INTERLINK 2C7557Recalls & reported problems

Baxter Healthcare Corporation · Vented Paclitaxel Set, Polyethylene Lined Tubing, Non-DEHP Pump Segment, 0.2 Micron Filter Injection Site, Male Luer Lock Adapter · Class 2

All models of INTERLINK (10)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
10
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00085412036373), received between Apr 16, 2018 and Dec 30, 2025 — classified as 10 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (5 reports).

5 other recalls cover devices cleared under the same FDA submission (K160007, K981792); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak5
  • Crack2
  • Cut In Material1
  • Improper Flow or Infusion1
  • Material Puncture/Hole1
  • No Flow1

Patient problems

  • No Consequences Or Impact To Patient5
  • No Clinical Signs, Symptoms or Conditions4
  • No Patient Involvement1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 30, 2025Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT TWO (2) INTERLINK SYSTEM VENTED SOLUTION SETS LEAKED FROM THE VENTED FILTER NEAR THE SPIKE. THIS WAS OBSERVED 36 HOURS INTO A 48-HOUR INFUSION. THE DEVICE CONTAINED BLINCYTO. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23922216 ↗
  • MalfunctionJun 18, 2024Crack; Crack

    IT WAS REPORTED THAT A VENTED PACLITAXEL SET HAD A CRACK IN THE TUBING RESULTING IN A CHEMOTHERAPY SPILL. THIS WAS OBSERVED WHEN THE CHEMOTHERAPY WAS HUNG AND PUT THROUGH AN UNSPECIFIED INTRAVENOUS (IV) PUMP. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19559553 ↗
  • MalfunctionApr 23, 2024Crack; Fluid/Blood Leak; Crack; Fluid/Blood Leak

    IT WAS REPORTED THAT THE TUBING OF A VENTED PACLITAXEL SET CRACKED. THIS WAS OBSERVED DURING SETUP, WHEN CHEMOTHERAPY WAS HUNG AND THE SET WAS PUT THROUGH THE INTRAVENOUS (IV) PUMP; THE TUBING STARTED TO CRACK RESULTING IN LEAKAGE. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19168626 ↗
  • MalfunctionMay 6, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT TWO (2) VENTED PACLITAXEL SETS WERE LEAKING. THE LEAK WAS FURTHER DESCRIBED AS, ¿LEAKED DILUENT THROUGH THE WHITE TUBING CONNECTOR PIECE ADJACENT TO THE FILTER¿. THE LEAKS OCCURRED WHILE PRIMING THE SETS WITH DILUTANT PRIOR TO PATIENT USE. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14311266 ↗
  • MalfunctionFeb 9, 2021Improper Flow or Infusion; Improper Flow or Infusion

    IT WAS REPORTED AN UNSPECIFIED QUANTITY OF VENTED PACLITAXEL SETS HAD BUBBLES WHICH IS INDICATIVE OF AIR IN THE LINE. THIS ISSUE WAS IDENTIFIED DURING PATIENT INFUSIONS. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 11302606 ↗
  • MalfunctionAug 14, 2020Material Puncture/Hole; Material Puncture/Hole

    IT WAS REPORTED THAT A VENTED PACLITAXEL SET LEAKED DUE TO "A SMALL HOLE IN THE TUBING FROM WHERE THE CLAMP WAS". THIS ISSUE WAS IDENTIFIED AFTER PRIMING WHEN THE NURSE WAS SETTING UP THE INFUSION PRIOR TO PATIENT USE. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10407793 ↗
  • MalfunctionJun 4, 2020No Flow; No Flow

    IT WAS REPORTED THAT A QUANTITY (AT LEAST SEVEN) OF VENTED PACLITAXEL SETS WOULD NOT FLOW AFTER SPIKING TO UNKNOWN BAGS. THIS WAS DISCOVERED DURING MIXING IN THE PHARMACY. THERE WERE NO SIGNS OF PHYSICAL DAMAGE TO THE PRODUCT OR SHIPPING PACKAGING. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Patient Involvement

    MAUDE report 10119540 ↗
  • MalfunctionFeb 27, 2020Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED A VENTED PACLITAXEL SET LEAKED IN CONJUNCTION WITH A 250ML VIAFLO BAG. THE LEAK WAS OBSERVED FROM "WHERE THE SPIKE WAS INSERTED INTO THE BAG". THIS EVENT WAS IDENTIFIED DURING USE. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9765265 ↗
  • MalfunctionApr 16, 2018Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT A VENTED PACLITAXEL SET LEAKED. DURING PATIENT INFUSION WITH DOCETAXEL (RATE OF 262ML OVER ONE HOUR), A LEAK WAS OBSERVED ¿AROUND THE FILTER AT THE END OF THE FILTER¿. THE EVENT OCCURRED APPROXIMATELY 40 MINUTES INTO THE INFUSION VIA AN UNSPECIFIED PUMP. THE DRUG LEAKED ONTO THE FLOOR UNDER THE BAG. A CHEMO SPILL KIT WAS USED FOR CLEANUP. THERE WAS NO UNINTENDED DRUG EXPOSURE TO THE PATIENT OR CLINICIAN. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7432878 ↗
  • MalfunctionApr 16, 2018Cut In Material; Cut In Material

    IT WAS REPORTED THAT THE BLUE SLIDE CLAMP OF A VENTED PACLITAXEL SET SEVERED THE TUBING WHICH RESULTED IN A LEAK. THE SLIDE CLAMP SEVERED THE TUBING DURING PATIENT SETUP. THE LINE HAD BEEN PRIMED AND THE PATIENT WAS CONNECTED FOR THERAPY WHEN THE SEVERED TUBING WAS IDENTIFIED. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7432504 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K160007, K981792. One submission often covers many models, so check the product and lot details in each record.

  • Z-0618-2007 · Feb 16, 2007 · Terminated
    Baxter Clearlink System Vented Paclitaxel Set; a sterile fluid pathway with polyethylene lined tubing, non-DEHP 12 inch pump segment, 0.22 micron downstream high pressure filter, L
  • Z-0619-2007 · Feb 16, 2007 · Terminated
    Baxter Interlink System Vented Paclitaxel Set; a sterile fluid pathway with polyethylene lined tubing, non-DEHP pump segment, 0.22 micron downstream high pressure filter, injection
  • Z-0620-2007 · Feb 16, 2007 · Terminated
    Baxter Vented Paclitaxel Set; a sterile fluid pathway with polyethylene lined tubing, non-DEHP pump segment, 0.22 micron downstream high pressure filter, injection site, male Luer
  • Z-0193-05 · Apr 28, 2004 · Terminated
    Baxter Clearlink Intravenous (IV) Delivery System; the system consists of solution sets, extension sets and blood sets that have a luer activated valve for IV access, which allows
  • Z-1158-03 · Jul 16, 2003 · Terminated
    Clearlink System Vented Paclitaxel Set, 10 drops/mL, 111'', Polyethylene Lined Tubing, Non-DEHP Pump Segment, 0.22 Micron Extended Life Filter, Luer Activated Valve, Male Luer Lock

Other Set, administration, intravascular devices

All Set, administration, intravascular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page