Parker H-PFNC-65Recalls & reported problems
Salter Labs · Endotracheal Tube, Preformed Nasal, High Volume Low Pressure, Cuffed (PFNC), Parker, 6.5mm Parker Original DID: 10749065031655. · Class 2
All models of Parker (13)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00607411954429), received between Jul 3, 2025 and Oct 29, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Material Integrity Problem” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Material Integrity Problem3
Patient problems
- Skin Inflammation/ Irritation3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 29, 2025Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED THAT DURING INTUBATION, THERE WAS RESISTANCE. UPON EXAMINATION WITH A VIDEO LARYNGOSCOPE, BLEEDING WAS OBSERVED. IT APPEARED DIFFICULT TO PASS THE ENDOSCOPE THROUGH THE POSTERIOR PHARYNGEAL WALL, WHICH RESULTED IN MUCOSAL DAMAGE THE TUBE WAS REMOVED, AND ORAL INTUBATION WAS PERFORMED. THIS INCIDENT CAUSED A DELAY IN INTUBATION, PATIENT THERAPY, AND HARM TO THE PATIENT.
Patient problems: Skin Inflammation/ Irritation
MAUDE report 23419260 ↗MalfunctionJul 3, 2025Material Integrity Problem; Material Integrity Problem
SUNMED HOLDINGS LLC. RECEIVED A SINGLE REPORT THAT REFERENCED THREE DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING THREE DIFFERENT PATIENTS. THIS IS THE THIRD OF THREE REPORTS. REFER TO 3004748541-2025-00023 FOR THE FIRST REPORT REFER TO 3004748541-2025-00024 FOR THE SECOND REPORT . REFER TO . FOR THE THIRD REPORT . IT WAS REPORTED, A NOSEBLEED OCCURRED IMMEDIATELY AFTER THE START OF USE. THERE WAS NO REPORT OF MEDICAL INTERVENTION.
Patient problems: Skin Inflammation/ Irritation
MAUDE report 22401209 ↗MalfunctionJul 3, 2025Material Integrity Problem; Material Integrity Problem
SUNMED HOLDINGS LLC. RECEIVED A SINGLE REPORT THAT REFERENCED THREE DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING THREE DIFFERENT PATIENTS. THIS IS THE FIRST OF THREE REPORTS. REFER TO 3004748541-2025-00024 FOR THE SECOND REPORT REFER TO 3004748541-2025-00025 FOR THE THIRD REPORT . IT WAS REPORTED, A NOSEBLEED OCCURRED IMMEDIATELY AFTER THE START OF USE. THERE WAS NO REPORT OF MEDICAL INTERVENTION.
Patient problems: Skin Inflammation/ Irritation
MAUDE report 22401208 ↗
Other Tube, Tracheal (W/Wo Connector) devices
- Shiley 18875Covidien LP · Tube, tracheal (w/wo connector)4 deaths570 reports
- RUSCH IPN041476Teleflex Incorporated · Tube, tracheal (w/wo connector)10 recalls0 reports
- Shiley 18775Covidien LP · Tube, tracheal (w/wo connector)489 reports
- Shiley 18770Covidien LP · Tube, tracheal (w/wo connector)2 deaths434 reports
- Shiley 18880Covidien LP · Tube, tracheal (w/wo connector)2 deaths370 reports
- Shiley 18780Covidien LP · Tube, tracheal (w/wo connector)3 deaths286 reports
- Shiley 18770SCovidien LP · Tube, tracheal (w/wo connector)273 reports
- Shiley 18780SCovidien LP · Tube, tracheal (w/wo connector)251 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page