Bausch + Lomb SE5523WVRecalls & reported problems

Bausch & Lomb Incorporated · 23 ga Combined Wide-Field Elite Pack · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
1

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 20757770059694), received between Apr 10, 2023 and Jul 10, 2024 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Dull, Blunt” (2 reports).

1 FDA recall record name this device's identifier.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Aug 8, 2018Terminated

    The back cap separates from the body of the vitrectomy cutter.

    Z-3275-2018 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗

Most reported problems

Device problems

  • Dull, Blunt2
  • Leak/Splash1
  • Particulates1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Retinal Detachment2

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 10, 2024Particulates; Particulates

    IT WAS REPORTED THAT THE SURGEON REMOVED A PARTICLE FROM THE EYE DURING A PROCEDURE. THE PARTICLE WAS NOTICED COMING DOWN THE IRRIGATION SIDE AND OUT THE IRRIGATION HOLE ON THE LEFT WHILE USING A QUAD TECHNIQUE FOR PHACOEMULSIFICATION. THE SURGEON HALTED THE PROCEDURE, REMOVED THE PHACOEMULSIFICATION TOOL, AND EXTRACTED THE PARTICLE WITH FORCEPS. NO HARM TO THE PATIENT WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19715578 ↗
  • InjuryApr 11, 2024Leak/Splash; Leak/Splash

    THE USER FACILITY IN THE UNITED KINGDOM REPORTED THAT DURING RETINAL DETACHMENT SURGERY, THREE TROCARS WERE LEAKING. THE PRESSURE WAS SET AT 30MMHG. SUTURES WERE REQUIRED AS THE WOUNDS DID NOT SEAL PROPERLY AT THE TROCAR ENTRY SIGHT. THE PROCEDURE WAS EXTENDED BY 15-20 MINUTES. THERE WAS NO FURTHER MEDICAL INTERVENTION NOR IMPACT OR CLINICAL CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19093113 ↗
  • InjuryApr 10, 2023Dull, Blunt; Dull, Blunt

    THE USER FACILITY IN FRANCE REPORTED THE INSTRUMENTS WERE NOT SHARP ENOUGH TO INSERT COMPLETELY. REPORTEDLY, THIS LED TO CHOROIDAL DETACHMENT INTRAOPERATIVELY. ANOTHER SATELLITE KIT (WITH SCLEROTOME AND TROCAR) WAS USED. THE PROCEDURE WAS DELAYED BY ONE HOUR AND THE PATIENT REQUIRED SEVERAL ADDITIONAL SCLEROTOMIES. THIS REPORT IS FOR THE SECOND PATIENT.

    Patient problems: Retinal Detachment

    MAUDE report 16707510 ↗
  • InjuryApr 10, 2023Dull, Blunt; Dull, Blunt

    THE USER FACILITY IN FRANCE REPORTED THE INSTRUMENTS WERE NOT SHARP ENOUGH TO INSERT COMPLETELY. REPORTEDLY, THIS LED TO CHOROIDAL DETACHMENT INTRAOPERATIVELY. ANOTHER SATELLITE KIT (WITH SCLEROTOME AND TROCAR) WAS USED. THE PROCEDURE WAS DELAYED BY ONE HOUR AND THE PATIENT REQUIRED SEVERAL ADDITIONAL SCLEROTOMIES. THIS REPORT IS FOR THE FIRST PATIENT.

    Patient problems: Retinal Detachment

    MAUDE report 16707449 ↗

Other Instrument, Vitreous Aspiration And Cutting, Ac-Powered devices

All Instrument, Vitreous Aspiration And Cutting, Ac-Powered devices →