ARTOURA Breast Tissue Expander TEXP130RHRecalls & reported problems
Mentor Texas L.P. · Textured, High Profile, Suture Tabs, Integral Injection Dome, 475cc · Class U · Implant
All models of ARTOURA Breast Tissue Expander (28)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 9
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00081317009474), received between Oct 17, 2018 and Mar 28, 2024 — classified as 9 injuries, 1 malfunction.
The most frequently reported specific device problem is “Material Rupture” (6 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Material Rupture6
- Adverse Event Without Identified Device or Use Problem3
- Connection Problem1
- Off-Label Use1
Patient problems
- No Code Available7
- Necrosis1
- No Clinical Signs, Symptoms or Conditions1
- Post Operative Wound Infection1
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
InjuryMar 28, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A 47-YEAR-OLD CAUCASIAN FEMALE PATIENT UNDERWENT PRIMARY BREAST RECONSTRUCTION SURGERY WITH 475CC ARTOURA BREAST TISSUE EXPANDER AND EXPERIENCED WOUND INFECTION ON HER LEFT SIDE POSTOPERATIVELY. THE PATIENT HAS CONSULTED WITH THE HEALTHCARE PROFESSIONAL. THE PATIENT UNDERWENT BILATERAL REPLACEMENT SURGERY WITH CATALOG NUMBER 3502700; SERIAL NUMBER (B)(6) ON THE LEFT SIDE, AND WITH CATALOG NUMBER 3502700; SERIAL NUMBER (B)(6) ON THE RIGHT SIDE ON (B)(6) 2024.
Patient problems: Post Operative Wound Infection
MAUDE report 18999368 ↗MalfunctionNov 9, 2023Connection Problem; Connection Problem
IT WAS REPORTED THAT A 475CC ARTOURA BREAST TISSUE EXPANDER AND AN UNKNOWN MENTOR TISSUE EXPANDER WERE OBSERVED TO HAVE DEFECTIVE VALVES PRIOR TO AN UNSPECIFIED BREAST SURGERY. HOWEVER, THE SURGERY COMMENCED WITHOUT ANY REPORTED DELAYS AND A NEW IMPLANT WAS USED TO COMPLETE THE IMPLANTATION. NO REPORTED ADVERSE EVENTS OR PATIENT OUTCOMES WERE REPORTED. THIS REPORT IS FOR THE FIRST OF TWO IMPLANTS. REFER TO MANUFACTURING REPORT NUMBER 1645337-2023-13351 FOR THE SECOND DEVICE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18107258 ↗InjuryJan 13, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A CAUCASIAN FEMALE PATIENT WHO UNDERWENT A PRIMARY BREAST RECONSTRUCTION WITH 475CC ARTOURA BREAST TISSUE EXPANDER EXPERIENCED RIGHT-SIDED SOFT TISSUE NECROSIS POSTOPERATIVELY. THE PATIENT UNDERWENT EXPLANTATION AND REPLACEMENT WITH 475CC SMOOTH MENTOR MEMORYGEL BREAST IMPLANT, CATALOG # 3504754BC, RIGHT LOT-SERIAL # (B)(4) ON (B)(6) 2016. UPON EXPLANTATION, THE RIGHT BREAST WAS NOTED TO HAVE AN AREA OF OLD HEMATOMA AND POSSIBLE NECROTIC PECTORALIS MUSCLE.
Patient problems: Necrosis
MAUDE report 11159380 ↗InjuryAug 20, 2020Off-Label Use; Material Rupture; Off-Label Use; Material Rupture
IT WAS REPORTED THAT A (B)(6) YEAR OLD FEMALE PATIENT WHO UNDERWENT AN UNSPECIFIED BREAST RECONSTRUCTION WITH 475CC ARTOURA BREAST TISSUE EXPANDER EXPERIENCED POSTOPERATIVE LEFT-SIDED TISSUE EXPANDER DEFLATION. THE PHYSICIAN SUSPECTED DEFLATION UPON PHYSICAL EXAMINATION. AS A RESULT, THE PATIENT UNDERWENT EXPLANTATION ON (B)(6) 2020. FURTHERMORE, OFF-LABEL USE OF THE DEVICE WAS NOTED AS TISSUE EXPANDERS ARE NOT INTENDED FOR USE BEYOND SIX MONTHS.
Patient problems: No Code Available
MAUDE report 10434032 ↗InjuryJan 17, 2020Material Rupture; Material Rupture
IT WAS REPORTED THAT A FEMALE PATIENT UNDERWENT A BREAST SURGERY WITH A 475CC MENTOR ARTOURA BREAST TISSUE EXPANDER AND EXPERIENCED POSTOPERATIVE DEFLATION. AS A RESULT, THE PATIENT'S IMPACTED DEVICE WAS EXPLANTED ON (B)(6) 2019.
