BD Totalys™ MultiProcessor Consumables Kit 491453Recalls & reported problems
Becton, Dickinson And Company · Totalys MultiProcessor Consumables Kit · Class 3
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00382904914530), received between Dec 23, 2022 and Jun 29, 2023 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Device Markings/Labelling Problem” (4 reports).
11 other recalls cover devices cleared under the same FDA submission (P970018); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device Markings/Labelling Problem4
Patient problems
- No Clinical Signs, Symptoms or Conditions4
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 29, 2023Device Markings/Labelling Problem; Device Markings/Labelling Problem
IT WAS REPORTED THAT 14 BD TOTALYS¿ MULTIPROCESSOR CONSUMABLES KIT HAD MISSING OR BLANK LABELS BEFORE USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER, TRANSLATED FROM JAPANESE: ACCORDING TO THE CUSTOMER'S REPORT, 13 TUBES WITH BLANK LABELS AND ONE TUBE WITHOUT A LABEL WERE FOUND BEFORE USAGE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17225676 ↗MalfunctionJun 7, 2023Device Markings/Labelling Problem; Device Markings/Labelling Problem
IT WAS REPORTED THAT BD TOTALYS MULTIPROCESSOR CONSUMABLES KIT THERE WAS A CENTRIFUGE TUBE MISSING LABEL INFORMATION. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: ACCORDING TO THE CUSTOMER'S REPORT, THERE WAS A CENTRIFUGE TUBE WITHOUT THE LABEL BEFORE USAGE. THE LOT# OF THE KIT IS UNKNOWN AND THE LOT# OF THE CENTRIFUGE TUBE IS REPORTED TO BE 20U2221.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17083655 ↗MalfunctionMar 6, 2023Device Markings/Labelling Problem; Device Markings/Labelling Problem
IT WAS REPORTED THAT WHILE USING THE BD TOTALYS MULTIPROCESSOR CONSUMABLES KIT, 480 THAT THERE WERE MISSING LABELS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: THIS IS A REPORT ABOUT A LABELING ISSUE. ACCORDING TO THE CUSTOMER¿S INFORMATION, A CENTRIFUGE TUBE WITHOUT A LABEL WAS FOUND BEFORE USAGE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16493102 ↗MalfunctionDec 23, 2022Device Markings/Labelling Problem; Device Markings/Labelling Problem
IT WAS REPORTED THAT BD TOTALYS MULTIPROCESSOR CONSUMABLES KIT, 480 CENTRIFUGE TUBES WITH NO LABELS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: THERE WERE SEVERAL CENTRIFUGE TUBES WITH LABELS ON WHICH NO LETTERS WERE PRINTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16043491 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P970018. One submission often covers many models, so check the product and lot details in each record.
- Z-0877-2017 · Feb 12, 2016 · TerminatedBD SurePathTM Preservative Collection Vials, catalog numbers 490505, 490527, 491095, 491096, and 491097. SurePath Preservative Fluid is designed for use with the PrepStain System
- Z-1813-2012 · Mar 22, 2012 · TerminatedPrepStain Installation Kit (PreCoat), Catalog/Model # 490528
- Z-1811-2012 · Mar 22, 2012 · TerminatedPrepStain Syringing Pipettes 240 (Catalog #490517)
- Z-1812-2012 · Mar 22, 2012 · TerminatedPrepStain GYN 480 Disposable Test Kit with PreCoat Slides (Catalog #490523
- Z-1815-2012 · Mar 22, 2012 · TerminatedPrepStain GN 480 Disposable Kit Catalog/Model 490542 This is a complete kit, per the firm's explanation, that contains the PrepStain Syringing Pipettes 240, the product being recal
- Z-1814-2012 · Mar 22, 2012 · TerminatedManual Method 1: 480 Test Kit (PreCoat), Catalog/Model # 490529
- Z-2085-2012 · Dec 8, 2011 · TerminatedPrepStain Kit: 1.2 DiTi Cone. The PrepStain System is a liquid-based thin layer cell preparation process. The PrepStain System produces SurePath Slides that are intended for use i
- Z-2088-2012 · Dec 8, 2011 · TerminatedPrepStain PM Kit, T-AG (Catalog 490588); PrepStain PM Kit Europe (Catalog 490671); PrepStain Prep Only PM Kit, T-AG (Catalog 490954); PrepStain PM Kit XLP, T-US-II (Catalog 490424)
- Z-2086-2012 · Dec 8, 2011 · TerminatedPrepStain Upgrade Kit: 1.3.0.3/1.2 DiTi Cone. The PrepStain System is a liquid-based thin layer cell preparation process. The PrepStain System produces SurePath Slides that are in
- Z-2087-2012 · Dec 8, 2011 · TerminatedPrepStain Slide Processor. The PrepStain System is a liquid-based thin layer cell preparation process. The PrepStain System produces SurePath Slides that are intended for use in t
- Z-1090-2009 · Sep 26, 2008 · TerminatedBD PrepStain System, Model Number: 799-14000-00; Catalog Number: 05CR000021, 05CR00021R, 799-13000-00, 799-13000-00R, 799-14000-00 and 799-14000-00R; Catalog Number: 05CR000021, 05
Other Processor, cervical cytology slide, automated devices
- BD SurePath™ Collection Vial 491452Becton, Dickinson And Company · Processor, cervical cytology slide, automated82 reports
- BD Totalys SlidePrep 491346Becton, Dickinson And Company · Processor, Cervical Cytology Slide, Automated53 reports
- BD PrepStain Slide Processor 490100Becton, Dickinson And Company · Processor, Cervical Cytology Slide, Automated24 reports
- BD Totalys MultiProcessor 443327Becton, Dickinson And Company · Processor, Cervical Cytology Slide, Automated13 reports
- BD PrepStain Slide Processor 490407Becton, Dickinson And Company · Processor, Cervical Cytology Slide, Automated4 reports
- BD PrepStain Slide Processor 490410Tripath Imaging, Inc. · Processor, Cervical Cytology Slide, Automated2 reports
- BD SurePath™ Manual Method Kit 491266Becton, Dickinson And Company · Processor, Cervical Cytology Slide, Automated1 report
- BD SurePath™ Preservative Fluid 491337Becton, Dickinson And Company · Processor, Cervical Cytology Slide, Automated1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page