Q6 Edge Q6 Edge/Q4/J623/Q623/Q6 Edge RQ/Q6 Edge XRecalls & reported problems
Pride Mobility Products Corp · A powered wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position. · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 8
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00606509200028), received between Jan 23, 2018 and Jul 19, 2021 — classified as 8 injuries, 1 malfunction.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Appropriate Device Problem Term/Code Not Available9
Patient problems
- Bone Fracture(s)2
- Bruise/Contusion2
- Eye Injury2
- Head Injury2
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Injury1
- Muscle/Tendon Damage1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
InjuryJul 19, 2021Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
CONSUMER ALLEGES WHILE GETTING OUT HIS CHAIR, THE ARMREST ALLEGEDLY BROKE ALLEGEDLY CAUSING HIM TO FALL FORWARD. TO PREVENT FROM FALLING FORWARD, CONSUMER TRIED TO GRAB THE OTHER ARMREST ALLEGEDLY CAUSING HIS RIGHT ARM TO TWIST.
Patient problems: Muscle/Tendon Damage
MAUDE report 12189557 ↗InjuryJul 6, 2021Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
THE DEALERS PROVIDED LOANER CHAIRS TO CONSUMER AND ON BOTH OCCASIONS SHE HAD AN ALLEGED INCIDENT WITH LOANER UNITS.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 12122829 ↗InjuryJun 8, 2020Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ALLEGES WHILE SETTING UP NEW HEAD ARRAY DEVICE FOR END USER, WITH END USER IN UNIT, THE UNIT WOULD NOT STOP, AND COULDN'T CONTROL THE PWC, AND IT BEGAN TO TIP FORWARDS AFTER ROLLING 10 FEET. ALLEGES THE CLIENT THEN FELL DOWN IN THE STAIRS (4 STEPS IN TOTAL) CAUSING INJURY.
Patient problems: Eye Injury; Head Injury; Pain
MAUDE report 10128393 ↗InjuryJan 27, 2020Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
CONSUMER CLAIMS HER WHEELS WERE ALLEGEDLY BINDING UP AND ONE OF THE TIMES IT HAPPENED IT ALLEGEDLY THREW HER OUT OF THE CHAIR.
Patient problems: Bone Fracture(s)
MAUDE report 9631291 ↗InjuryAug 9, 2019Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ALLEGES ARMRESTS BROKE DUE TO LEANING OR USING THEM FOR TRANSFER IN THE BATHROOM CAUSING HER TO FALL OUT OF THE CHAIR AND HIT HEAD ON SINK.
Patient problems: Eye Injury; Head Injury
MAUDE report 8880128 ↗InjuryAug 3, 2018Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ALLEGES ARM MOUNT BRACKET BOLT SNAPPED DURING TRANSFER. ARM SNAPPED OFF AND CONSUMER FELL TO GROUND, HITTING HEAD AND INJURING KNEE.
Patient problems: Bruise/Contusion; Injury
MAUDE report 7747517 ↗InjuryMay 11, 2018Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ALLEGES DRIVING ALONG IN LATCH MODE AND THE CHAIR STARTED VEERING TO THE RIGHT. ALLEGES HE COULD NOT STOP IT VEERING TO THE RIGHT AND HE SUCKED IN TO INITIATE THE STOP AND IT WOULD NOT STOP. ALLEGES CROSSING TWO LANES OF TRAFFIC, HIT A CURB, AND FLIPPED OVER IN THE CHAIR.
Patient problems: Bone Fracture(s)
MAUDE report 7508016 ↗MalfunctionMar 28, 2018Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
DEALER ALLEGES BALL JOINT SNAPPED WHEN USER LEANED OVER ON JOYSTICK TO GRAB SOMETHING, USER FELL ON THE FLOOR. FIRE DEPARTMENT RESPONDED TO HELP USER GET UP.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7378619 ↗InjuryJan 23, 2018Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ALLEGES LEAVING DOCTOR'S OFFICE, THE ROADS WERE WET FROM SNOW, AND SHE WAS ON HER WAY OUT OF THE PARKING LOT WHEN THE UNIT SEEMED OFF BALANCE, SHE MIGHT HAVE HIT A ROCK, WHEN THE UNIT TIPPED TO THE LEFT. SHE CLAIMS SHE HIT THE ARMREST WITH HER RIBS AND THE UNIT FELL ON HER. ALLEGES HAD TO BEND A BRACKET TO GET UNIT OFF OF HER.
Patient problems: Bruise/Contusion
MAUDE report 7213261 ↗
FDA clearance and classification
The FDA regulates product code ITI (wheelchair, powered) under 21 CFR 890.3860 as a Class II device. 21 CFR 890.3860 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
FDA definition of this device type: A powered wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position. FDA interprets mobility to persons restricted to a sitting position to mean the device type is intended to provide mobility to individuals who have mobility impairments and require an assistive device for mobility. NOTE: This type of device is not intended to climb stairs (see product code: IMK).
Common questions about the Q6 Edge Q6 Edge/Q4/J623/Q623/Q6 Edge RQ/Q6 Edge X
Has the Q6 Edge Q6 Edge/Q4/J623/Q623/Q6 Edge RQ/Q6 Edge X been recalled?
No FDA recall record in our data names this exact device identifier (DI 00606509200028), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Q6 Edge Q6 Edge/Q4/J623/Q623/Q6 Edge RQ/Q6 Edge X?
The FDA's MAUDE database lists 9 adverse event reports for this device, received between Jan 23, 2018 and Jul 19, 2021. In those reports, the most common patient problems are “Bone Fracture(s)” (2), “Bruise/Contusion” (2) and “Eye Injury” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Q6 Edge Q6 Edge/Q4/J623/Q623/Q6 Edge RQ/Q6 Edge X?
None of the reports are classified as deaths, 8 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Q6 Edge Q6 Edge/Q4/J623/Q623/Q6 Edge RQ/Q6 Edge X, and is it still sold?
The FDA's device database lists Pride Mobility Products Corp as the company responsible for it (brand Q6 Edge, model Q6 Edge/Q4/J623/Q623/Q6 Edge RQ/Q6 Edge X). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Wheelchair, Powered devices
- SmartDrive® MX2+Max Mobility, LLC · Wheelchair, Powered858 reports
- Permobil M3Permobil, Inc. · Wheelchair, Powered1 recall60 reports
- TDX SP2 Base for Multiple Actuator System w/ Ultra Low Maxx TDXSP2-MCGInvacare Corporation · Wheelchair, powered2 recalls2 reports
- TDX SP2 with LiNX Electronics TDXSP2Invacare Corporation · Wheelchair, powered2 recalls0 reports
- Invacare® TDX SP2 with Captain's Seat TDXSP2VInvacare Corporation · Wheelchair, powered2 recalls0 reports
- Q6 Edge 3Pride Mobility Products Corp · Wheelchair, Powered4 deaths87 reports
- Q6 Edge 2.0 Q6 Edge 2.0 / Q6 Edge 2.0 with iLevelPride Mobility Products Corp · Wheelchair, Powered1 death83 reports
- Permobil M5Permobil, Inc. · Wheelchair, Powered1 recall7 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record