Model Number 40KWFXPLUS.002, Mobile X-ray system recallZ-0247-2026 · Sedecal SA · initiated Jun 10, 2025
Class II Open, Classified All recalls posted in October 2025
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Sedecal SA or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Sedecal sent an email to its consignees to remind the users that the equipment is not water-resistant and must be cleaned strictly according to the instructions in the manual, clearly outlining the possible consequences of improper cleaning.
FDA root cause category: Device Design
What the company is doing
Sedecal emailed their distributors on 06/10/2025 to remind them the users that the equipment is not water-resistant and must be cleaned strictly according to the instructions in the manual, clearly outlining the possible consequences of improper cleaning. on 09/19/2025 the firm issued an Important Safety Notice to its direct consignees via email. This notice initiates Phase 2 of the recall strategy expanding the scope and providing information on stickers to cover gaps around the fine positioning control buttons and a DMC software update that stops unit movement if triggered by a short cicuit or prolonged button press with instructions. Consignees will be contacted by a Sedecal Customer support Service to coordinate the shipment of the necessary conversion kits (quantity and delivery address) to allow upgrading the affected units.
Recall details
- Recall number
- Z-0247-2026
- Recall class
- Class II
- Status
- Open, Classified
- Initiated by the company
- Jun 10, 2025
- Posted by the FDA
- Oct 23, 2025
- Recalling firm
- Sedecal SA
- Quantity
- 8 units
- Product code
- IZL
- FDA submissions
- K161345
- Distribution
- US: CA, IL, and NJ
Product description
Model Number 40KWFXPLUS.002, Mobile X-ray system
Code information (models, lots, serial numbers)
UDI/DI 08436046002166, Serial Numbers: G73508, G73512, G71323, G72419, G78910, G72425, G83214, G70934.
Devices named in this recall
1 device in the FDA device registry whose identifier appears in the recall's code information.
- SEDECAL SM-40HF-B-D-VIRSedecal · Solid State X-Ray Imager (Flat Panel/Digital Imager)12 recalls1 report
Other products in the same recall event
The FDA groups related products into one recall event (event 97075).
- Z-0242-2026 · Open, ClassifiedSedecal Mobile Digital Diagnostic X-Ray Systems; SM-40HF-B-D-KM (AeroDR X30)
- Z-0243-2026 · Open, ClassifiedMobileDiagnost wDR 2.2; Model Number REF 9890-010-89522, Mobile X-ray system
- Z-0244-2026 · Open, ClassifiedModel Number 40KWFX, Mobile X-ray system
- Z-0245-2026 · Open, ClassifiedModel Number 40KW-FX.899, Mobile X-ray system
- Z-0246-2026 · Open, ClassifiedModel Number 40KWFXPLUS, Mobile X-ray system
- Z-0249-2026 · Open, ClassifiedModel Number 40KWFXPLUS.005, Mobile X-ray system
- Z-0250-2026 · Open, ClassifiedModel Number 40KWFXPLUS.889, Mobile X-ray system
- Z-0251-2026 · Open, ClassifiedModel Number 40KWFXPLUS-710CW, Mobile X-ray system
- Z-0252-2026 · Open, ClassifiedModel Number 40KWFXPLUS-710CW.007, Mobile X-ray system
- Z-0253-2026 · Open, ClassifiedModel Number 40KWMOBILE3.899, Mobile X-ray system
- Z-0254-2026 · Open, ClassifiedModel Number SM-20HF-Batt; 20KW ANALOG, Mobile X-ray system
- Z-0255-2026 · Open, ClassifiedModel Number SM-32HF-B-D-C; 32KW 50G, Mobile X-ray system
- Z-0256-2026 · Open, ClassifiedModel SM-32HF-Batt; 32KW ANALOG, Mobile X-ray system
- Z-0257-2026 · Open, ClassifiedModel SM-40HF-B-D-C; 40KW - CANON READY, Mobile X-ray system
- Z-0258-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 50G, Mobile X-ray system
- Z-0259-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 55C, Mobile X-ray system
- Z-0260-2026 · Open, ClassifiedModel SM-40HF-B-D-C; 40KW 70C, Mobile X-ray system
- Z-0261-2026 · Open, ClassifiedModel Number SM-40HF-Batt; 40KW ANALOG, Mobile X-ray system
- Z-0262-2026 · Open, ClassifiedSedecal Easy Moving Plus Model Number SM-50HF-B-D-C; 50KW 50G, Mobile X-ray system
- Z-0263-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 50C, Mobile X-ray system
- Z-0264-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 50G, Mobile X-ray system
- Z-0265-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 55C, Mobile X-ray system
- Z-0266-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 55C/60C, Mobile X-ray system
- Z-0267-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 55G, Mobile X-ray system
- Z-0268-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 55G/60G, Mobile X-ray system
- Z-0269-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 55C, Mobile X-ray system
- Z-0270-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 55C/60C, Mobile X-ray system
- Z-0271-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 70C, Mobile X-ray system
- Z-0272-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 70C EN, Mobile X-ray system
- Z-0273-2026 · Open, ClassifiedModel Number SM-40HF-B-D-C; 40KW 70C READY, Mobile X-ray system
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 18, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page