Skip to content

DJO SURGICAL 508-65-030Recalls & reported problems

Encore Medical, L.P. · ALTIVATE REVERSE MODULAR CENTRAL SCREW, 6.5 X 30mm · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00190446829713), received between May 21, 2025 and Jan 7, 2026 — classified as 2 injuries.

The most frequently reported specific device problem is “Mechanical Problem” (1 report).

8 other recalls cover devices cleared under the same FDA submission (K233481); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Mechanical Problem1
  • Patient Device Interaction Problem1

Patient problems

  • Failure of Implant1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 7, 2026Patient Device Interaction Problem

    REVISION SURGERY - BASEPLATE AND CENTRAL SCREW ARE NOT FULLY SEATING AND LOCK TOGETHER CAUSING FUNCTIONALITY CONCERNS.

    Patient problems: Failure of Implant

    MAUDE report 24000042 ↗
  • InjuryMay 21, 2025Mechanical Problem; Mechanical Problem

    COMPLAINT - THE CENTER SCREW IS NOT GOING IN "PROPERLY" INTO THE BASEPLATE, CAUSING A COLD WELDING OFF ACCESS. SURGEON REMOVED FROM PATIENT AND IMPLANTED ANOTHER IMPLANT WHICH WAS SUCCESSFUL BY USING A DIFFERENT TECHNIQUE. THIS CAUSED A 30-40 MINUTE DELAY IN SURGERY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22066789 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K233481. One submission often covers many models, so check the product and lot details in each record.

  • Z-2548-2025 · Jul 18, 2025 · Open, Classified
    Brand Name: DJO SURGICAL Product Name: ALTIVATE REVERSE WEDGE GLENOID REAMER SLEEVE Model/Catalog Number: 804-06-310 Product Description: Material: S.S/CoCrMo, Non-Sterile
  • Z-2547-2025 · Jul 18, 2025 · Open, Classified
    Brand Name: DJO SURGICAL Product Name: ALTIVATE REVERSE WEDGE GLENOID REAMER BOSS DRILL, 6.5mm Model/Catalog Number: 804-06-312 Product Description: Material: S.S., Non Sterile
  • Z-2546-2025 · Jul 18, 2025 · Open, Classified
    Brand Name: DJO SURGICAL Product Name: ALTIVATE REVERSE WEDGE GLENOID REAMER HEAD Model/Catalog Number: 804-06-311 Product Description: Material: S.S/Nitronic, Non-Sterile
  • Z-2549-2025 · Jul 18, 2025 · Open, Classified
    Brand Name: DJO SURGICAL Product Name: FA S Altivate Reverse Glenoid Tray Model/Catalog Number: None Software Version: NA Product Description: Enovis" shoulder devices are intended
  • Z-2010-2025 · May 28, 2025 · Open, Classified
    Brand Name: ALTIVATE REVERSE Product Name: ALTIVATE REVERSE TORX PERIPHERAL SCREW, 18mm Model/Catalog Number: 506-04-118 Software Version: NA Product Description: Encore Medical L.
  • Z-2009-2025 · May 28, 2025 · Open, Classified
    Brand Name: ALTIVATE REVERSE Product Name: ALTIVATE REVERSE TORX PERIPHERAL SCREW, 22mm Model/Catalog Number: 506-04-122 Software Version: NA Product Description: Encore Medical L.
  • Z-2011-2025 · May 28, 2025 · Open, Classified
    Brand Name: ALTIVATE REVERSE Product Name: ALTIVATE REVERSE TORX PERIPHERAL SCREW, 30mm Model/Catalog Number: 506-04-130 Software Version: NA Product Description: Encore Medical L.
  • Z-2008-2025 · May 28, 2025 · Open, Classified
    Brand Name: ALTIVATE REVERSE Product Name: ALTIVATE REVERSE TORX PERIPHERAL SCREW, 26mm Model/Catalog Number: 506-04-126 Software Version: NA Product Description: Encore Medical L.

Other PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices

All PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices →

Sources and updates