Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00191506015466), received between Oct 18, 2023 and May 2, 2025 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Crack” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Crack1
  • Fluid/Blood Leak1
  • Leak/Splash1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 2, 2025Crack; Fluid/Blood Leak

    ONE OF THE CORDS FOR THE EKOS [EKOSONIC ENDOVASCULAR SYSTEM] HAD A CRACK IN IT AND WAS LEAKING FLUID AT ONE OF THE CONNECTIONS. WE HAD TO OPEN A NEW PRODUCT, TAKE OUT THE BROKEN ONE AND RE-INSERT THE NEW ONE. NO HARM TO PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21950048 ↗
  • InjuryJul 22, 2024Leak/Splash; Adverse Event Without Identified Device or Use Problem; Leak/Splash; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE DRUG PORT LEAKED, REQUIRING AN ADDITIONAL DEVICE. ONE 106CM 12 CM EKOS PLUS CATHETER AND ONE 135CM 16 CM EKOS PLUS CATHETER WERE SELECTED FOR USE. DURING THE PROCEDURE, BOTH EKOS CATHETERS WERE PLACED IN THE PATIENT AND HOOKED UP TO THE APPROPRIATE PUMPS. AFTER EVERYTHING WAS CONNECTED, IT WAS DETERMINED THAT ONE OF THE CATHETERS HAD MOVED INSIDE THE PATIENT AND NEEDED TO BE REPOSITIONED. ALL LINES WERE THEN DISCONNECTED, THE CATHETER WAS REPOSITIONED AND EVERYTHING WAS HOOKED BACK UP AGAIN. THE PATIENT WAS MOVED TO THE INTENSIVE CARE UNIT (ICU) AND IT WAS NOTICED THAT BOTH DRUG LUMEN PORTS WERE LEAKING FLUID AT THE CONNECTOR. THE PATIENT WAS BROUGHT BACK TO THE LAB AND THE ORIGINAL CATHETERS WERE REMOVED AND TWO NEW EKOS CATHETERS WERE PLACED WITHOUT ISSUE. THERE WERE NO PATIENT COMPLICATIONS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19793615 ↗
  • MalfunctionOct 18, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REPORTABLE BASED ON DEVICE ANALYSIS COMPLETED ON 28SEP2023. AN EKOS+ ENDOVASCULAR DEVICE WAS RETURNED TO THE COMPLAINT INVESTIGATION SITE WITHOUT AN ASSOCIATED COMPLAINT. DEVICE ANALYSIS REVEALED THAT THE COOLANT AND DRUG LUERS WERE CRACKED AND LEAKING. BASED ON THE CONDITION OF THE RETURNED DEVICE, THE DEVICE WAS USED DURING A PROCEDURE. NO FURTHER INFORMATION WAS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17962443 ↗

FDA clearance and classification

The FDA regulates product code KRA (catheter, continuous flush) under 21 CFR 870.1210 as a Class II device. 21 CFR 870.1210 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the EKOS™ + H74939605106120

Has the EKOS™ + H74939605106120 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00191506015466), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the EKOS™ + H74939605106120?

The FDA's MAUDE database lists 3 adverse event reports for this device, received between Oct 18, 2023 and May 2, 2025. In those reports, the most common specific device problems are “Crack” (1), “Fluid/Blood Leak” (1) and “Leak/Splash” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the EKOS™ + H74939605106120?

None of the reports are classified as deaths, 1 as an injury and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the EKOS™ + H74939605106120, and is it still sold?

The FDA's device database lists Boston Scientific Corporation as the company responsible for it (brand EKOS™ +, model H74939605106120). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Catheter, continuous flush devices

All Catheter, continuous flush devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page