INTERLINK 2C6720Recalls & reported problems

Baxter International Inc. · Y-Type Blood/Solution Set with Standard Blood Filter, 170 to 260 Micron Filter, Injection Site, Male Luer Lock Adapter · Class 2

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00085412004006), received between Jun 25, 2020 and Oct 2, 2024 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (3 reports).

10 other recalls cover devices cleared under the same FDA submission (K993120); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak3
  • Detachment of Device or Device Component1
  • Disconnection1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 2, 2024Fluid/Blood Leak; Detachment of Device or Device Component; Fluid/Blood Leak; Detachment of Device or Device Component

    IT WAS REPORTED THAT A Y-TYPE BLOOD/SOLUTION SET LEAKED ON THE BENCH TOP. THIS WAS OBSERVED DURING SET UP, AFTER COMPLETION OF THE FILTERING PROCESS WITH BLOOD PRODUCT. A PART OF THE CHAMBER APPEARED TO NOT BE PROPERLY GLUED WHICH RESULTED IN TWO DROPS LEAKING THROUGH THE FILTER. THIS WAS OBSERVED AT THE PART OF THE FILTER WHERE THE INLET TUBING ATTACHES TO THE TOP OF THE FILTER. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20355132 ↗
  • MalfunctionJun 14, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT A Y-TYPE BLOOD/SOLUTION SET LEAKED IN THE Y-TUBING BY THE FILTER. THIS WAS DISCOVERED DURING PATIENT INFUSION OF BONE MARROW PRODUCT. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17126036 ↗
  • MalfunctionJun 25, 2020Disconnection; Fluid/Blood Leak; Disconnection; Fluid/Blood Leak

    IT WAS REPORTED THAT THE TUBING OF A Y-TYPE BLOOD/SOLUTION SET SEPARATED FROM THE SPIKE AND RESULTED IN A LEAK. THIS WAS FURTHER DESCRIBED AS THE END OF THE CLEAR TUBING THAT WENT INTO THE WHITE, HARD, PLASTIC END CAME COMPLETELY OUT. THIS WAS IDENTIFIED DURING A BLOOD TRANSFUSION TO A PATIENT. THE OUTCOME WAS THAT THE BLOOD TRANSFUSION WAS RESCHEDULED FOR THE PATIENT¿S NEXT TREATMENT. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10197186 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K993120. One submission often covers many models, so check the product and lot details in each record.

  • Z-0193-05 · Apr 28, 2004 · Terminated
    Baxter Clearlink Intravenous (IV) Delivery System; the system consists of solution sets, extension sets and blood sets that have a luer activated valve for IV access, which allows
  • Z-1175-03 · Jul 16, 2003 · Terminated
    Fenwal Straight Type Blood Set with Large Standard Blood filter, 15 drops/mL, 80'', 170 to 260 Micron Filter, Injection Site, Male Luer Lock Adapter, catalog 4C6766; Baxter Healthc
  • Z-1160-03 · Jul 16, 2003 · Terminated
    Baxter Y-Type Blood/Solution Set, 10 drops/mL, 112'', Standard Blood Filter, 170 to 260 Micron Filter, Injection Site, Male Luer Lock Adapter, catalog 2C6750; Baxter Healthcare Cor
  • Z-1162-03 · Jul 16, 2003 · Terminated
    Fenwal Y-Type Blood/Solution Set with Large Standard Blood Filter and Pressure Pump, 15 drops/mL, 99'', 170 to 260 Micro Filter, Large Standard Blood Filter, 2 Injection Sites, Mal
  • Z-1178-03 · Jul 16, 2003 · Terminated
    Fenwal 3-Lead Blood/Solution Set with Large Standard Blood Filter, 15 drops/mL, 82'', 170 to 260 Micron Filter, Injection Site, Male Luer Lock Adapter, catalog 4C7784; Baxter Healt
  • Z-1161-03 · Jul 16, 2003 · Terminated
    Clearlink System Y-Type Blood/Solution Set, 10 drops/mL, 112'', Standard Blood Filter, 170 to 260 Micron Filter, Luer Activated Valve, Male Luer Lock Adapter, catalog 2C8750; Baxte
  • Z-1177-03 · Jul 16, 2003 · Terminated
    Fenwal Y-Type Blood/Solution Set with Large Standard Blood Filter, 10 drops/mL, 82'', 170 to 260 Micron Filter, Large Bore Tubing, Male Luer Lock Adapter, catalog 4C7776; Baxter He
  • Z-1172-03 · Jul 16, 2003 · Terminated
    Baxter Y-Type Blood/Solution Set with Pressure Pump, 10 drops/mL, 99'', Large Standard Blood Filter, 170 to 260 Micron Filter, 2 Injection Sites, Male Luer Lock Adapter, catalog 2C
  • Z-1176-03 · Jul 16, 2003 · Terminated
    Fenwal Y-Type Blood/Solution Set with Large Standard Blood Filter, 15 drops/mL, 107'', 2 Injection Sites, Male Luer Lock Adapter, catalog 4C7774; Baxter Healthcare Corporation, Dee
  • Z-1171-03 · Jul 16, 2003 · Terminated
    Baxter Y-Type Blood/Solution Set, 10 drops/mL, 115'', 80 Micron Filter, Injection Site, Male Luer Lock Adapter, catalog 2C7617; Baxter Healthcare Corporation, Deerfield, IL 60015 U

Other Set, blood transfusion devices

All Set, blood transfusion devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.