Skip to content

Hemashield M002020952070Recalls & reported problems

Intervascular Sas · Hemashield Gold Knitted Microvel Straight Double Velour Vascular Graft with Graft Sizer Accessory · Class 2 · Implant

All models of Hemashield (51)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
0
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

No MAUDE adverse event reports in our data reference this device identifier directly.

1 FDA recall record name this device's identifier.

5 other recalls cover devices cleared under the same FDA submission (K954848); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Jan 14, 2022Class IITerminated

    Outer labelling (HEMASHIELD GOLD Knitted Microvel Double Velour Bifurcated Vascular Graft, D: 16 x 8 mm; L: 40 cm) does not correspond to the (inner) sterile packaging labelling (HEMASHIELD GOLD Knitted Microvel Double Velour Straight Vascular Graft, D: 7 mm L: 60 cm). Mislabeled product could cause a disruption of the vascular anastomosis in the long term, creating a pseudo-aneurysm

    Z-0729-2022 · Root cause: Packaging process control · Recall details · FDA record ↗

FDA clearance and classification

Cleared through 510(k) K954848 on Feb 1, 1996 (decision: Substantially Equivalent - Subject to Tracking Reg.). Submitted by Meadox Medicals, Div. Boston Scientific Corp. as “Hemashield Microvel Velour Knitted Vascular Graft”. The FDA review took 101 days. FDA record ↗

The FDA regulates product code MAL (graft, vascular, synthetic/biologic composite) under 21 CFR 870.3450 as a Class II device. 21 CFR 870.3450 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K954848. One submission often covers many models, so check the product and lot details in each record.

  • Z-0403-2022 · Dec 1, 2021 · Terminated
    Hemashield Gold Knitted Bifurcated, 18 mm x 9 mm; reference number M002020851890
  • Z-1860-2020 · Apr 7, 2020 · Terminated
    Hemashield Gold Knitted Microvel Double Velour Vascular Graft-Axillo-bifemoral, Product Code: M002020955880 - Product Usage: for use in the replacement or repair of arteries affect
  • Z-1861-2020 · Apr 7, 2020 · Terminated
    Hemashield Gold Knitted Microvel Double Velour Vascular Graft Axillo-bifemoral, Product Code: M002020955890 - Product Usage: for use in the replacement or repair of arteries affect
  • Z-1859-2020 · Apr 7, 2020 · Terminated
    Hemashield Gold Knitted Microvel Double Velour Vascular Graft-Axillo-bifemoral, Product Code: M002020955010 - Product Usage: For use in the replacement or repair of arteries affect
  • Z-2066-2010 · May 24, 2010 · Terminated
    Hemashield Gold Woven and Knitted Double Vascular Grafts.

Common questions about the Hemashield M002020952070

Has the Hemashield M002020952070 been recalled?

Yes. 1 FDA recall record names this device's identifier, and the FDA has closed (terminated) it. The recall, Z-0729-2022 (Class II), began on Jan 14, 2022: Outer labelling (HEMASHIELD GOLD Knitted Microvel Double Velour Bifurcated Vascular Graft, D: 16 x 8 mm; L: 40 cm) does not correspond to the (inner) sterile packaging labelling (HEMASHIELD GOLD Knitted Microvel… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

Is the Hemashield M002020952070 FDA approved?

It was cleared through 510(k) K954848 on Feb 1, 1996. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the Hemashield M002020952070 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.

Who makes the Hemashield M002020952070, and is it still sold?

The FDA's device database lists Intervascular Sas as the company responsible for it (brand Hemashield, model M002020952070). Its record shows it as in commercial distribution.