Patient problems: No Code Available
MAUDE report 9603704 ↗InjuryJan 15, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON (B)(6) 2019, ARTOURA BREAST TISSUE EXPANDER 475CC WAS RECEIVED BY THE MENTOR FAILURE ANALYSIS LAB WITH NO ACCOMPANYING INFORMATION. THE DEVICE COULD NOT BE ASSOCIATED WITH AN EXISTING COMPLAINT. IN THE ABSENCE OF CLARIFYING INFORMATION, IT CANNOT BE DETERMINED WHY THIS DEVICE WAS RETURNED TO MENTOR. HOWEVER, IT WILL BE CONSERVATIVELY REPORTED TO FDA AS AN EVENT REQUIRING MEDICAL DEVICE REMOVAL FROM A PATIENT.
Patient problems: No Code Available
MAUDE report 9592436 ↗InjuryDec 23, 2019Material Rupture; Material Rupture
IT WAS REPORTED THAT A (B)(6) YEAR-OLD CAUCASIAN FEMALE PATIENT UNDERWENT A BREAST RECONSTRUCTION REVISION WITH ARTOURA BREAST TISSUE EXPANDER 475CC AND EXPERIENCED A DEFLATION ON THE RIGHT SIDE POST-OPERATIVELY, WHICH WAS CONFIRMED BY A PHYSICIAN. AS A RESULT, THE PATIENT UNDERWENT REMOVAL AND REPLACEMENT WITH UNSPECIFIED MENTOR IMPLANTS ON (B)(6) 2019.
Patient problems: No Code Available
MAUDE report 9512084 ↗InjuryDec 10, 2019Material Rupture; Material Rupture
IT WAS REPORTED THAT A (B)(6) YEAR-OLD FEMALE PATIENT UNDERWENT BREAST SURGERY WITH AN ARTOURA BREAST TISSUE EXPANDER 475CC DEVICE THAT DEFLATED AFTER IMPLANTATION. IT WAS OBSERVED DURING EXCHANGE SURGERY ON (B)(6) 2019 THAT THE LEFT SIDE TISSUE EXPANDER WAS DEFLATING AROUND THE PORT. THE DEFLATED EXPANDER WAS REPLACED WITH AN UNSPECIFIED BREAST PROSTHESIS.
Patient problems: No Code Available
MAUDE report 9446220 ↗InjurySep 11, 2019Material Rupture; Material Rupture
IT WAS REPORTED THAT A (B)(6) ASIAN FEMALE WHO UNDERWENT PRIMARY BREAST AUGMENTATION WITH A 475CC ARTOURA BREAST TISSUE EXPANDER EXPERIENCED LEFT SIDED DEFLATION POST PROCEDURE. THE DEFLATION WAS CONFIRMED BY A PHYSICIAN. AS A RESULT, BILATERAL EXPLANT WITH UNKNOWN REPLACEMENT STATUS WAS PERFORMED ON (B)(6) 2019.
Patient problems: No Code Available
MAUDE report 8998288 ↗InjuryOct 17, 2018Material Rupture; Material Rupture
IT WAS REPORTED THAT A (B)(6) CAUCASIAN FEMALE PATIENT UNDERWENT A PRIMARY BREAST RECONSTRUCTION PROCEDURE WITH A MENTOR ARTOURA BREAST TISSUE EXPANDER 475CC DEVICE THAT DEFLATED AFTER IMPLANTATION. THE PATIENT¿S DOCTOR OBSERVED THAT THE LEFT TISSUE EXPANDER WAS LESS FULL. AS A RESULT, THE PATIENT UNDERWENT EXPLANTATION ON (B)(6) 2018.
Patient problems: No Code Available
MAUDE report 7976451 ↗
Other EXPANDER, SKIN, INFLATABLE devices
- B.BRAUN 7B3050B. Braun Medical Inc. · EXPANDER, SKIN, INFLATABLE1 recall40 reports
- MENTOR CPX 4 Breast Tissue Expander with Suture Tabs 3549314Mentor Texas L.P. · EXPANDER, SKIN, INFLATABLE1 recall22 reports
- MENTOR CPX4 PLUS, Smooth, Medium Height SCPX146MHMentor Texas L.P. · Expander, skin, inflatable1 recall18 reports
- Natrelle® Style 133 Tissue Expanders with Suture Tabs 133MX-13-TAllergan, Inc. · Expander, Skin, Inflatable1 recall16 reports
- MENTOR ARTOURA PLUS, Smooth, Ultra High Profile SDC135UHMentor Texas L.P. · Expander, skin, inflatable1 recall14 reports
- MENTOR ARTOURA PLUS, Smooth, High Profile SDC150HMentor Texas L.P. · Expander, skin, inflatable1 recall14 reports
- MENTOR ARTOURA PLUS, Smooth, Ultra High Profile SDC120UHMentor Texas L.P. · Expander, skin, inflatable1 recall14 reports
- Natrelle® Style 133 Tissue Expanders with Suture Tabs 133MV-14-TAllergan, Inc. · Expander, Skin, Inflatable1 recall13 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page