CONTOUR® 9556CRecalls & reported problems
Ascensia Diabetes Care US Inc. · Blood Glucose Monitoring System. For self-testing, monitoring and management of blood glucose. Contents: CONTOUR® Blood Glucose Meter; Quick Reference Guide; User Guide; Log Book; Carrying Case; Warranty Card. · Class 2
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00301939556010), received between Aug 17, 2018 and Nov 21, 2025 — classified as 10 malfunctions.
The most frequently reported specific device problem is “Missing Test Results” (6 reports).
2 other recalls cover devices cleared under the same FDA submission (K062058); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Missing Test Results6
- Incorrect, Inadequate or Imprecise Result or Readings2
- High Readings1
- Nonstandard Device1
Patient problems
- No Known Impact Or Consequence To Patient7
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 21, 2025Nonstandard Device; Nonstandard Device
A CUSTOMER REPORTED THAT SHE PURCHASED THE CONTOUR® METER FROM THEIR LOCAL PHARMACY IN THE US, WHICH WAS DISPLAYING THE UNITS OF MEASUREMENT ACCOMPANIED WITH THE BLOOD GLUCOSE READINGS IN MMOL/L INSTEAD OF MG/DL. THERE WAS NO ALLEGATION OF AN ADVERSE EVENT. A REPLACEMENT METER KIT WAS SENT TO THE CUSTOMER. THE DEVICE IS NOT EXPECTED TO BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23619657 ↗MalfunctionMar 24, 2025Missing Test Results; Missing Test Results
THE CUSTOMER CALLED ASCENSIA CUSTOMER SERVICE TO SEEK ASSISTANCE WITH THE ASCENSIA METER. DURING TROUBLESHOOTING, IT WAS FOUND THAT THE CUSTOMER'S BLOOD GLUCOSE READINGS WERE NOT BEING STORED IN THE MEMORY OF THE CONTOUR® METER. THERE WAS NO ALLEGATION OF AN ADVERSE EVENT. THE CUSTOMER WAS ADVISED TO RETURN THE DEVICE FOR EVALUATION. A REPLACEMENT METER KIT WAS SENT TO THE CUSTOMER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21677303 ↗MalfunctionMay 25, 2021Missing Test Results; Missing Test Results
THE CUSTOMER REPORTED THAT HER BLOOD GLUCOSE READINGS WERE NOT BEING STORED IN THE MEMORY OF THE CONTOUR METER. THERE WAS NO ALLEGATION OF AN ADVERSE EVENT. THE CUSTOMER WAS ADVISED TO RETURN THE DEVICE FOR EVALUATION. REPLACEMENT METER KIT AND TEST STRIPS WERE SENT TO THE CUSTOMER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11877582 ↗MalfunctionJun 4, 2020Missing Test Results; Missing Test Results
THE CUSTOMER REPORTED THAT HIS BLOOD GLUCOSE READINGS WERE NOT BEING STORED IN THE MEMORY OF THE CONTOUR METER. THERE WAS NO ALLEGATION OF AN ADVERSE EVENT. THE CUSTOMER WAS ADVISED TO RETURN THE DEVICE FOR EVALUATION. A REPLACEMENT METER KIT WAS SENT TO THE CUSTOMER.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10119018 ↗MalfunctionMar 26, 2020Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER REPORTED THAT THERE WAS A DIFFERENCE OF 20 TO 30 MG/DL BETWEEN THE BLOOD GLUCOSE READINGS OBTAINED ON THE CONTOUR METER AND ANOTHER METER. NO SPECIFIC READINGS WERE PROVIDED. THERE WAS NO ALLEGATION OF AN ADVERSE EVENT. THE CUSTOMER WAS ADVISED TO RETURN THE DEVICE FOR EVALUATION. REPLACEMENT METER AND TEST STRIPS WERE SENT TO THE CUSTOMER. SINCE THE STRIP INFORMATION WAS NOT PROVIDED, THIS REPORT WILL BE SUBMITTED UNDER THE METER INFORMATION.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9884199 ↗MalfunctionFeb 3, 2020Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER REPORTED THAT AT 7:55 A.M., SHE OBTAINED A BLOOD GLUCOSE READING OF 291 MG/DL ON HER CONTOUR METER. SHE PERFORMED ANOTHER TEST AT 8:00 A.M. WITH HER CONTOUR NEXT ONE METER AND OBTAINED A READING OF 127 MG/DL. THERE WAS NO ALLEGATION OF AN ADVERSE EVENT. THE CUSTOMER WAS ADVISED TO RETURN THE PRODUCT FOR EVALUATION. REPLACEMENT METER AND TEST STRIPS WERE SENT TO THE CUSTOMER. SINCE THE STRIP INFORMATION WAS NOT PROVIDED, THIS REPORT WILL BE SUBMITTED UNDER THE METER INFORMATION.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9658936 ↗MalfunctionJan 7, 2020Missing Test Results; Missing Test Results
