CONSTELLATION 8065753041Recalls & reported problems
Alcon Laboratories, Inc. · CONSTELLATION TABLE TOP · Class 2
All models of Constellation (13)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
Quick summary
This Alcon Constellation eye surgery system is used in procedures such as vitrectomy, and its 510 reports often describe the cutting blade failing to cut, power output problems, and weak suction. Some describe a light source failing before cataract surgery. There are no deaths and 35 injuries reported, some involving eye pressure dropping or endophthalmitis, an eye infection. No recalls name this device, and reports fell to 77 in the past year from 149 the year before.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 498
- Deaths reported
- 0
- Injuries reported
- 35
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 498 adverse event reports that list this exact device (DI 00380657530410), received between Mar 26, 2021 and Sep 22, 2026 — classified as 35 injuries, 463 malfunctions.
The most frequently reported specific device problem is “Failure to Cut” (99 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Cut99
- Appropriate Device Problem Term/Code Not Available67
- Energy Output Problem38
- Failure to Deliver Energy33
- Suction Failure31
- Pressure Problem28
- Failure to Fire25
- Unexpected Shutdown23
Patient problems
- No Clinical Signs, Symptoms or Conditions277
- Insufficient Information189
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available14
- Intraocular Pressure Decreased13
- Endophthalmitis9
- Blurred Vision6
- Conjunctivitis6
- Iritis6
Recent adverse event reports
The 25 most recent of 498 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 22, 2026Failure to Cut
A healthcare professional reported that the cutter was not functioning on the ophthalmic system before surgery. The surgery was completed on the same day using an alternative system.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50851427 ↗MalfunctionSep 5, 2026Output Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50629153 ↗MalfunctionSep 4, 2026Pressure Problem
A customer reported that during surgery, an ophthalmic system had intraocular pressure problem. The surgery was completed on the same day with another cassette. The procedure type was not reported. No patient impact was reported. Additional information has been requested, but none received till date. This complaint pertains to ophthalmic system involved in the reported events.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50608101 ↗MalfunctionAug 27, 2026Failure to Cut
A customer reported that during vitrectomy surgery console vitrectomy blade was not moving. Procedure was completed on the same day without any patient harm.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50468323 ↗MalfunctionAug 26, 2026Failure to Cut
Patient problems: Insufficient Information
MAUDE report 50454335 ↗MalfunctionAug 25, 2026Output Problem
A customer reported that, prior to cataract surgery with intraocular lens implantation, the primary light source of an ophthalmic system failed. The surgery was completed on the same day using a secondary illumination module, and no patient harm was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50431129 ↗MalfunctionAug 21, 2026Failure to Fire
Patient problems: Insufficient Information
MAUDE report 50373399 ↗MalfunctionAug 21, 2026Gas Output Problem
A customer reported that the gas in an ophthalmic system would not fill and there was no patient contact. Procedure details have not been provided. Additional information was requested but was not available at the time of this report.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50371280 ↗MalfunctionAug 21, 2026Failure to Cut
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50370974 ↗MalfunctionAug 7, 2026Output Problem
Patient problems: Insufficient Information
MAUDE report 50176001 ↗MalfunctionAug 7, 2026Suction Failure
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50175536 ↗MalfunctionAug 7, 2026Suction Failure
Patient problems: Insufficient Information
MAUDE report 50170695 ↗MalfunctionAug 6, 2026Unexpected Shutdown
Patient problems: Insufficient Information
MAUDE report 50158482 ↗MalfunctionAug 6, 2026Failure to Fire
Patient problems: Insufficient Information
MAUDE report 50156851 ↗MalfunctionAug 4, 2026Unexpected Shutdown
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50127185 ↗MalfunctionJul 30, 2026Suction Failure
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50082950 ↗MalfunctionJul 29, 2026No Device Output
A physician reported that, during surgery ultrasound of an ophthalmic operating system did not oscillate. The surgery was completed on the same day using a replacement device. Procedure details and patient impact have not been reported.
Patient problems: Insufficient Information
MAUDE report 50066563 ↗MalfunctionJun 17, 2026Failure to Cut; Suction Failure
A CUSTOMER REPORTED THAT THE OPHTHALMIC SYSTEM HAD AN ISSUE WITH THE VITRECTOMY FUNCTION, WHICH WAS NOT ASPIRATING OR CUTTING. PROCEDURE DETAILS AND PATIENT IMPACT HAVE NOT BEEN PROVIDED.
