ACS AHPO55JRecalls & reported problems
American Contract Systems, Inc. · OUTPATIENT PORT ACCESS KIT 307907 · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
No MAUDE adverse event reports in our data reference this device identifier directly.
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Nov 29, 2023Class IIOpen, Classified
During an internal investigation, ACS identified that several components were "piggybacked" to ACS trays and subjected to the ACS sterilization process. There is no supporting documentation stating the "piggybacked" components were assessed to determine if they were suitable for exposure to elevated temperatures for an extended period of time and further exposure to sterilization. As a result, the piggybacked components may (1) have a loss/lack of functionality, (2) loss of drug efficacy, if applicable, and (3) may have had higher than specified EO residuals.
Z-0825-2024 · Root cause: Process control · Recall details · FDA record ↗
Other General surgery tray devices
- Halyard MSBM036-03_0012Avid Medical, Inc. · General surgery tray5 recalls0 reports
- Medline Industries, Inc. DYNJ58534Medline Industries, Inc. · General surgery tray5 recalls0 reports
- Medline Industries, Inc. DYNJ82007AMedline Industries, Inc. · General surgery tray4 recalls0 reports
- Medline Industries, Inc. DYNJ42382BMedline Industries, Inc. · General surgery tray4 recalls0 reports
- Centurion ART690Centurion Medical Products Corporation · General Surgery Tray4 recalls0 reports
- Medline Industries, Inc. DYNJ44866PMedline Industries, Inc. · General surgery tray4 recalls0 reports
- Medline Industries, Inc. DYNDL1350AMedline Industries, Inc. · General surgery tray4 recalls0 reports
- Medline Industries, Inc. DYNJ69692Medline Industries, Inc. · General surgery tray4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page