Why it was recalled

Temporary deactivation of collision detection for Forte Robotic Patient Positioning System occasionally experiences issues

FDA root cause category: Process design

What the company is doing

IBA isued Urgent Medical Device Correction letter on July 10, 2024. Letter states reason for recall, health risk and action to take: IBA would like to remind you as IBA Proton Therapy System -PROTEUS 235 user of the warnings present in your Clinical User's Guide which emphasize the importance of carefully monitoring the patients behavior during the different treatment phases. IBA would like to also remind you that the manual hand crank could be used by the system operator for the emergency release of the Patient Positioning System in the situations listed in the Clinical User's Guide and Accelerator Operator's Guide and by following the instructions described in both guides. To be signed and given back to IBA representative on site. PTS-8, PTS-10 and PTS-11 versions: Software upgrade IBA will update the software of the Positioning Management System in order that, after a collision, the request to temporarily disable the collision detection will be sent until the status of the collision detection is well disabled. This solution will be deployed at your site by March 2026. PTS-12 versions: users training and labeling change IBA will provide customer training on the system behavior in PTS-12 versions following collision detections. Additionally, IBA will update the labeling to clarify that users can also move the snout or gantry to go out collision situations. These solutions will be deployed at your site by January 2025

Recall details

Recall number
Z-2693-2024
Status
Open, Classified
Initiated by the company
Jul 10, 2024
Posted by the FDA
Aug 21, 2024
Recalling firm
Ion Beam Applications S.A.
Quantity
19 units
Product code
LHN
FDA submissions
K163500
Distribution
IL,LA, NJ, MI,OK, TN, TX, VA, WA Foreign: Czech Republic France Germany Italy Japan Poland Russia Sweden

Product description

IBA Proton Therapy System - PROTEUS 235- Designed to produce and deliver a proton beam for the treatment of patients with localized tumors and other conditions susceptible to treatment by radiation

Code information (models, lots, serial numbers)

UDI-DI: (01)05404013801138 Serial Numbers; PAT.108 (US), PAT.110 (US), PAT.111 (FR), PAT.112 (US), PAT.113 (US), PAT.114 (CZ), PAT.115 (IT), SAT.116 (US), SAT.117 (PL), SAT.118 (RU), SAT.119 (US), SAT.120 (DE), SAT.122 (SE), SAT.123 (US), SAT.126 (US), SBF.101 (FR), SBF.103 (JP), SBF.104 (JP), SBF.105(US).

Devices named in this recall

1 device in the FDA device registry whose identifier appears in the recall's code information.