Patient problems: Insufficient Information
MAUDE report 25532729 ↗MalfunctionMay 7, 2026Failure to Cut
A CUSTOMER REPORTED THAT THE OPHTHALMIC CONSOLE EXPERIENCED A PROBLEM WITH NONEXISTENT VITRECTOMY CUTTING DURING VITRECTOMY SURGERY. THE SURGERY WAS COMPLETED SUCCESSFULLY WITHOUT ANY IMPACT ON THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25111278 ↗MalfunctionApr 30, 2026Failure to Cut
A PHYSICIAN REPORTED THAT DURING SURGERY, AN OPHTHALMIC SYSTEM HAD NO CUTTING. THE SURGERY WAS COMPLETED WITH ALTERNATIVE SYSTEM WITHOUT ANY PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25040590 ↗MalfunctionApr 28, 2026Output Problem
A CUSTOMER REPORTED THAT THE OPHTHALMIC SYSTEM LAMP IN THE UPPER ILLUMINATION MODULE WAS NOT FUNCTIONING. PROCEDURE DETAILS AND PATIENT IMPACT WERE NOT PROVIDED.
Patient problems: Insufficient Information
MAUDE report 25013647 ↗MalfunctionApr 24, 2026Failure to Fire
A CUSTOMER REPORTED THAT LASER WAS NOT WORKING IN THE OPHTHALMIC SYSTEM. PROCEDURE DETAILS AND PATIENT IMPACT HAVE NOT BEEN PROVIDED. ADDITIONAL INFORMATION HAS BEEN REQUESTED BUT IS NOT AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Insufficient Information
MAUDE report 24985365 ↗MalfunctionApr 22, 2026Output Problem
THE CUSTOMER REPORTED THAT DURING PARS PLANA VITRECTOMY (PPV) SURGERY, AN OPHTHALMIC SYSTEM HAD LOW ILLUMINATION WITH BOTH THE PORTS. THE SURGERY WAS COMPLETED WITH ALTERNATIVE PRODUCT WITHOUT ANY PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24949200 ↗MalfunctionApr 8, 2026Suction Problem
A PHYSICIAN REPORTED THAT, DURING PHACOEMULSIFICATION (PHACO) MODE OF CATARACT SURGERY WITH INTRAOCULAR IMPLANTATION (IOL), AN OPHTHALMIC OPERATING SYSTEM PROVIDED LOW ASPIRATION. THE SURGERY WAS COMPLETED ON THE SAME DAY USING ANOTHER MACHINE WITHOUT ANY PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24814452 ↗MalfunctionApr 8, 2026Unexpected Shutdown
THE CUSTOMER REPORTED THAT DURING SURGERY, AN OPHTHALMIC SYSTEM SHUT DOWN IN THE MIDDLE OF THE SURGERY. DETAILS OF PROCEDURE AND PATIENT IMPACT WAS NOT PROVIDED.
Patient problems: Insufficient Information
MAUDE report 24813997 ↗
FDA clearance and classification
The FDA regulates product code HQE (instrument, vitreous aspiration and cutting, ac-powered) under 21 CFR 886.4150 as a Class II device. 21 CFR 886.4150 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CONSTELLATION 8065753041
Has the CONSTELLATION 8065753041 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00380657530410), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CONSTELLATION 8065753041?
The FDA's MAUDE database lists 498 adverse event reports for this device, received between Mar 26, 2021 and Sep 22, 2026. In those reports, the most common specific device problems are “Failure to Cut” (99), “Energy Output Problem” (38) and “Failure to Deliver Energy” (33); the most common patient problems are “Intraocular Pressure Decreased” (13), “Endophthalmitis” (9) and “Blurred Vision” (6). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CONSTELLATION 8065753041?
None of the reports are classified as deaths, 35 as injuries and 463 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the CONSTELLATION 8065753041, and is it still sold?
The FDA's device database lists Alcon Laboratories, Inc. as the company responsible for it (brand CONSTELLATION, model 8065753041). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Instrument, vitreous aspiration and cutting, ac-powered devices
- CONSTELLATION 8065751150Alcon Laboratories, Inc. · Instrument, vitreous aspiration and cutting, ac-powered1 recall1,238 reports
- Centurion, OZil 8065751761Alcon Laboratories, Inc. · Instrument, vitreous aspiration and cutting, ac-powered471 reports
- Ozil 8065750469Alcon Laboratories, Inc. · Instrument, vitreous aspiration and cutting, ac-powered260 reports
- UNITY 00380650002969Alcon Laboratories, Inc. · Instrument, Vitreous Aspiration And Cutting, Ac-Powered249 reports
- Infiniti 8065752160Alcon Laboratories, Inc. · Instrument, vitreous aspiration and cutting, ac-powered54 reports
- Bausch + Lomb SE5523WVBausch & Lomb Incorporated · Instrument, Vitreous Aspiration And Cutting, Ac-Powered1 recall4 reports
- Bausch + Lomb SE5525WVBausch & Lomb Incorporated · Instrument, Vitreous Aspiration And Cutting, Ac-Powered1 recall2 reports
- ALCON 00380650003935Alcon Laboratories, Inc. · Instrument, Vitreous Aspiration And Cutting, Ac-Powered1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page