Skip to content

INTERLINK/CONTROL-A-FLO 2C6891Recalls & reported problems

Baxter International Inc. · Extension Set with CONTROL-A-FLO Regulator, Injection Site, Male Luer Lock Adapter with Retractable Collar · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00085412002422), received between Nov 6, 2020 and Mar 30, 2026 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Failure to Prime” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 2 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Prime2
  • Material Rupture2
  • Break1
  • Fluid/Blood Leak1
  • No Flow1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Consequences Or Impact To Patient2
  • No Patient Involvement1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 30, 2026Break; Fluid/Blood Leak

    IT WAS REPORTED THAT FOUR (4) INTERLINK SYSTEM EXTENSION SETS HAD ISSUES DURING PATIENT USE. THE REGULATOR WAS OBSERVED TO BE LEAKING ON THREE INSTANCES. THE LINES WERE OBSERVED TO BE FILLED WITH BLOOD ON TWO OCCASIONS. ADDITIONALLY, WHEN AN IV FLUSH WAS ADMINISTERED AT THE INJECTION SITE, THE REGULATOR BROKE ON TWO INSTANCES. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24717629 ↗
  • MalfunctionJan 16, 2024Material Rupture; Material Rupture

    IT WAS REPORTED THAT AN INTERLINK SYSTEM EXTENSION SET WITH CONTROL-A-FLO REGULATOR RUPTURED WHICH RESULTED IN A FLUID LEAK. THIS EVENT OCCURRED DURING PATIENT THERAPY WITH UNSPECIFIED MEDICATION. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18521497 ↗
  • MalfunctionJan 12, 2024Material Rupture; Material Rupture

    IT WAS REPORTED THAT THEAN INTERLINK SYSTEM EXTENSION SET WITH CONTROL-A-FLO REGULATOR RUPTURED. THIS OCCURRED DURING USE. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18504869 ↗
  • MalfunctionNov 17, 2020No Flow; No Flow

    IT WAS REPORTED THE ¿FLOW METER¿ OF AN UNKNOWN QUANTITY OF INTERLINK SYSTEM EXTENSION SETS WOULD NOT FLOW AND HAD TO BE DISCONNECTED. THE NURSES STATED THAT ¿THE FLOW METER WOULD FLOW ON OPEN BUT WOULD NOT DRIP IF FLOW RATE WAS TURNED UP¿. THIS ISSUE WAS IDENTIFIED DURING PATIENT INFUSIONS. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10853085 ↗
  • MalfunctionNov 17, 2020Failure to Prime; Failure to Prime

    IT WAS REPORTED THAT THE ¿FLOW METER¿ OF AN UNKNOWN QUANTITY OF INTERLINK SYSTEM EXTENSION SETS WOULD NOT PRIME AND HAD TO BE DISCONNECTED. THE NURSES STATED THAT ¿THE FLOW METER WOULD FLOW ON OPEN BUT WOULD NOT DRIP IF FLOW RATE WAS TURNED UP¿. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Patient Involvement

    MAUDE report 10853084 ↗
  • MalfunctionNov 6, 2020Failure to Prime; Failure to Prime

    IT WAS REPORTED THAT THE ¿FLOW METER¿ OF AN UNSPECIFIED QUANTITY, WITHIN THE TEN (10) REPORTED UNITS, OF INTERLINK SYSTEM EXTENSION SETS WITH CONTROL-A-FLO REGULATORS WOULD NOT PRIME AND HAD TO BE DISCONNECTED. THE NURSES STATED THAT ¿THE FLOW METER WOULD FLOW ON OPEN BUT WOULD NOT DRIP IF FLOW RATE WAS TURNED UP¿. THIS ISSUE WAS IDENTIFIED DURING THE PRIMING STEP. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10805003 ↗

Other Set, administration, intravascular devices

All Set, administration, intravascular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page