InnoSpire Essence 00 (REF 1099966)Recalls & reported problems

Respironics Respiratory Drug Delivery (Uk) Ltd · Innospire Essence with SSD 120V 60HZ (US), 6-pack · Class 2

All models of InnoSpire Essence (4)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 00383730001814), received between Jun 9, 2017 and Jan 31, 2024 — classified as 2 injuries, 9 malfunctions.

The most frequently reported specific device problem is “Fire” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fire3
  • Cut In Material2
  • Degraded2
  • Smoking2
  • Failure to Deliver1
  • Infusion or Flow Problem1
  • Insufficient Device Problem Information1
  • Maintenance Does Not Comply To Manufacturers Recommendations1

Patient problems

  • No Consequences Or Impact To Patient5
  • No Clinical Signs, Symptoms or Conditions4
  • Patient Problem/Medical Problem1
  • Respiratory Distress1

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 31, 2024Failure to Deliver; Failure to Deliver

    THE MANUFACTURER WAS CONTACTED IN REFERENCE TO AN INNOSPIRE ESSENCE DEVICE. THE REPORTER STATED THE LIQUID (MEDICATION) IN THE DEVICE WOULD NOT CONVERT TO MIST. THERE IS NO ALLEGATION OF SERIOUS OR PERMANENT HARM OR INJURY. NO MEDICAL INTERVENTION WAS REQUIRED BY THE PATIENT. THE MANUFACTURER'S INVESTIGATION IS ONGOING. A FOLLOW-UP REPORT WILL BE SUBMITTED WHEN THE MANUFACTURER'S INVESTIGATION IS COMPLETE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18620049 ↗
  • MalfunctionMar 16, 2021Material Split, Cut or Torn; Material Split, Cut or Torn

    THE MANUFACTURER RECEIVED THIS DEVICE FOR EVALUATION IN RESPONSE TO A USER'S REPORT OF "NO POWER". THERE WAS NO INITIAL REPORT OF EXPOSED WIRING. THE EXACT DAY OF THE REPORTED EVENT IS UNKNOWN. UPON RECEIPT OF THE DEVICE, THE MANUFACTURER NOTED THE AC CORD WAS STRETCHED OUT BY THE STRAIN RELIEF AT THE NEBULIZER, WITH EXPOSURE TO DAMAGED ELECTRICAL WIRES. THERE IS NO EVIDENCE OF THERMAL DAMAGE ON THE INNER WIRES. THE ROOT CAUSE OF THE EVENT WAS UNABLE TO BE DETERMINED; HOWEVER, IT IS LIKELY THE AC POWER CORD HAD BEEN EXPOSED TO FORCES BEYOND INTENDED DESIGN. THE INNOSPIRE ESSENCE IS INTENDED TO PROVIDE A SOURCE OF COMPRESSED AIR FOR MEDICAL PURPOSES. IT IS TO BE USED WITH A PNEUMATIC (JET) NEBULIZER TO PRODUCE AEROSOL PARTICLES OF MEDICATION FOR RESPIRATORY THERAPY FOR BOTH CHILDREN AND ADULTS. LABELING INCLUDED WITH THE DEVICE WARNS THE USER, "IT IS RECOMMENDED TO HAVE A BACKUP DEVICE (E.G. MDI OR BATTERY-OPERATED COMPRESSOR) FOR RESPIRATORY DELIVERY IN CASE A SITUATION ARISES WHEN YOUR NEBULIZER CANNOT BE USED (E.G. DURING A POWER OUTAGE OR IF YOUR COMPRESSOR BECOMES INOPERABLE FOR ANY REASON)." LABELING ALSO WARNS THE USER THAT THE POWER SUPPLY CORD CANNOT BE REPLACED BY THE USER

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11496536 ↗
  • MalfunctionJan 14, 2021Fire; Insufficient Device Problem Information; Insufficient Device Problem Information

    THE MANUFACTURER RECEIVED A REPORT OF A POSSIBLE THERMAL EVENT TO AN INNOSPIRE ESSENCE NEBULIZER. THE USER REPORTED HE WAS USING THE NEBULIZER AND THEN SHUT IT OFF. WHEN HE CAME BACK INTO THE ROOM, THE NEBULIZER ALLEGEDLY WAS ON FIRE. HE UNPLUGGED THE NEBULIZER AND THREW IT OUTSIDE. THERE WAS NO PATIENT HARM OR INJURY REPORTED. THE MANUFACTURE'S INVESTIGATION IS ON-GOING. UPON COMPLETION OF THE INVESTIGATION, A FOLLOW UP REPORT WILL BE FILED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11170193 ↗
  • MalfunctionNov 10, 2020Fire; Smoking

