Artegraft Vascular Graft AG 630Recalls & reported problems
Lemaitre Vascular, Inc. · 5mm x 30cm · Class 3 · Implant
All models of Artegraft Vascular Graft (15)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00316837000220), received between Mar 22, 2016 and Mar 22, 2016 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Device Packaging Compromised” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Sep 2, 2025Class IIOpen, Classified
The bovine carotid arteries used to produce the impacted grafts from affected lots were sourced using raw material from a supplier that had not been reviewed and approved by the appropriate regulatory authority.
Z-0034-2026 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗
Most reported problems
Device problems
- Device Packaging Compromised1
- Leak/Splash1
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 22, 2016Device Packaging Compromised; Device Packaging Compromised
ARTEGRAFT INC. RECEIVED AN EMAIL COMMUNICATION FROM AN AUTHORIZED DISTRIBUTOR (WHO WAS PRESENT WITH THE DOCTOR DURING THE PROCEDURE) ON BEHALF OF THE HOSPITAL, THAT AN ARTEGRAFT (COLLAGEN VASCULAR GRAFT) STORAGE TUBE APPEARED TO HAVE LEAKED STORAGE LIQUID, AS "THE LABEL ON THE TUBE WAS SMEARED AND THE LEVEL OF FLUID IN THE BOTTLE WAS LOW". UPON FOLLOW UP COMMUNICATIONS, THE DISTRIBUTOR STATED THAT THE STORAGE TUBE WAS REMOVED FROM THE SEALED PACKAGE AT THE HOSPITAL AND IT WAS NOTICED THAT THE RED ARTEGRAFT LOGO ON THE STORAGE TUBE LABEL APPEARED TO BE "SMEARED". ALSO, THE TAMPER SLEEVE WAS STILL INTACT AND THE VOLUME OF STORAGE LIQUID IN THE TUBE WAS SLIGHTLY LESS THAN PREVIOUSLY SEEN WITH OTHER ARTEGRAFT PRODUCTS; THE CAP SEEMED TO BE AS TIGHT AS OTHER GRAFTS PREVIOUSLY OPENED. IT WAS CONFIRMED THAT THE HOSPITAL STORES THE PRODUCT STANDING UPRIGHT WITH THE LABEL END UP RATHER THAN LYING FLAT, LENGTHWISE. IT WAS ALSO STATED THAT WHEN COMPARED SIDE BY SIDE TO ANOTHER GRAFT WITH THE SAME PRODUCT CODE, THE GRAFT INNER DIAMETER APPEARED "MUCH SMALLER" THAN THE SIZE ON THE LABEL (5 MM ID) OR THE SECOND GRAFT INNER DIAMETER MAY HAVE BEEN LARGER THAN 5 MM. THIS GRAFT WAS IMPLANTED AND THE
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 5517753 ↗MalfunctionMar 22, 2016Leak/Splash; Leak/Splash
ARTEGRAFT INC. RECEIVED AN EMAIL COMMUNICATION FROM AN AUTHORIZED DISTRIBUTOR (WHO WAS PRESENT WITH THE DOCTOR DURING THE PROCEDURE) THAT AN ARTEGRAFT (COLLAGEN VASCULAR GRAFT) WAS IDENTIFIED AS LEAKING DURING THE PRE-IMPLANT PRESSURE TESTING PER THE CORRESPONDING ARTEGRAFT IFU. UPON FOLLOW UP COMMUNICATIONS, THE DISTRIBUTOR STATED THAT NO HOLE WAS VISIBLE BUT RATHER IT APPEARED THAT THE GRAFT WALL WAS "LEAKING AND THINNER THAN USUAL". IT WAS ALSO STATED THAT WHEN COMPARED SIDE BY SIDE, EITHER THE GRAFT INNER DIAMETER MAY HAVE BEEN LARGER, OR ANOTHER GRAFT'S INNER DIAMETER WAS "MUCH SMALLER" THAN THE SIZE ON THE LABEL (5 MM ID). THIS GRAFT WAS NOT IMPLANTED. ANOTHER ARTEGRAFT (AG630 PRODUCT CODE) WAS UTILIZED TO COMPLETE THE PROCEDURE. THE PATIENT IS REPORTED TO BE IN STABLE CONDITION.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 5517739 ↗
Other Tissue Graft Of 6mm And Greater devices
- Artegraft Vascular Graft AG 740Lemaitre Vascular, Inc. · Tissue Graft Of 6mm And Greater2 recalls5 reports
- Artegraft Vascular Graft AG 1015Lemaitre Vascular, Inc. · Tissue Graft Of 6mm And Greater2 recalls0 reports
- Artegraft Vascular Graft AG 636Lemaitre Vascular, Inc. · Tissue Graft Of 6mm And Greater1 recall5 reports
- Artegraft Vascular Graft AG 640Lemaitre Vascular, Inc. · Tissue Graft Of 6mm And Greater1 recall4 reports
- Artegraft Vascular Graft AG 730Lemaitre Vascular, Inc. · Tissue Graft Of 6mm And Greater1 recall3 reports
- Artegraft Vascular Graft AG 750Lemaitre Vascular, Inc. · Tissue Graft Of 6mm And Greater1 recall2 reports
- Artegraft Vascular Graft AG 745Lemaitre Vascular, Inc. · Tissue Graft Of 6mm And Greater1 recall2 reports
- Artegraft Vascular Graft AG 616Lemaitre Vascular, Inc. · Tissue Graft Of 6mm And Greater1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page