Skip to content

Unistik 3 AT1014Recalls & reported problems

Owen Mumford Limited · Unistik 3 Extra - 21G x 2.0mm - 200 count - sterile, single use safety lancet · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00384701014017), received between Oct 12, 2018 and Oct 11, 2024 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Retraction Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 2 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Retraction Problem2
  • Fail-Safe Did Not Operate1
  • Fail-Safe Problem1
  • Protective Measures Problem1

Patient problems

  • Needle Stick/Puncture2
  • No Clinical Signs, Symptoms or Conditions2
  • Anxiety1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 11, 2024Retraction Problem; Retraction Problem

    PCT WAS GIVING PATIENT BLOOD SUGAR CHECK AND WHEN GOING TO PUT THE LANCET IN THE SHARPS CONTAINER THE NEEDLE WOULD NOT RETRACT AND STUCK PCT'S FINGER. NURSE MANAGER PUT LANCET IN SPECIMEN CONTAINER AND THE NEEDLE DID EVENTUALLY RETRACT WITH SOME MOVEMENT. IT APPEARS THERE WAS AN ISSUE WITH THE SAFETY MECHANISM. THE PCT CLEANED THE SITE AND DID NOT NEED CARE.

    Patient problems: Needle Stick/Puncture; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20431112 ↗
  • MalfunctionOct 11, 2024Retraction Problem; Retraction Problem

    PCT WAS GIVING PATIENT BLOOD SUGAR CHECK AND WHEN GOING TO PUT THE LANCET IN THE SHARPS CONTAINER THE NEEDLE WOULD NOT RETRACT AND STUCK PCT'S FINGER. NURSE MANAGER PUT LANCET IN SPECIMEN CONTAINER AND THE NEEDLE DID EVENTUALLY RETRACT WITH SOME MOVEMENT. IT APPEARS THERE WAS AN ISSUE WITH THE SAFETY MECHANISM. THE PCT CLEANED THE SITE AND DID NOT NEED CARE.

    Patient problems: Needle Stick/Puncture; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20431020 ↗
  • MalfunctionOct 12, 2018Fail-Safe Problem; Protective Measures Problem; Fail-Safe Did Not Operate; Fail-Safe Problem; Protective Measures Problem; Fail-Safe Did Not Operate

    HEAD NURSE OF (B)(6) STATED ANOTHER NURSE REPORTED TO HER THAT SHE WAS ALMOST STUCK WITH AN EXPOSED LANCET BECAUSE IT DID NOT RETRACT AFTER TESTING A PATIENT.

    Patient problems: Anxiety

    MAUDE report 7963167 ↗

Other Lancet, Blood devices

All Lancet, Blood devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page