Medline Heart Cabg Cds, Ref Cds983376r recallZ-0119-2025 · MEDLINE INDUSTRIES, LP - Northfield · initiated Aug 28, 2024
Open, Classified
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from MEDLINE INDUSTRIES, LP - Northfield or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Medline Industries, LP. has identified certain kits containing the recalled Medtronic lots of the DLP Vessel Cannulae. During manufacturing of the three listed lot numbers, product for model 30001 was incorrectly labeled as model 30000.
FDA root cause category: Under Investigation by firm
What the company is doing
Medline issued an UREGENT MEDICAL DEVICE NOTIFICATION to its consignees on 08/28/2024 via USPS first class mail and email. The notice explained the issue, potential risk, and requested the consignee quarantine the product and response to obtain labeling to be placed on the affected inventory. Distributors are directed to notify those to whom they shipped the affected product.
Recall details
- Recall number
- Z-0119-2025
- Status
- Open, Classified
- Initiated by the company
- Aug 28, 2024
- Posted by the FDA
- Oct 17, 2024
- Recalling firm
- MEDLINE INDUSTRIES, LP - Northfield
- Quantity
- 15 kits
- Product code
- LRO
- FDA submissions
- K213481
- Distribution
- US Nationwide distribution.
Product description
MEDLINE HEART CABG CDS, REF CDS983376R
Code information (models, lots, serial numbers)
UDI/DI 40195327548545 (case), 10195327548544 (each), Lot Numbers: 24BMF012, 24CMG491
Devices named in this recall
1 device in the FDA device registry whose identifier appears in the recall's code information.
- Medline Industries, Inc. CDS983376RMedline Industries, Inc. · General surgery tray2 recalls0 reports
Other devices under the same FDA submission
321 devices cleared under K213481 are not named by identifier in this recall. One submission often covers many models, so they may or may not be affected.
- Centurion ART690Centurion Medical Products Corporation · General Surgery Tray4 recalls0 reports
- Centurion CVI4505Centurion Medical Products Corporation · General Surgery Tray3 recalls0 reports
- MEDLINE ECVC6355Medline Industries, Inc. · General surgery tray3 recalls0 reports
- MEDLINE ECVC1045Medline Industries, Inc. · General surgery tray3 recalls0 reports
- Centurion ART255Centurion Medical Products Corporation · General surgery tray3 recalls0 reports
- Centurion CVI3880Centurion Medical Products Corporation · General surgery tray3 recalls0 reports
- MEDLINE ECVC1375Medline Industries, Inc. · General surgery tray3 recalls0 reports
- MEDLINE DYNDV2520Medline Industries, Inc. · General surgery tray3 recalls0 reports
- Centurion ST11670ACenturion Medical Products Corporation2 recalls0 reports
- Medline Industries, Inc. ECVC6370Centurion Medical Products Corporation · General Surgery Tray2 recalls0 reports
- MEDLINE ECVC6840Medline Industries, Inc. · General surgery tray2 recalls0 reports
- MEDLINE ECVC6265Medline Industries, Inc. · General Surgery Tray2 recalls0 reports
Other products in the same recall event
The FDA groups related products into one recall event (event 95393).
- Z-0120-2025 · Open, ClassifiedMEDLINE HEART OVERHEAD TABLE PACK, REF DYNJ0778508J
- Z-0121-2025 · Open, ClassifiedMEDLINE OPEN HEART PACK, REF DYNJ66216C
- Z-0122-2025 · Open, ClassifiedMEDLINE OPEN HEART, REF DYNJ904261B
- Z-0123-2025 · Open, ClassifiedMEDLINE KIT CV I II, REF DYNJ906071B
- Z-0124-2025 · Open, ClassifiedMEDLINE OPEN HEART NIMC KIT, REF DYNJ908840
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 16, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page