Senographe Pristina POZ2Recalls & reported problems

Ge Medical Systems · Senographe Pristina UDI · Class 2

All models of Senographe Pristina (9)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

2 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
0
Deaths reported
0
Injuries reported
0
Recalls naming it
2

Summary

No MAUDE adverse event reports in our data reference this device identifier directly.

2 FDA recall records name this device's identifier, 2 still open.

4 other recalls cover devices cleared under the same FDA submission (K162268, K260087, P130020); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Aug 28, 2026Class IIOpen, Classified

    GE HealthCare has become aware of a nonconformance to certain Senographe Pristina VIA systems. Specifically, in cases of 3D+2D manual mode where the acquisition configuration of the anode track/filter combination is different, it can result in the following: the collimator blades might be visible in the image, or the collimator might be open more than expected, and an incorrect collimator filter might be used with respect to the anode track selected This issue could result in a minor additional X-ray dose being delivered to the patient and obvious artifacts in the image (collimator blades).

    Z-0326-2027 · Root cause: Radiation Control for Health and Safety Act · Recall details · FDA record ↗

  2. Aug 28, 2026Class IIOpen, Classified

    GE HealthCare has become aware of a nonconformance to certain Senographe Pristina VIA systems. Specifically, in cases of 3D+2D manual mode where the acquisition configuration of the anode track/filter combination is different, it can result in the following: the collimator blades might be visible in the image, or the collimator might be open more than expected, and an incorrect collimator filter might be used with respect to the anode track selected This issue could result in a minor additional X-ray dose being delivered to the patient and obvious artifacts in the image (collimator blades).

    Z-0327-2027 · Root cause: Radiation Control for Health and Safety Act · Recall details · FDA record ↗

FDA clearance and classification

Cleared through 510(k) K260087 on Mar 24, 2026 (decision: Substantially Equivalent). Submitted by GE Medical Systems SCS as “Senographe Pristina; SenoBright HD; Pristina Serena; Pristina Serena Bright”. The FDA review took 71 days. FDA record ↗

Cleared through 510(k) K162268 on Nov 3, 2016 (decision: Substantially Equivalent). Submitted by GE Healthcare as “Senographe Pristina”. The FDA review took 83 days. FDA record ↗

Approved through premarket approval (PMA) P130020 on Aug 26, 2014. Submitted by GE Healthcare as “Senoclaire”. The FDA review took 405 days. The FDA has since approved 5 supplements (changes to the device or its labeling), most recently on Nov 21, 2025. FDA record ↗

The FDA regulates product code MUE (full field digital, system, x-ray, mammographic) under 21 CFR 892.1715 as a Class II device. 21 CFR 892.1715 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K162268, K260087, P130020. One submission often covers many models, so check the product and lot details in each record.

  • Z-0328-2027 · Aug 28, 2026 · Open, Classified
    Senographe Pristina 3D
  • Z-0875-2026 · Oct 24, 2025 · Open, Classified
    Senographe Pristina, Pristina Serena, and Pristina Serena 3D. for screening and diagnostic mammography
  • Z-0862-2024 · Dec 26, 2023 · Open, Classified
    Senographe Pristina
  • Z-2131-2019 · May 16, 2019 · Terminated
    GE Senographe Pristina - Product Usage: Senographe Pristina generates digital mammographic images that can be used for screening and in the diagnosis of breast cancer. Senographe P

Common questions about the Senographe Pristina POZ2

Has the Senographe Pristina POZ2 been recalled?

Yes. 2 FDA recall records name this device's identifier: 2 still open. The most recent, Z-0326-2027 (Class II), began on Aug 28, 2026: GE HealthCare has become aware of a nonconformance to certain Senographe Pristina VIA systems. Specifically, in cases of 3D+2D manual mode where the acquisition configuration of the anode track/filter combination is… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

Is the Senographe Pristina POZ2 FDA approved?

It was approved through premarket approval (PMA) P130020 on Aug 26, 2014; its record lists 3 FDA submissions in total.

Who makes the Senographe Pristina POZ2, and is it still sold?

The FDA's device database lists Ge Medical Systems as the company responsible for it (brand Senographe Pristina, model POZ2). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Full Field Digital, System, X-Ray, Mammographic devices

All Full Field Digital, System, X-Ray, Mammographic devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page