Lactate Dehydrogenase acc to IFCC ver2 3004732122Recalls & reported problems
Roche Diagnostics GmbH · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 04015630916276), received between Mar 13, 2023 and Dec 17, 2025 — classified as 7 malfunctions.
The most frequently reported specific device problem is “Non Reproducible Results” (5 reports).
2 other recalls cover devices cleared under the same FDA submission (K964457); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Non Reproducible Results5
- High Test Results2
- Incorrect, Inadequate or Imprecise Result or Readings2
- Incorrect Measurement1
- Insufficient Device Problem Information1
- Low Test Results1
Patient problems
- No Clinical Signs, Symptoms or Conditions7
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 17, 2025Non Reproducible Results; Non Reproducible Results
THE INITIAL REPORTER STATED THEY RECEIVED DISCREPANT RESULTS FOR ONE PATIENT SAMPLE TESTED WITH LACTATE DEHYDROGENASE ON A COBAS C 503 ANALYTICAL UNIT. THE SAMPLE INITIALLY RESULTED IN AN LDH VALUE OF 448 U/L. THE SAMPLE WAS REPEATED TWICE, RESULTING IN VALUES OF 237 U/L AND 239 U/L.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23830470 ↗MalfunctionNov 26, 2025Incorrect, Inadequate or Imprecise Result or Readings; High Test Results; Incorrect, Inadequate or Imprecise Result or Readings; High Test Results
THERE WAS AN ALLEGATION OF QUESTIONABLE LACTATE DEHYDROGENASE (LDH) RESULTS FOR 2 PATIENT SAMPLES ON A COBAS 8000 COBAS C 502 MODULE. THIS MEDWATCH WILL COVER LDH. REFER TO MEDWATCH WITH A1 PATIENT IDENTIFIER (B)(6) FOR INFORMATION ON THE ALP RESULTS, MEDWATCH WITH A1 PATIENT IDENTIFIER (B)(6) FOR INFORMATION ON THE CALCIUM RESULTS, MEDWATCH WITH A1 PATIENT IDENTIFIER (B)(6) FOR INFORMATION ON THE LACTATE RESULTS, AND MEDWATCH WITH A1 PATIENT IDENTIFIER (B)(6) FOR INFORMATION ON THE AST RESULTS. THE DOCTOR QUESTIONED THE RESULTS AS THEY WERE HIGH AND DID NOT MATCH THE CLINICAL STATUS OF OUTPATIENTS IN "NORMAL" CONDITION. NO SPECIFIC SAMPLE RESULTS WERE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23657157 ↗MalfunctionNov 14, 2025Incorrect Measurement; Low Test Results; Insufficient Device Problem Information; Non Reproducible Results; Incorrect Measurement; Low Test Results; Insufficient Device Problem Information; Non Reproducible Results
THERE WAS AN ALLEGATION OF QUESTIONABLE LACTATE DEHYDROGENASE RESULTS FOR 1 PATIENT SAMPLE ON A COBAS 8000 COBAS C 502 MODULE. THE INITIAL RESULT WAS 154 U/L. THE DOCTOR QUESTIONED THE RESULT WHICH PROMPTED THE CUSTOMER TO REPEAT THE SAMPLE. THE SAMPLE WAS REPEATED ON ANOTHER C502 ANALYZER AND THE RESULT WAS 310 U/L. THE REPEAT RESULT WAS DEEMED CORRECT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23556581 ↗MalfunctionSep 19, 2024Non Reproducible Results; Non Reproducible Results
THERE WAS AN ALLEGATION OF QUESTIONABLE LACTATE DEHYDROGENASE RESULTS FROM THE COBAS 6000 C501 MODULE. THE INITIAL RESULT WAS 629 U/L. THE REPEAT RESULTS WERE 884 U/L AND 427 U/L. THE INITIAL RESULT WAS BELIEVED TO BE CORRECT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20261177 ↗MalfunctionMar 26, 2024Incorrect, Inadequate or Imprecise Result or Readings; High Test Results; Incorrect, Inadequate or Imprecise Result or Readings; High Test Results
THERE WAS AN ALLEGATION OF QUESTIONABLE LACTATE DEHYDROGENATE (LDHI GEN.2) RESULTS FROM THE COBAS 6000 C 501 ANALYZER. THE CUSTOMER WAS SWITCHING TO A NEW LOT OF REAGENT AND PERFORMED A PATIENT COMPARISON. THE SAMPLES WERE REPEATED ON ANOTHER COBAS 6000 C 501 USING NEW REAGENT LOT 747707. THE CUSTOMER DID NOT KNOW WHICH RESULT WAS CORRECT. PATIENT 1 INITIAL RESULT WAS 377 U/L AND THE REPEAT RESULT WAS 245 U/L. PATIENT 2 INITIAL RESULT WAS 260 U/L AND THE REPEAT RESULT WAS 153 U/L. PATIENT 3 INITIAL RESULT WAS 390 U/L AND THE REPEAT RESULT WAS 245 U/L. PATIENT 4 INITIAL RESULT WAS 262 U/L AND THE REPEAT RESULT WAS 153 U/L.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18979865 ↗MalfunctionNov 20, 2023Non Reproducible Results; Non Reproducible Results
THERE WAS AN ALLEGATION OF QUESTIONABLE LDHI2 LACTATE DEHYDROGENASE ACC. TO IFCC VER.2 RESULTS FOR 2 PATIENT SAMPLES ON A COBAS 6000 C501 MODULE. THIS MEDWATCH WILL COVER LDHI2. REFER TO MEDWATCH WITH A1 PATIENT IDENTIFIER (B)(6) FOR INFORMATION ON THE ALP2 RESULTS. ON 23-OCT-2023, SAMPLE 1 HAD AN INITIAL LDH RESULT OF 375 U/L. TH SAMPLE WAS REPEATED TWICE AND THE RESULTS WERE 592 U/L AND 440 U/L. ON 25-OCT-2023, SAMPLE 2 HAD AN INITIAL LDH RESULT OF 598.0 U/L. THE REPEAT RESULT WAS 254.1 U/L.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18170481 ↗MalfunctionMar 13, 2023Non Reproducible Results; Non Reproducible Results
