Skip to content

New Image 16104Recalls & reported problems

Hollister Incorporated · 2-Piece Ostomy Skin Barrier, Flextend · Class 1

All models of New Image (19)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00610075112937), received between Mar 19, 2024 and Mar 19, 2024 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Hypersensitivity/Allergic reaction1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 19, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT OVER A YEAR AGO AN END USER EXPERIENCED SKIN IRRITATION UNDER THE TAPE BORDER OF THE HOLLISTER 16104 NEW IMAGE OSTOMY BARRIER. THE END USER REPORT THAT AT THAT TIME HE WAS PRESCRIBED CLOBETASOL CREAM BY HIS HEALTH CARE PROFESSIONAL. HE FURTHER REPORTED THAT THE CREAM CLEARED UP THE IRRITATION AND NOW HE IS SAMPLING BARRIERS WITHOUT THE TAPE BORDER.

    Patient problems: Hypersensitivity/Allergic reaction

    MAUDE report 18935347 ↗

Other COLLECTOR, OSTOMY devices

All COLLECTOR, OSTOMY devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page