Toggleloc System, Biomet Ziptight Ankle Syndesmosis… recallZ-0559-2010 · Biomet, Inc. · initiated Nov 10, 2009
Terminated All recalls posted in December 2009
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Biomet, Inc. or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Packages labeled as containing a stainless steel device actually contain a titanium device, and vice versa.
FDA root cause category: Labeling mix-ups
What the company is doing
Distributors, hospital consignees and an implanting surgeon were notified of the recall by an Urgent Medical Device Recall Notice, dated 11/10/09. Distributors were instructed to locate and remove the identified products from circulation. The instructions on the enclosed "FAX Back Response Form" should be followed and product from their accounts should be returned. Hospital consignees and the implanting surgeon were informed of the recall and advised of the potential health hazards presented by the mix-up.
Recall details
- Recall number
- Z-0559-2010
- Recall class
- Not yet classified by the FDA
- Status
- Terminated
- Initiated by the company
- Nov 10, 2009
- Posted by the FDA
- Dec 22, 2009
- Recalling firm
- Biomet, Inc.
- Quantity
- 24 of both products.
- Product code
- MBI
- FDA submissions
- K083070
- Distribution
- Nationwide Distribution -- Including states of California, Florida, South Carolina, and Virginia.
Product description
Toggleloc System, Biomet Ziptight Ankle Syndesmosis Fixation System - Titanium with Ziploop Technology, polyethylene/polypropylene/ polyester/TI-6AL-4V alloy/S.S., sterile Biomet Sports Medicine, Warsaw, IN.; REF 909853. A smooth or threaded metallic bone fixation fastener intended to be implanted for fixation of bone fractures.
Code information (models, lots, serial numbers)
Lot 101780.
Other devices under the same FDA submission
9 devices cleared under K083070 — the recall does not name any of them by identifier. One submission often covers many models, so they may or may not be affected.
- ZIPTIGHT FIXATION SYSTEM 904759Biomet Orthopedics, LLC · FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE1 recall23 reports
- ZIPTIGHT 904834Biomet Orthopedics, LLC · FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE1 recall9 reports
- ToggleLoc With Ziploop 904755Biomet Orthopedics, LLC · STAPLE, FIXATION, BONE3 reports
- ToggleLoc With Ziploop 904754Biomet Orthopedics, LLC · STAPLE, FIXATION, BONE3 reports
- ZIPTIGHT FIXATION SYSTEM 909856Biomet Orthopedics, LLC · FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE3 reports
- ToggleLoc With Ziploop 904756Biomet Orthopedics, LLC · STAPLE, FIXATION, BONE1 report
- ToggleLoc with Ziploop 909854Biomet Orthopedics, LLC · FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE1 report
- ZIPTIGHT FIXATION SYSTEM 909857Biomet Orthopedics, LLC · FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE1 report
- ZIPTIGHT 904835Biomet Orthopedics, LLC · FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE1 report
Other products in the same recall event
The FDA groups related products into one recall event (event 53878).
- Z-0560-2010 · TerminatedToggleloc System, Biomet Ziptight Ankle Syndesmosis Fixation System - SS with Ziploop Technology, polyethylene/polypropylene/ polyester/ stainless steel, sterile Biomet Sports Medi…
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 18, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page