- Adverse event reports
- 16
- Deaths reported
- 0
- Injuries reported
- 12
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 00606509100212), received between Apr 26, 2019 and Oct 13, 2023 — classified as 12 injuries, 4 malfunctions.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Appropriate Device Problem Term/Code Not Available16
Patient problems
- Bruise/Contusion4
- Bone Fracture(s)3
- No Clinical Signs, Symptoms or Conditions3
- Head Injury2
- Concussion1
- Injury1
- No Known Impact Or Consequence To Patient1
- Patient Problem/Medical Problem1
Recent adverse event reports
The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 13, 2023Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
CONSUMER ALLEGES HE SMELLED SMOKE AND WENT TO CHECK HIS CHAIR THAT WAS CHARGING. HE ALLEGES THE BATTERY CHARGER LIGHT WAS GREEN, SO HE UNPLUGGED THE CHARGER CORD FROM THE CHAIR, HE ALLEGEDLY HEARD A FAINT CLICKING SOUND ALLEGEDLY COMING FROM UNDER THE CHAIR. WHEN HE LOOKED AT THE CHAIR, HE ALLEGES SMOKE STARTED TO BILLOW OUT, THE BATTERY ALLEGEDLY STARTED HISSING AND FLAMES ALLEGEDLY BEGAN TO SHOOT OUT TO ABOUT 4-6 INCHES IN AT LEAST TWO DIRECTIONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17930516 ↗InjurySep 13, 2023Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
CONSUMER ALLEGES GOING UP HER RAMP THE CHAIR ALLEGEDLY TIPPED BACKWARDS WITH THE CONSUMER IN THE CHAIR. CUSTOMER IS USING THE UNIT ON A NON-ADA APPROVED RAMP CAUSING THE ISSUE.
Patient problems: Bruise/Contusion
MAUDE report 17737540 ↗InjurySep 8, 2023Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
CONSUMER WAS EXITING AN ELEVATOR WHEN THE JAZZY FRONT WHEELS ALLEGEDLY DROPPED DOWN INTO THE ELEVATOR OPENING ALLEGEDLY CAUSING THE FOOT PLATFORM TO RISE AND ALLEGEDLY CRUSH HER LEFT LOWER LEG.
Patient problems: Bone Fracture(s)
MAUDE report 17710140 ↗MalfunctionMar 17, 2022Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
RECEIVED NOTICE OF A FIRE THAT OCCURRED WHERE A JAZZY PASSPORT WAS PRESENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13801335 ↗InjuryJan 18, 2022Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
PROVIDER ALLEGES CONSUMER HAS FALLEN OVER IN THE CHAIR A FEW TIMES RESULTING IN THE ARM BREAKING ON THE CHAIR.
Patient problems: Bruise/Contusion
MAUDE report 13281757 ↗InjurySep 22, 2021Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
PROVIDER ALLEGES THE CONSUMER'S WIFE ALLEGES THE CHAIR ALLEGEDLY FOLDED WHILE THE CONSUMER WAS DRIVING AND ALLEGEDLY THREW THE CONSUMER OUT.
Patient problems: Bruise/Contusion
MAUDE report 12512655 ↗MalfunctionSep 22, 2021Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
PROVIDER ALLEGES CONSUMER TIPPED OVER BACKWARDS ON A DRIVEWAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12512643 ↗InjuryMay 21, 2021Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
PROVIDER ALLEGES CONSUMER FLIPPED BACKWARDS TWICE WHILE ON CHAIR.
Patient problems: Concussion
MAUDE report 11863073 ↗InjuryMay 3, 2021Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ALLEGES FLIPPING DEVICE BACKWARDS ON TWO DIFFERENT OCCASIONS. ALLEGES NOT OPERATING ON A STEEP RAMP OR ANYTHING OUT OF THE ORDINARY.
Patient problems: Head Injury
MAUDE report 11760892 ↗InjuryApr 28, 2020Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
CONSUMER ALLEGES WHILE GOING DOWN AND UP A SIDEWALK CUT OUT HER LEG ALLEGEDLY FELL OFF OF THE FOOT PLATE. HER CHAIR ALLEGEDLY CONTINUED TO MOVE FORWARD, HER LEG BENT BACKWARDS UNDER THE WHEEL AND GOT STUCK.
