Skip to content

HemashieldRecalls & reported problems across all models

Intervascular Sas · 51 models in the FDA device registry

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
149
Deaths reported
1
Injuries reported
61
Recalls
4

We found 51 models of Hemashield by Intervascular Sas in the FDA's device registry (GUDID). Together they are named in 149 adverse event reports in the FDA's MAUDE database, received between Apr 15, 2016 and Sep 28, 2026 — classified as 1 death, 61 injuries, 87 malfunctions.

The most frequently reported specific device problem is “Product Quality Problem” (40 reports).

4 FDA recall records name at least one of these models by its device identifier.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works

Reports received per month, all models

Nov 2023: 2 reportsDec 2023: 2 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 2 reportsJun 2024: 0 reportsJul 2024: 4 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 10 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 4 reportsMay 2025: 1 reportsJun 2025: 1 reportsJul 2025: 1 reportsAug 2025: 1 reportsSep 2025: 2 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 1 reportsMay 2026: 2 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports20242025202610
Last 36 months. The most recent month may be incomplete.

Hemashield recalls

FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.

  1. Jan 14, 2022Terminated

    Outer labelling (HEMASHIELD GOLD Knitted Microvel Double Velour Bifurcated Vascular Graft, D: 16 x 8 mm; L: 40 cm) does not correspond to the (inner) sterile packaging labelling (HEMASHIELD GOLD Knitted Microvel Double Velour Straight Vascular Graft, D: 7 mm L: 60 cm). Mislabeled product could cause a disruption of the vascular anastomosis in the long term, creating a pseudo-aneurysm

    Z-0729-2022 · Root cause: Packaging process control · Recall details · FDA record ↗

  2. Dec 1, 2021Terminated

    There is a probable mislabeling of product. A Hemashield Platinum Woven Double Velour Bifurcated Vasuclar Graft, SN 1259735369, 24 mm x 12 mm, REF Number M00202166241P0 is likely packaged inside of the carton instead of a Hemashield Gold Knitted Microvel Double Velour Bifurcated Vascular Graft; SN 1260004700; 18 mm x 9 mm; REF Number M002020851890 or a Hemashield Gold Knitted Microvel Double Velour Bifurcated Vascular Graft; SN 1259882880; 18 mm x 9 mm; Ref Number M002020851890.

    Z-0403-2022 · Root cause: Labeling Change Control · Recall details · FDA record ↗

  3. Aug 22, 2019Terminated

    Based on an internal incident report, Getinge/Intervascular SAS has identified that the one (1) HEMASHIELD GOLD Knitted Microvel Double Velour Vascular Bifurcated Graft product with the diameter size of 16 x 9 mm is likely incorrectly packed inside of the carton which was labeled to contain a HEMASHIELD PLATINUM Woven Double Velour Vascular Graft product with the diameter size of 16 x 8 mm ((REF: M00202166168P0, Lot: 18K31, SN: 1190443415, size 16 x 8 mm).

    Z-2559-2019 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

  4. Jan 3, 2018Terminated

    A probable mislabeling of the product: a different-sized product is referenced on the product packaging label (i.e. 2.5 cm (width) x 7.6 cm (length)) while the actual product inside the box is 2.5 cm (width) x 15 cm (length).

    Z-1172-2018 · Root cause: Labeling mix-ups · Recall details · FDA record ↗

Most reported Hemashield problems

Device problems

  • Product Quality Problem40
  • Manufacturing, Packaging or Shipping Problem22
  • Nonstandard Device16
  • Material Frayed13
  • Off-Label Use12
  • Adverse Event Without Identified Device or Use Problem10
  • Material Puncture/Hole9
  • Device Contaminated During Manufacture or Shipping7

Patient problems

  • No Clinical Signs, Symptoms or Conditions55
  • Hemorrhage/Blood Loss/Bleeding28
  • No Patient Involvement19
  • Blood Loss18
  • No Consequences Or Impact To Patient13
  • Fungal Infection4
  • Insufficient Information3
  • No Information3

Hemashield models

51 models, most reported first. Each model has its own page with its reports, recalls and device details.

Recent Hemashield adverse event reports

The 15 most recent reports across all models, in the reporter's own words as published by the FDA.

Other Intervascular Sas products

All Intervascular Sas devices →

Sources and updates