Stealth® Spring Clip A1604Recalls & reported problems

Applied Medical Resources Corporation · 3/4 Force Surgical Spring Clip · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00607915113902), received between May 14, 2025 and May 14, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Device Slipped” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Slipped1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 14, 2025Device Slipped; Device Slipped

    TYPE OF PROCEDURE: [AV FISTULA]. EVENT DESCRIPTION: [DURING THE AV FISTULA CREATION, [DOCTOR] APPLIED THE SOFT/SOFT CLIP, TO THE BRACHIAL ARTERY FOR OCCLUSION. HOWEVER, IT SLIPPED OFF DUE TO INSUFFICIENT TRACTION OF THE PAD SURFACE TO THE ARTERY PER HIS FEEDBACK. THE VESSEL WAS NOT DAMAGED. PATIENT IS FINE. [DOCTOR] LIKED THE LATIS/LATIS AND FIBRA OPTIONS HE USED.] PATIENT STATUS: [PATIENT IS FINE]. INTERVENTION: [USAGE OF A CLIP WITH A DIFFERENT PAD, SUCH AS SOFT/FIBRA.]

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22020204 ↗

FDA clearance and classification

The FDA regulates product code DSS (clip, vascular) under 21 CFR 870.3250 as a Class II device. 21 CFR 870.3250 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Stealth® Spring Clip A1604

Has the Stealth® Spring Clip A1604 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00607915113902), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Stealth® Spring Clip A1604?

The FDA's MAUDE database lists 1 adverse event report for this device, received on May 14, 2025. That report lists device problem “Device Slipped” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Stealth® Spring Clip A1604?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the Stealth® Spring Clip A1604, and is it still sold?

The FDA's device database lists Applied Medical Resources Corporation as the company responsible for it (brand Stealth® Spring Clip, model A1604). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Clip, Vascular devices

All Clip, Vascular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page