BD Nokor 305201Recalls & reported problems
Becton, Dickinson And Company · NEEDLE FILTER NOKOR 18X1-1/2 TW · Class 1
All models of BD Nokor (5)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00382903052011), received between Jun 16, 2022 and Aug 28, 2024 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Defective Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Defective Component1
- Device Markings/Labelling Problem1
- Packaging Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Insufficient Information1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 28, 2024
A PHARMACY TECHNICIAN WORKING IN THE CLEAN ROOM BROUGHT A CONCERN TO ME THAT SHE DISCOVERED AFTER OPENING WHAT SHE THOUGHT WAS A BD PRECISIONGLIDE NEEDLE 18G X 1 1/2" TW PACKAGE AND ATTACHING THE NEEDLE TO A SYRINGE. SHE NOTICED A FILTER ATTACHED WHICH CAUSE HER TO TAKE A SECOND LOOK AT THE PACKAGING AND DISCOVER THE NEEDLE WAS ACTUALLY A BD NOKOR FILTER NEEDLE WITH 5 MICRON FILTER 18G X 1 1/2 TW. SHE LOOKED IN ALL AREAS OF THE PHARMACY WHERE NEEDLES ARE STORED AND FOUND SEVERAL AREAS IN WHICH THESE PRODUCTS WERE MIXED. THEY HAVE THE SAME SHADE OF PINK STRIP ACROSS THE BOTTOM OF THE PACKAGING, THE ONLY NOTICEABLE (ALBEIT BARELY) DIFFERENCE BETWEEN THE PACKAGES IS THE PRODUCT NAME. THE HUB OF THE NEEDLES ARE ALSO SIMILAR SHADES THAT MAY BE ABLE TO DISCERN WHEN NOT SIDE BY SIDE. WE REMOVED THESE FILTER NEEDLES FROM THE PHARMACY AND ALERTED OUR DISTRIBUTION DEPARTMENT. WE ARE CONCERNED THAT SINCE BOTH TYPES OF NEEDLES ARE STOCKED IN OUR CRASH TRAYS THAT THEY COULD BE EASILY SWAPPED FOR ONE ANOTHER IN A HIGH-RISK SITUATION. ISMP IS A FEDERALLY CERTIFIED PATIENT SAFETY ORGANIZATION AND AD FDA MEDWATCH PARTNER ISMP, 5200 BUTLER PIKE, PLYMOUTH MEETING, PA 19462 / PHONE:215-947-7797 / EMAI
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20098285 ↗MalfunctionMar 5, 2024Defective Component; Defective Component
MATERIAL#: 305201 LOT#: UNKNOWN IT WAS REPORTED BY THE CUSTOMER REPORTED LITTLE BITS OF GLASS GET INTO THE MEDICATION BEFORE IT IS DRAWN UP. FILTER NOT WORKING PROPERLY. VERBATIM: LITTLE BITS OF GLASS GET INTO THE MEDICATION BEFORE IT IS DRAWN UP. FILTER NOT WORKING PROPERLY.
Patient problems: Insufficient Information
MAUDE report 18837126 ↗MalfunctionSep 14, 2023Packaging Problem; Packaging Problem
IT WAS REPORTED THAT THE BD 18 G BD NOKOR¿ 5 MICRON FILTER NEEDLE EXPERIENCED SHIPPING BOX OR INSIDE UNITS ARE WET. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: CUSTOMER GOT IN A CASE FROM BD THAT HAS 4 CASES INSIDE: 2 CASES OF 303018, 1 CASE OF 381167, 1 CASE OF 305201. THE CASE OF 305201 IS WRAPPED IN PLASTIC, THE BOX IS SOAKED IN WHAT SMELLS LIKE VINEGAR. THE MAIN BOX ISN¿T A REPACK BOX AND IT¿S NOT WET.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17746732 ↗MalfunctionJun 16, 2022Device Markings/Labelling Problem; Device Markings/Labelling Problem
IT WAS REPORTED THAT 3 BD 18 G BD NOKOR¿ 5 MICRON FILTER NEEDLES EXPERIENCED DISCOLORED PACKAGING. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: WE RECEIVED THE BATCH WITH A DISCOLORATION OF THE STERILIZATION METHOD ON THE PRIMARY PACKAGING.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14714170 ↗
Other NEEDLE, ASPIRATION AND INJECTION, DISPOSABLE devices
- N/A 305211Becton, Dickinson And Company · NEEDLE, ASPIRATION AND INJECTION, DISPOSABLE425 reports
- N/A 305180Becton, Dickinson And Company · NEEDLE, ASPIRATION AND INJECTION, DISPOSABLE300 reports
- N/A 305200Becton, Dickinson And Company · NEEDLE, ASPIRATION AND INJECTION, DISPOSABLE99 reports
- PneumoDart TM-317TyTek Medical Inc. · Needle, Aspiration And Injection, Disposable1 recall1 report
- TPAK TM-303TyTek Medical Inc. · Needle, Aspiration And Injection, Disposable1 recall0 reports
- N/A 305181Becton, Dickinson And Company · NEEDLE, ASPIRATION AND INJECTION, DISPOSABLE32 reports
- SOL-M™ Blunt Fill Needle with 5 Micron Filter 110022Sol-Millennium Medical, Inc. · Needle, Aspiration And Injection, Disposable17 reports
- CONFIDENCE SPINAL CEMENT SYSTEM 283903611Medos International Sàrl · NEEDLE, ASPIRATION AND INJECTION, DISPOSABLE17 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page