Skip to content

Medline and Centurion medical convenience kits, containing… recallZ-2041-2026 · Medline Industries, LP · initiated Mar 16, 2026

Open, Classified

Is my device affected?

  1. Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
  2. If yours is listed, follow the instructions from Medline Industries, LP or your healthcare provider. The company's action is summarized under what the company is doing.
  3. Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.

Where to find your model and lot numbers · What recall classes and statuses mean

Why it was recalled

Medline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Cardinal Health Webcol Large Alcohol Prep Pads. Cardinal Health has deemed Webcol Large Alcohol Prep Pads to be non-sterile following the discovery of a contaminant (Paenibacillus phoenicis) during a routine sterilization dose audit.

FDA root cause category: Under Investigation by firm

What the company is doing

Medline Industries, LP issued an URGENT MEDICAL DEVICE RECALL notice to its consignees on 3/16/2026 via USPS first class mail and email. The notice explained the issue, potential risk, and requested the affected product be quarantined pending additional labeling. Consignees were directed to respond to the notice via Website link: https://recalls.medline.com, and upon receipt of the submitted response form, the account will receive over-labels to place on affected inventory, with instructions for the user to remove and discard the affected component prior to using the kit. These labels will be provided via FedEx overnight. Distributors or those who have further distributed the product are directed to notify those receiving the affected kits, and to include the customers quantities on the response form. Upon receipt of your submitted response form, you will receive over-labels to provide to the customers to affix to their affected product. For questions, contact the Recall Department at 866-359-1704 or [email protected].

Recall details

Recall number
Z-2041-2026
Status
Open, Classified
Initiated by the company
Mar 16, 2026
Posted by the FDA
Apr 30, 2026
Recalling firm
Medline Industries, LP
Quantity
40845 kits
Product code
LRO
FDA submissions
K213481
Distribution
US Nationwide distribution.

Product description

Medline and Centurion medical convenience kits, containing Webcol Large Alcohol Prep Pads, labeled as: 1. FOLEY CARE KIT, Medline Kit SKU UROT1044; 2. IV START KIT WITH EXTENSION TUBING, Medline Kit SKU IV8770; 3. IV START KIT, Medline Kit SKU DYNDV2520; 4. ARTERIAL LINE BUNDLE, Medline Kit SKU ART255; 5. ON/OFF TRAY, Medline Kit SKU DYNDC2969; 6. IV START KIT, Medline Kit SKU DYNDV2520; 7. IV START KIT WITH EXTENSION TUBING, Medline Kit SKU IV8770; 8. (Centurion) ARTERIAL LINE BUNDLE, Medline Kit SKU ART255; 9. ON/OFF TRAY, Medline Kit SKU DYNDC2969; 10. CVAD DRESSING CHANGE KIT, Medline Kit SKU EBSI1364A.

Code information (models, lots, serial numbers)

Show the full code information (1k characters)

Medline Kit SKU UROT1044: UDI/DI each 10889942873890, UDI/DI case 40889942873891, Lot Number: 26BBC230; Medline Kit SKU IV8770: UDI/DI each 10653160382638, UDI/DI case 00653160382631, Lot Number: 2025101090; Medline Kit SKU DYNDV2520: UDI/DI each 10653160384045, UDI/DI case 00653160384048, Lot Number: 2025112090; Medline Kit SKU ART255: UDI/DI each 10653160367598, UDI/DI case 00653160367591, Lot Number: 2025111890; Medline Kit SKU DYNDC2969: UDI/DI each 10653160376071, UDI/DI case 00653160376074, Lot Number: 2025120190; Medline Kit SKU DYNDV2520: UDI/DI each 10653160384045, UDI/DI case 00653160384048, Lot Number: 2026010290; Medline Kit SKU IV8770: UDI/DI each 10653160382638, UDI/DI case 00653160382631, Lot Number: 2026010790; Medline Kit SKU ART255: UDI/DI each 10653160367598, UDI/DI case 00653160367591, Lot Number: 2026012090; Medline Kit SKU DYNDC2969: UDI/DI each 10653160376071, UDI/DI case 00653160376074, Lot Number: 2026012390; Medline Kit SKU EBSI1364A: UDI/DI each 10653160363163, UDI/DI case 00653160363166, Lot Number: 2026010690.

Devices named in this recall

6 devices in the FDA device registry whose identifier appears in the recall's code information.

Other devices under the same FDA submission

316 devices cleared under K213481 are not named by identifier in this recall. One submission often covers many models, so they may or may not be affected.

Other products in the same recall event

The FDA groups related products into one recall event (event 98692).

Sources and updates

How recalls are matched to devices · Editorial policy · Report an error on this page