Applied Medical Resources Corporation · Indicated for surgical clamping during cardiovascular peripheral vascular, and general surgery. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00607915118013), received between Jun 18, 2025 and Jun 18, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Difficult to Open or Close” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Open or Close1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 18, 2025Difficult to Open or Close; Difficult to Open or Close

    PROCEDURE: KIDNEY TRANSPLANT EVENT DESCRIPTION: [HOSPITAL NAME] MODEL #: G-6050, LOT #: 1533455. SUMMARY: DURING THE CASE, THE ATTENDING PHYSICIAN DECIDED TO "BACKFILL" THE TRANSPLANTED KIDNEY. IN ORDER TO PERFORM THIS, THEY USED A SPRING CLIP, WHICH WAS PASSED TO THE ATTENDING ON A SPRING CLIP LOADER. THE SPRING CLIP WAS SUCCESSFULLY PLACED ON THE PATIENT'S KIDNEY, AND THEN THE ATTENDING USED PAPAVERINE, A MEDICATION, IN ADDITION. AFTER THIS WAS USED, THE SPRING CLIP WAS REMOVED, AT WHICH TIME THE DEVICE BROKE INTO TWO SEPARATE PIECES. THE DEVICE WAS SEQUESTERED, AND THEN PASSED OFF THE FIELD. THE LOT NUMBER FOR THE DEVICE IS AS FOLLOWS: 1533455. THIS LOT NUMBER AND EXPIRATION DATE WERE CONFIRMED TO MATCH BOTH SPRING CLIPS WHICH WERE OPENED FOR THE CASE. ADDITIONAL INFORMATION PROVIDED ON 17FEB2025 NO INTERVENTION WAS USED TO COMPLETE THE PROCEDURE WHEN THE DEVICE MALFUNCTIONED. THE DEVICE FAILED AT THE END OF THE CASE. NO, THE SURGEON DID NOT EXPERIENCE LOSS OF OCCLUSION DUE TO JAW SEPARATION. THE SEPARATION HAPPENED DURING THE PLANNED UNCLAMPING. THERE WAS NO DAMAGE TO THE VESSEL. THERE WAS NO RUST NOTED AFTER THE DEVICE SEPARATED. PATIENT STATUS: NO HARM INTERVENTION: NI.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22287101 ↗