THE INITIAL REPORTER STATED THEY RECEIVED DISCREPANT RESULTS FOR ONE PATIENT SAMPLE TESTED WITH LDHI2 LACTATE DEHYDROGENASE ACC. TO IFCC VER.2 ON A COBAS INTEGRA 400 PLUS (SERIAL NUMBER (B)(4). NO QUESTIONABLE RESULTS WERE REPORTED OUTSIDE OF THE LABORATORY. THE CUSTOMER INITIALLY HAD ISSUES WITH AN UNSPECIFIED NUMBER OF PATIENT SAMPLES TESTED WITH LDH. THE RESULTS WOULD BE HIGH AND THEN REPEAT LOWER. THE PROBES WERE REPLACED AND PRECISION WAS CHECKED. A WASH STATION WAS ALSO INSPECTED. THE FIELD APPLICATION SPECIALIST UPDATED THE APPLICATION SETTINGS TO USE A DIFFERENT APPLICATION OF THE SAME REAGENT, BUT THE ISSUE STILL PERSISTED LEADING TO THE COMPLAINED SAMPLE RESULTS. THE SAMPLE INITIALLY RESULTED IN AN LDH VALUE OF 733 U/L. DUE TO ONGOING ISSUES OF THE SAME NATURE, THE SAMPLE WAS REPEATED TWICE, RESULTING IN VALUES OF 211 U/L AND 217 U/L.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16531778 ↗
FDA clearance and classification
Cleared through 510(k) K964457 on Jan 13, 1997 (decision: Substantially Equivalent). Submitted by Roche Diagnostic Systems, Inc. as “Roche Cobas Ibtegra Reagent Cassettes”. The FDA review took 68 days. FDA record ↗
The FDA regulates product code CFJ (nad reduction/nadh oxidation, lactate dehydrogenase) under 21 CFR 862.1440 as a Class II device. 21 CFR 862.1440 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K964457. One submission often covers many models, so check the product and lot details in each record.
- Z-1146-2019 · Dec 17, 2018 · TerminatedLactate Gen.2, Catalog Nos. 03183700190, 05171881190, 11822837190, ***added as of 5/10/19*** 03183700190 Product Usage: An In vitro diagnostic reagent system intended for use on
- Z-1926-2015 · May 7, 2015 · TerminatedLactate. Intended for use on COBAS INTEGRA 800 and 400 plus systems, cobas c111, Roche/Hitachi MODULAR systems, and cobas c systems for the quantitative determination of lactate c
Common questions about the Lactate Dehydrogenase acc to IFCC ver2 3004732122
Has the Lactate Dehydrogenase acc to IFCC ver2 3004732122 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04015630916276), based on the FDA recall file dated Nov 27, 2026. However, 2 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.
What problems have been reported with the Lactate Dehydrogenase acc to IFCC ver2 3004732122?
The FDA's MAUDE database lists 7 adverse event reports for this device, received between Mar 13, 2023 and Dec 17, 2025. In those reports, the most common specific device problems are “Non Reproducible Results” (5), “High Test Results” (2) and “Incorrect, Inadequate or Imprecise Result or Readings” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Lactate Dehydrogenase acc to IFCC ver2 3004732122?
None of the reports are classified as deaths, 0 as injuries and 7 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Lactate Dehydrogenase acc to IFCC ver2 3004732122 FDA approved?
It was cleared through 510(k) K964457 on Jan 13, 1997. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the Lactate Dehydrogenase acc to IFCC ver2 3004732122, and is it still sold?
The FDA's device database lists Roche Diagnostics GmbH as the company responsible for it (brand Lactate Dehydrogenase acc to IFCC ver2, model 3004732122). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE devices
- ARCHITECT 2P56-21Abbott Laboratories · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE51 reports
- LDH P-L LD3818Randox Laboratories Limited · Nad Reduction/Nadh Oxidation, Lactate Dehydrogenase1 recall0 reports
- LDH L-P LD3842Randox Laboratories Limited · Nad Reduction/Nadh Oxidation, Lactate Dehydrogenase1 recall0 reports
- Lactate Dehydrogenase acc. to IFCC ver.2 08057958190Roche Diagnostics GmbH · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE15 reports
- ARCHITECT 2P56-22Abbott GmbH · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE13 reports
- Alinity 07P7420Abbott GmbH · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE6 reports
- ARCHITECT 2P56-42Abbott GmbH · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE3 reports
- Lactate Dehydrogenase acc. to IFCC ver.2 5401674190Roche Diagnostics GmbH · NAD REDUCTION/NADH OXIDATION, LACTATE DEHYDROGENASE2 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page