    THE MANUFACTURER RECEIVED A REPORT OF A POSSIBLE THERMAL EVENT TO AN INNOSPIRE ESSENCE NEBULIZER. THE DEVICE ALLEGEDLY STARTED SMOKING AND FLAMES WERE SEEN AT THE POWER CORD WHILE THE PATIENT WAS USING THE DEVICE. THE PATIENT UNPLUGGED THE DEVICE AND THE FLAMES WENT OUT. THERE WAS NO PATIENT HARM OR INJURY REPORTED. THE MANUFACTURER'S INVESTIGATION IS ON-GOING. UPON COMPLETION OF THE INVESTIGATION, A FOLLOW UP REPORT WILL BE FILED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10816081 ↗
  • MalfunctionJun 10, 2020Fire; Smoking; Fire; Smoking

    THE MANUFACTURER RECEIVED A REPORT OF A POSSIBLE THERMAL EVENT TO AN INNOSPIRE ESSENCE NEBULIZER. THE DEVICE ALLEGEDLY STARTED SMOKING AND FLAMES WERE SEEN WHILE THE PATIENT WAS USING THE DEVICE. THE PATIENT UNPLUGGED THE DEVICE AND THREW IT OUTSIDE. THERE WAS NO PATIENT HARM OR INJURY REPORTED. THE PATIENT DISCARDED THE DEVICE. THE SERIAL NUMBER AND LOT NUMBER ARE MISSING, THEREFORE THE DATE OF MANUFACTURE IS UNABLE TO BE DETERMINED. THE EXACT DATE OF THE REPORTED EVENT IS UNKNOWN. THE INNOSPIRE ESSENCE IS INTENDED TO PROVIDE A SOURCE OF COMPRESSED AIR FOR MEDICAL PURPOSES. IT IS TO BE USED WITH A PNEUMATIC (JET) NEBULIZER TO PRODUCE AEROSOL PARTICLES OF MEDICATION FOR RESPIRATORY THERAPY FOR BOTH CHILDREN AND ADULTS. THIS IS NOT A LIFE SUPPORT DEVICE. LABELING INCLUDED WITH THE DEVICE WARNS THE USER, "IT IS RECOMMENDED TO HAVE A BACKUP DEVICE (E.G. MDI OR BATTERY-OPERATED COMPRESSOR) FOR RESPIRATORY DELIVERY IN CASE A SITUATION ARISES WHEN YOUR NEBULIZER CANNOT BE USED (E.G. DURING A POWER OUTAGE OR IF YOUR COMPRESSOR BECOMES INOPERABLE FOR ANY REASON)." THE MANUFACTURER WILL CONTINUE TO MONITOR THE COMPLAINT RECORDS FOR SIMILAR REPORTED FAILURES. BASED ON THE AVAILABLE INFORMATI

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10138582 ↗
  • InjuryJan 24, 2018Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT THIS DEVICE WOULD TURN ON, BUT NOT GIVE MEDICATION. AS A RESULT, THE PATIENT ATTENDED EMERGENCY ROOM (ER) TO GET MEDICINE TREATMENT. HE RECEIVED 2 BREATHING TREATMENTS AND WAS GIVEN A SCRIPT FOR ORAL STERIODS. THE DEVICE HAS NOT BEEN RETURNED FOR EVALUATION SO WE ARE UNABLE TO CONFIRM ANY DEFECT. INTERNAL REFERENCE RA 307144548.

    Patient problems: Respiratory Distress

    MAUDE report 7214656 ↗
  • MalfunctionJul 12, 2017Cut In Material; Cut In Material

    IT WAS REPORTED THAT THE MAINS CORD OF THIS DEVICE WAS BROKEN. ON RECEIPT OF THE DEVICE FOR EVALUATION IT WAS OBSERVED THAT THE MAINS CORD WAS SEVERED LEADING TO EXPOSED WIRES. IT APPEARS AS THOUGH THE CORD WAS INTENTIONALLY CUT, AND THE CUSTOMER WAS APPROACHED WITH REGARD TO CONFIRMING THIS ASSERTION. THEY HAVE NOT PROVIDED ANY FURTHER INFORMATION REGARDING HOW THE DEVICE CAME TO BE IN THIS CONDITION. THE IFU FOR THIS DEVICE CONTAINS THE WARNING 'THE POWER SUPPLY CORD CANNOT BE REPLACED BY THE USER. IN CASE THE POWER SUPPLY CORD BECOMES DAMAGED, CONTACT PHILIPS RESPIRONICS CUSTOMER SERVICE FOR REPLACEMENT (THERE IS NO SERVICE OPTION)'. INTERNAL REFERENCE: (B)(4).