Patient problems: Bone Fracture(s)
MAUDE report 10004688 ↗InjuryJan 20, 2020Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
CONSUMER'S MOTHER ALLEGES WHILE TRAVELING IN MEXICO THE UNIT ALLEGEDLY TIPPED BACKWARDS CAUSING THE CONSUMER TO HIT HIS HEAD.
Patient problems: Head Injury
MAUDE report 9607188 ↗MalfunctionJan 15, 2020Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ALLEGES FRONT CASTER FELL OFF. CALLED AMBULANCE TO GET BACK IN BED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9590315 ↗InjuryDec 10, 2019Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
PROVIDER ALLEGES CONSUMER TIPPED OVER BACKWARDS IN HIS UNIT. PROVIDER STATED THAT THE CONSUMER TOLD HER IT WAS HIS FAULT.
Patient problems: Bruise/Contusion
MAUDE report 9446016 ↗InjuryAug 9, 2019Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
CONSUMER ALLEGES AS SHE WAS LOADING HER CHAIR WHICH WAS FOLDED, INTO THE BACK OF HER VAN, WHEN SHE FELT A PINCH. WHEN SHE GOT INTO HER VEHICLE SHE ALLEGEDLY NOTICED HER FINGER WAS DISLOCATED.
Patient problems: Bone Fracture(s)
MAUDE report 8880121 ↗InjuryMay 9, 2019Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
CONSUMER ALLEGES THAT HIS WIFE'S REAR TIRE ON HER UNIT GOT A FLAT. HIS WIFE TRIED TO DRIVE THE UNIT AND THE FRONT CASTER WHEEL BROKE. BECAUSE OF THE ALLEGED INCIDENT CONSUMER MISSED HER KIDNEY DIALYSIS AND ENDED UP IN THE HOSPITAL.
Patient problems: Patient Problem/Medical Problem
MAUDE report 8596405 ↗InjuryApr 26, 2019Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
CONSUMER ALLEGES HER FATHER'S LEG GOT TRAPPED AND INJURED WHILE MOVING INSIDE HIS CHAIR.
Patient problems: Injury
MAUDE report 8557238 ↗
FDA clearance and classification
The FDA regulates product code ITI (wheelchair, powered) under 21 CFR 890.3860 as a Class II device. 21 CFR 890.3860 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
FDA definition of this device type: A powered wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position. FDA interprets mobility to persons restricted to a sitting position to mean the device type is intended to provide mobility to individuals who have mobility impairments and require an assistive device for mobility. NOTE: This type of device is not intended to climb stairs (see product code: IMK).
Common questions about the Jazzy Passport
Has the Jazzy Passport been recalled?
No FDA recall record in our data names this exact device identifier (DI 00606509100212), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Jazzy Passport?
The FDA's MAUDE database lists 16 adverse event reports for this device, received between Apr 26, 2019 and Oct 13, 2023. In those reports, the most common patient problems are “Bruise/Contusion” (4), “Bone Fracture(s)” (3) and “Head Injury” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Jazzy Passport?
None of the reports are classified as deaths, 12 as injuries and 4 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Jazzy Passport, and is it still sold?
The FDA's device database lists Pride Mobility Products Corp as the company responsible for it (brand Jazzy Passport, model Jazzy Passport). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Wheelchair, Powered devices
- SmartDrive® MX2+Max Mobility, LLC · Wheelchair, Powered858 reports
- Permobil M3Permobil, Inc. · Wheelchair, Powered1 recall60 reports
- TDX SP2 Base for Multiple Actuator System w/ Ultra Low Maxx TDXSP2-MCGInvacare Corporation · Wheelchair, powered2 recalls2 reports
- TDX SP2 with LiNX Electronics TDXSP2Invacare Corporation · Wheelchair, powered2 recalls0 reports
- Invacare® TDX SP2 with Captain's Seat TDXSP2VInvacare Corporation · Wheelchair, powered2 recalls0 reports
- Q6 Edge 3Pride Mobility Products Corp · Wheelchair, Powered4 deaths87 reports
- Q6 Edge 2.0 Q6 Edge 2.0 / Q6 Edge 2.0 with iLevelPride Mobility Products Corp · Wheelchair, Powered1 death83 reports
- Permobil M5Permobil, Inc. · Wheelchair, Powered1 recall7 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page