwide Distribution and in the country of Canada
Product description
STATCLAVE G4 Chamber Autoclave -Tabletop steam sterilizer intended for use by a health care provider to sterilize medical products by means of pressurized steam. Model: G4 621103
Code information (models, lots, serial numbers)
UDI-DI: (01)07540196001786 Serial Numbers: 710423E00039 710423E00034 710423E00038 710423E00052 710423E00033 710423E00005 710423E00013 710423E00036 710423E00006 710423E00007 710423E00037 710423E00059 710423E00035 710423E00055 710423E00042 710423E00050 710423E00045 710423E00043 710423E00040
Devices named in this recall
1 device in the FDA device registry whose identifier appears in the recall's code information.
- STATCLAVE G4 Chamber Autoclave G4-621103Scican Ltd · Sterilizer, Steam1 recall0 reports
Other products in the same recall event
The FDA groups related products into one recall event (event 92682).
- Z-2286-2023 · Open, ClassifiedSTATCLAVE G4 Chamber Autoclave -Tabletop steam sterilizer intended for use by a health care provider to sterilize medical products by means of pressurized steam. Model: G4 62230…
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 16, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page