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6705121 ↗
  • MalfunctionJul 10, 2017Degraded; Degraded

    IT WAS REPORTED THAT THE CORD OF THIS DEVICE WAS CUT. ON RECEIPT OF THE DEVICE FOR EVALUATION IT WAS OBSERVED THAT THE MAINS CORD WAS SEVERELY DAMAGED, LEADING TO EXPOSED WIRES. IT APPEARS AS THOUGH THE MAINS CORD HAD BEEN SUBJECTED TO CONSIDERABLE EXTERNAL STRESS, AND THE CUSTOMER WAS APPROACHED WITH REGARD TO CONFIRMING THIS ASSERTION. THEY HAVE NOT PROVIDED ANY FURTHER INFORMATION REGARDING HOW THE DEVICE CAME TO BE IN THIS CONDITION. THE IFU FOR THIS DEVICE CONTAINS THE WARNING 'THE POWER SUPPLY CORD CANNOT BE REPLACED BY THE USER. IN CASE THE POWER SUPPLY CORD BECOMES DAMAGED, CONTACT PHILIPS RESPIRONICS CUSTOMER SERVICE FOR REPLACEMENT (THERE IS NO SERVICE OPTION)'. (B)(4).

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6696377 ↗
  • MalfunctionJul 10, 2017Cut In Material; Cut In Material

    IT WAS REPORTED THAT THIS DEVICE HAD A BROKEN CORD. ON RECEIPT OF THE DEVICE FOR EVALUATION IT WAS OBSERVED THAT THE MAINS CORD WAS SEVERED LEADING TO EXPOSED WIRES. IT APPEARS AS THOUGH THE CORD WAS INTENTIONALLY CUT, AND THE CUSTOMER WAS APPROACHED WITH REGARD TO CONFIRMING THIS ASSERTION. THEY HAVE NOT PROVIDED ANY FURTHER INFORMATION REGARDING HOW THE DEVICE CAME TO BE IN THIS CONDITION. THE IFU FOR THIS DEVICE CONTAINS THE WARNING 'THE POWER SUPPLY CORD CANNOT BE REPLACED BY THE USER. IN CASE THE POWER SUPPLY CORD BECOMES DAMAGED, CONTACT PHILIPS RESPIRONICS CUSTOMER SERVICE FOR REPLACEMENT (THERE IS NO SERVICE OPTION)'. INTERNAL REFERENCE: (B)(4).

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6696372 ↗
  • InjuryJul 7, 2017Maintenance Does Not Comply To Manufacturers Recommendations; Maintenance Does Not Comply To Manufacturers Recommendations

    IT WAS REPORTED BY THE CAREGIVER THAT THE FILTER OF THIS DEVICE WAS VERY DIRTY AS THE PATIENT HAD NEVER CHANGED IT, AND AS A RESULT THE PATIENT WAS HOSPITALISED WITH WHAT THE CAREGIVER DESCRIBED AS 'BACTERIA BUILDUP'. IT ALSO SUBSEQUENTLY TRANSPIRED THAT THE NEBULISER CUPS AND MASKS HAD NOT BEEN BEING CLEANED REGULARLY - BUT REPLACED MONTHLY INSTEAD. THE IFU FOR THE COMPRESSOR STATES 'THE FILTER IS TO BE REPLACED WHEN IT APPEARS DISCOLORED OR WET' AND THE IFU FOR THE NEBULISER STATES 'AFTER EACH USE, DISCONNECT TUBING FROM SIDESTREAM AND WASH ALL PARTS SEPARATELY IN MILD LIQUID DETERGENT AND WARM WATER. RINSE THOROUGHLY AND SHAKE OUT EXCESS WATER. ALLOW TO AIR DRY AND REASSEMBLE.' REPLACEMENT FILTERS WERE PROVIDED, AND THE CLEANING REQUIREMENTS EXPLAINED TO THE CAREGIVER. THE PATIENT HAS RETAINED THE DEVICE, AND NO FURTHER ISSUES HAVE BEEN REPORTED WITH IT. (B)(4).

    Patient problems: Patient Problem/Medical Problem

    MAUDE report 6692811 ↗
  • MalfunctionJun 9, 2017Degraded; Degraded

    IT WAS REPORTED THAT THE POWER CORD OF THIS DEVICE WAS RIPPING AND FALLING APART. ON RETURN OF THE DEVICE FOR EVALUATION, IT WAS APPARENT THAT THE INSULATION ON THE MAINS CORD WAS DEGRADED TO THE EXTENT THAT BARE WIRES WERE VISIBLE. OUR EVALUATION CONCLUDED THAT IN ALL LIKELIHOOD THE CORD HAS BEEN SUBJECTED TO CONSIDERABLE EXTERNAL FORCE. (B)(4).

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6629122 ↗

Other Compressor, air, portable devices

All Compressor, air, portable devices →