ARCHITECT 2P56-42Recalls & reported problems
Abbott GmbH · Lactate Dehydrogenase · Class 2
All models of ARCHITECT (48)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00380740161477), received between Feb 7, 2020 and Jun 11, 2020 — classified as 3 malfunctions.
The most frequently reported specific device problem is “High Test Results” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- High Test Results3
Patient problems
- No Consequences Or Impact To Patient2
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 11, 2020High Test Results; High Test Results
THE CUSTOMER STATED THAT A FALSELY ELEVATED ARCHITECT LDH RESULT OF 337 U/L WAS GENERATED FOR A PATIENT SAMPLE THAT RETESTED AT 151 U/L ON THE SAME ARCHITECT ANALYZER AND 132/136 U/L ON A DIFFERENT ARCHITECT ANALYZER. THE CUSTOMER'S NORMAL RANGE IS 125 TO 220 U/L. NO ADVERSE IMPACT TO PATIENT MANAGEMENT WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10146006 ↗MalfunctionFeb 25, 2020High Test Results; High Test Results
THE CUSTOMER STATED THAT A FALSELY ELEVATED ARCHITECT LDH RESULT OF 337 U/L WAS GENERATED FOR A PATIENT SAMPLE THAT RETESTED AT 151 U/L ON THE SAME ARCHITECT ANALYZER AND 132/136 U/L ON A DIFFERENT ARCHITECT ANALYZER. THE CUSTOMER'S NORMAL RANGE IS 125 TO 220 U/L. NO ADVERSE IMPACT TO PATIENT MANAGEMENT WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9752912 ↗MalfunctionFeb 7, 2020High Test Results; High Test Results
THE CUSTOMER REPORTED A FALSE ELEVATED LACTATE DEHYDROGENASE (LDH) RESULT WHEN PROCESSING ON THE ARCHITECT C16000. THE INITIAL RESULT WAS 514 U/L AND RETEST WAS 198 U/L. RETESTING ON ANOTHER INSTRUMENT YIELDED RESULTS OF 195, 7, AND 197 U/L. THE CUSTOMER USES A REFERENCE RANGE OF 125-220 U/L. NO IMPACT TO PATIENT MANAGEMENT WAS REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9682538 ↗
FDA clearance and classification
The FDA regulates product code CFJ (nad reduction/nadh oxidation, lactate dehydrogenase) under 21 CFR 862.1440 as a Class II device. 21 CFR 862.1440 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the ARCHITECT 2P56-42
Has the ARCHITECT 2P56-42 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00380740161477), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the ARCHITECT 2P56-42?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Feb 7, 2020 and Jun 11, 2020. In those reports, the most common specific device problem is “High Test Results” (3). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the ARCHITECT 2P56-42?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the ARCHITECT 2P56-42 FDA approved?
Devices of this type (product code CFJ) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Abbott GmbH.
Who makes the ARCHITECT 2P56-42, and is it still sold?
The FDA's device database lists Abbott GmbH as the company responsible for it (brand ARCHITECT, model 2P56-42). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE devices
- ARCHITECT 2P56-21Abbott Laboratories · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE51 reports
- LDH P-L LD3818Randox Laboratories Limited · Nad Reduction/Nadh Oxidation, Lactate Dehydrogenase1 recall0 reports
- LDH L-P LD3842Randox Laboratories Limited · Nad Reduction/Nadh Oxidation, Lactate Dehydrogenase1 recall0 reports
- Lactate Dehydrogenase acc. to IFCC ver.2 08057958190Roche Diagnostics GmbH · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE15 reports
- ARCHITECT 2P56-22Abbott GmbH · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE13 reports
- Lactate Dehydrogenase acc to IFCC ver2 3004732122Roche Diagnostics GmbH · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE7 reports
- Alinity 07P7420Abbott GmbH · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE6 reports
- Lactate Dehydrogenase acc. to IFCC ver.2 5401674190Roche Diagnostics GmbH · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE2 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page