Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00613994486257), received between Jun 1, 2017 and Jun 1, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Device Remains Activated” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device Remains Activated1
Patient problems
- Cerebrospinal Fluid Leakage1
- Perforation1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 1, 2017Device Remains Activated; Device Remains Activated
IT WAS REPORTED THAT THE MOTOR DID NOT STOP SPINNING WHEN THE SURGEON TOOK THE HAND OFF THE HAND CONTROL. THE PATIENT HAD A DURA TEAR, BECAUSE THE MOTOR WOULD NOT STOP SPINNING. ON FOLLOW UP, IT WAS REPORTED THE PATIENT WAS REQUIRED TO STAY OVERNIGHT DUE TO THE CSF LEAK AND FOR MONITORING. THE PATIENT HAS SINCE BEEN DISCHARGED, BUT THE CURRENT CONDITION IS UNKNOWN. THERE WAS NO ADDITIONAL PATIENT INFORMATION AVAILABLE. THE SURGICAL PROCEDURE WAS A LAMINOTOMY (SPINAL SURGERY - NO FUSION). THE INITIAL REPORTER INFORMATION AND PARTIAL CONCOMITANT DEVICE INFORMATION WAS ALSO PROVIDED. ON FURTHER FOLLOW UP WITH THE DOCTOR, IT WAS REPORTED THE PATIENT WAS WELL POSTOPERATIVE. THE DURA LEAK WAS ADDRESSED WITH NO PATCH USED.
Patient problems: Cerebrospinal Fluid Leakage; Perforation
MAUDE report 6606343 ↗
Other MOTOR, DRILL, PNEUMATIC devices
- NA 05.001.080Synthes GmbH · MOTOR, DRILL, PNEUMATIC432 reports
- NA CSR60Synthes GmbH · MOTOR, DRILL, PNEUMATIC221 reports
- Midas Rex® AF02Medtronic Powered Surgical Solutions · MOTOR, DRILL, PNEUMATIC163 reports
- Maestro Air 5407-200-000Stryker Corporation · MOTOR, DRILL, PNEUMATIC112 reports
- Maestro 5400210060Stryker Corporation · MOTOR, DRILL, PNEUMATIC95 reports
- MIDAS REX™ AF02Medtronic Powered Surgical Solutions · MOTOR, DRILL, PNEUMATIC91 reports
- CORE, Maestro 5400200000Stryker Corporation · MOTOR, DRILL, PNEUMATIC75 reports
- Maestro Air 5407-200-00HStryker Corporation · MOTOR, DRILL, PNEUMATIC56 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page