THE CUSTOMER REPORTED THAT HIS BLOOD GLUCOSE READINGS AND 14 DAYS AVERAGE WERE NOT BEING STORED IN THE MEMORY OF THE CONTOUR METER. DURING THE CALL, IT WAS FOUND THAT THE DATE AND TIME ON THE METER WERE SET INCORRECTLY. THERE WAS NO ALLEGATION OF AN ADVERSE EVENT. THE CUSTOMER WAS ADVISED TO RETURN THE METER WAS EVALUATION. A REPLACEMENT METER KIT WAS SENT TO THE CUSTOMER.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9558540 ↗MalfunctionSep 25, 2019Missing Test Results; Missing Test Results
THE CUSTOMER REPORTED THAT HIS BLOOD GLUCOSE READINGS WERE NOT BEING STORED IN THE MEMORY OF THE CONTOUR METER. THERE WAS NO ALLEGATION OF AN ADVERSE EVENT. THE CUSTOMER WAS ADVISED TO RETURN THE METER FOR EVALUATION. A REPLACEMENT METER WAS SENT TO THE CUSTOMER.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9118447 ↗MalfunctionAug 1, 2019High Readings; High Readings
THE PARAMEDICS CALLED TO REPORT THAT THEY PERFORMED A BLOOD GLUCOSE TEST ON A PATIENT WITH THEIR CONTOUR METER AND OBTAINED A READING OF 98 MG/DL. UPON REPEAT TESTING WITH THE HOSPITAL'S METER, A READING OF 36 MG/DL WAS OBTAINED. NO FURTHER EVENT DETAILS WERE PROVIDED. THERE WAS NO ALLEGATION OF AN ADVERSE EVENT. NO FOLLOW-UP COULD BE ESTABLISHED WITH THE PARAMEDICS, THEREFORE, NO REPLACEMENT PRODUCT WAS SENT. THE DEVICE IS NOT EXPECTED TO BE RETURNED. SINCE THE STRIP INFORMATION WAS NOT PROVIDED, THIS REPORT WILL BE SUBMITTED UNDER THE METER INFORMATION.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8850236 ↗MalfunctionAug 17, 2018Missing Test Results; Missing Test Results
THE CUSTOMER INITIALLY CALLED FOR ASSISTANCE WITH SUSPECTED HIGH READINGS. THE COMPLAINT DID NOT MEET THE CRITERIA TO BE REPORTED. DURING THE CALL WHEN ACCESSING THE MEMORY TO VIEW THE READINGS, THE CUSTOMER WAS NOT ABLE TO FIND THE READINGS, AND ALLEGED THE CONTOUR WAS NOT RETAINING THEM. NO ADVERSE EVENT WAS ALLEGED. THE CUSTOMER WAS ADVISED TO RETURN THE METER FOR EVALUATION. A NEW METER WAS SENT TO HER.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7794682 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K062058. One submission often covers many models, so check the product and lot details in each record.
- Z-3268-2011 · Aug 12, 2011 · TerminatedContour, Contour TS Blood Glucose Test Strips and Bonus Packs Intended for self-testing by people with diabetes and healthcare professionals to monitor glucose concentrations in w
- Z-1001-2007 · Jun 6, 2007 · TerminatedAscensia Contour Blood Glucose Monitoring System ( Bayer )Diabetes Care System; Product 7152A.---NO USA Units are affected---.
Other Glucose Dehydrogenase, Glucose devices
- OneTouch Verio IQ 022-275LifeScan Europe GmbH · Glucose dehydrogenase, glucose6,035 reports
- OneTouch Verio 022-659LifeScan Europe GmbH · Glucose dehydrogenase, glucose4,219 reports
- TRUE METRIX TRUE METRIX SELF MONITORING BLOOD GLUCOSE TEST STRIPS - 50 Test StripsTrividia Health, Inc. · Glucose Dehydrogenase, Glucose2 deaths2,548 reports
- FreeStyle Lite 70805Abbott Diabetes Care Inc · Glucose dehydrogenase, glucose2,366 reports
- FreeStyle Freedom Lite 70920Abbott Diabetes Care Inc · Glucose dehydrogenase, glucose1,037 reports
- FreeStyle Freedom Lite 70914Abbott Diabetes Care Inc · Glucose dehydrogenase, glucose760 reports
- Accu-Chek Guide 08256292001Roche Diagnostics Operations, Inc. · Glucose Dehydrogenase, Glucose476 reports
- ACCU-CHEK AVIVA PLUS 06908268001Roche Diagnostics Operations, Inc. · Glucose Dehydrogenase, Glucose472 reports