PremierPro recallZ-2320-2024 · Svs LLC · initiated May 13, 2024
Open, Classified
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Svs LLC or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Firm received complaints regarding skin irritation when using the gloves, disintegration of the gloves when used with certain cleaning solutions, and mislabeled products (e.g., outer box indicating one size, but inner box indicating another size).
FDA root cause category: Under Investigation by firm
What the company is doing
Consignees were notified via email on 05/13/2024. The consignees are instructed to discontinue using PremierPro PlusTM D506X series exam gloves; Notify end-users of this voluntary recall notification and discontinue use of the products within your healthcare facilities; Remove these products from areas where they may be available including all points of care, supply part locations, and central supply warehouses; Return the products within Table A above to the firm at the firm's expense. All returns of the above-listed products will be replaced by S2S Global with internationally-sourced PremierProTM 506x gloves unless the consignee indicates a different preference; Continue reporting any and all issues that may arise with the use of domestically-sourced PremierPro PlusTM D506X series exam gloves to S2S Global; and " Return the completed Medical Device Recall Return Response Acknowledgement and Receipt Form located in Appendix A below to S2S Global.
Recall details
- Recall number
- Z-2320-2024
- Status
- Open, Classified
- Initiated by the company
- May 13, 2024
- Posted by the FDA
- Jul 9, 2024
- Recalling firm
- Svs LLC
- Quantity
- 155,540 inner boxes
- Product code
- LZC
- FDA submissions
- K220825
- Distribution
- US Nationwide distribution in the states of MI, NE, FL, GA, PA, AR, CO, and NY.
Product description
Non-sterile, single use, disposable gloves intended for medical purposes to be worn on the hands of examiners to prevent contamination between a patient and an examiner. The gloves are nitrile, powder-free, ambidextrous, and blue-colored with a beaded cuff. The range of sizes includes small, medium, large, and extra-large.
Code information (models, lots, serial numbers)
Show the full code information (1k characters)
Item Numbers: size XS - D5061/lot number: AEAM1105/UDI: 00811220035433; size S - D5062/lot number: AEAM1103,AEAM1104,AEAM1105,AEAM1106,AEAN0204,AEAN0205,AEAN0206,AEAN0307,AEAN0308,AEAN0309,AEAN0310,AEAN0311,AEAN0312,AEAN0316,AEAN0317,AEAN0318/ UDI: 00811220035440; size M - D5063/lot number: AEAM1104,AEAM1105,AEAM1112,AEAN0204,AEAN0205,AEAN0206,AEAN0307,AEAN0308,AEAN0309,AEAN0311,AEAN0312,AEAN0316,AEAN0317,AEAN0318,AEAN0319,AEAN0320,AEAN0206/UDI: 00811220035457; size L - D5064/lot number: AEAM1103,AEAM1104,AEAM1106,AEAN0204,AEAN0205,AEAN0206,AEAN0307,AEAN0308,AEAN0309,AEAN0310,AEAN0311,AEAN0312,AEAN0317,AEAN0318,AEAN0319,AEAN0320/UDI: 00811220035464; and size XL D5065/lot number: AEAN0204,AEAN0205,AEAN0206,AEAN0308,AEAN0310,AEAN0311/UDI: 00811220035471
Devices named in this recall
5 devices in the FDA device registry whose identifier appears in the recall's code information.
- PremierPro D5061Prestige Ameritech, Ltd. · Patient Examination Glove, Specialty1 recall0 reports
- PremierPro D5062Prestige Ameritech, Ltd. · Patient Examination Glove, Specialty1 recall0 reports
- PremierPro D5063Prestige Ameritech, Ltd. · Patient Examination Glove, Specialty1 recall0 reports
- PremierPro D5064Prestige Ameritech, Ltd. · Patient Examination Glove, Specialty1 recall0 reports
- PremierPro D5065Prestige Ameritech, Ltd. · Patient Examination Glove, Specialty1 recall0 reports
Product lines
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 16, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page